Experimental and simulation studies on air source heat pump water heater for year-round applications in Canada

被引:35
|
作者
Amirirad, Afarin [1 ]
Kumar, Rakesh [1 ]
Fung, Alan S. [1 ]
Leong, Wey H. [1 ]
机构
[1] Ryerson Univ, Dept Mech & Ind Engn, 350 Victoria St, Toronto, ON M5B 2K3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Air source heat pump water heater; Sustainable house; Experimental data; Coefficient of performance; TRNSYS simulation; Energy saving; PERFORMANCE; SYSTEM;
D O I
10.1016/j.enbuild.2018.01.052
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The performance of a new type of Air Source Heat Pump Water Heater (ASHPWH) has been investigated. ASHPWH has a better performance than the conventional electric water heater if it is installed in a hotter climate. However, the conditions are different in Canada, where outside air temperature is well below the freezing point for several months, and that diminishes the water heating capacity of these systems significantly. On the other hand, if it is installed in the indoor space (which is the case of this research), the presence of the system in the house affects the house heating and cooling loads. Therefore, an understanding of energy performance of this types water heaters is critical to justify their use in the Canadian houses. The research methodology involved, installation of the ASHPWH unit in an Archetype Sustainable House (ASH), reconfiguration of some parts of house plumbing system, build sensors and data acquisition system to collect real-time experimental data, developed and validated TRNSYS models. Furthermore, the validated models were applied to evaluate the performance of the unit to meet the year-round hot water demand and established its significance with respect to the conventional electric water heater. It was concluded that the temperature and humidity of surrounding air produced a considerable impact on the heating capacity of the ASHPWH. The best coefficient of performance (COP) was obtained at 20 degrees C and 35% RH from the chosen sets of air conditions. The outlet water temperature fluctuates in the range of 49.5 degrees C to 55.9 degrees C (while the setpoint temperature was taken at 54 degrees C). The system will increase the combined space heating and cooling electricity consumptions annually by 3%, on the other hand, a reduction of 55% of water heater related annual electricity consumption was noted relative to the conventional electric water heater. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:141 / 149
页数:9
相关论文
共 50 条
  • [1] Performance characterization of an indoor air source heat pump water heater for residential applications in Canada
    Amirirad, Afarin
    Kumar, Rakesh
    Fung, Alan S.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2018, 42 (03) : 1316 - 1327
  • [2] AN EXPERIMENTAL ANALYSIS OF AIR SOURCE HEAT PUMP WATER HEATER
    Ozturk, M. Mete
    Erbay, L. Berrin
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2012, 32 (01) : 117 - 127
  • [3] Experimental study of a control strategy for a cascade air source heat pump water heater
    Qu Minglu
    Fan Yanan
    Chen Jianbo
    Li Tianrui
    Li Zhao
    Li He
    APPLIED THERMAL ENGINEERING, 2017, 110 : 835 - 843
  • [4] Experimental and numerical study on transcritical CO2 air source heat pump water heater
    Li, Yifan
    Li, Mengxi
    Yang, Junlan
    APPLIED THERMAL ENGINEERING, 2025, 258
  • [5] EXPERIMENTAL RESEARCH ON DYNAMIC PERFORMANCE OF AN AIR/WATER SOURCE HEAT PUMP WATER HEATER
    Qiu, Fuqiang
    Du, Juanli
    Wang, Yu
    Zhang, Xingwei
    Yu, Changsuo
    Nan, Yun
    THERMAL SCIENCE, 2024, 28 (3A): : 2067 - 2074
  • [6] Experimental research of an air-source heat pump water heater using water-PCM for heat storage
    Zou, Deqiu
    Ma, Xianfeng
    Liu, Xiaoshi
    Zheng, Pengjun
    Cai, Baiming
    Huang, Jianfeng
    Guo, Jiangrong
    Liu, Mo
    APPLIED ENERGY, 2017, 206 : 784 - 792
  • [7] Residential Air Source Heat Pump Water Heater Performance Testing and Feasibility Analysis in Cold Climate
    Tung, King
    Kumar, Rakesh
    Fung, Alan S.
    Leong, Wey H.
    SUSTAINABILITY, 2025, 17 (05)
  • [8] Experimental research and operation optimization of an air-source heat pump water heater
    Guo, J. J.
    Wu, J. Y.
    Wang, R. Z.
    Li, S.
    APPLIED ENERGY, 2011, 88 (11) : 4128 - 4138
  • [9] Experimental Research of Performance on Dual Source Heat Pump Water Heater Using Air and Water
    Zhu, Xingwang
    Nie, Xueli
    Guo, Zhi-min
    Su, Yugui
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [10] STUDY ON PERFORMANCE OF AIR SOURCE HEAT PUMP WATER HEATER
    Duan, Rui
    PROGRESS IN RENEWABLE AND SUSTAINABLE ENERGY, PTS 1 AND 2, 2013, 608-609 : 987 - 993