In vitro evaluation of the implant abutment connection sealing capability of different implant systems

被引:85
作者
Coelho, P. G. [1 ]
Sudack, P. [1 ]
Suzuki, M. [2 ]
Kurtz, K. S. [3 ,4 ]
Romanos, G. E. [5 ]
Silva, N. R. F. A. [1 ]
机构
[1] NYU, Coll Dent, Dept Biomat & Biomimet, New York, NY 10010 USA
[2] Tufts Sch Dent Med, Dept Prosthodont & Operat Dent, Boston, MA USA
[3] Montefiore Med Ctr, Albert Einstein Coll Med, Dept Dent, Bronx, NY 10467 USA
[4] Montefiore Med Ctr, Albert Einstein Coll Med, Dept Otolaryngol, Bronx, NY 10467 USA
[5] Univ Rochester, Sch Med & Dent, Dept Periodontol, Rochester, NY USA
关键词
dental implant; implant connection; implant-abutment gap; microleakage; in vitro; spectophotometry;
D O I
10.1111/j.1365-2842.2008.01886.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study sought to evaluate the sealing capability of the implant abutment connection of different dental implant systems. Five Nobel Replace select, Straumann and Intra-lock implants of approximately 4.5 mm diameter with their respective abutments were provided by the manufacturers. A calibration curve was determined by placing toluidine blue (TB) increments of 0.1 mu L into 1.5 mL of distilled water and recording its absorbance in a spectrophotometer until reaching 0.7 mu L. Then, 0.7 mu L of TB was placed in the deepest portion of each implant's internal screw, the abutments were adapted to the implant according to the manufacturer's instructions and the specimens were placed in vials with 1.5 mL of distilled water. Spectrophotometric analysis was performed at 1, 3, 6, 24, 48, 72, 96 and 144 h. Statistical analysis was performed by One-way anova at 95% level of significance. The calibration curve was linear with respect to the TB amount in 1.5 mu L distilled water (R-2 = 0.9961). All implant abutment systems presented an increase in absorbance as a function of time. As time elapsed in vitro, significantly higher amounts of TB was released from the Straumann and Nobel Replace Select connection systems (P < 0.0001). Leakage was significant between the groups. Despite controlled torquing, the seal between the implant body and the abutment could not be maintained in all three of the systems tested.
引用
收藏
页码:917 / 924
页数:8
相关论文
共 50 条
[1]   MARGINAL TISSUE-REACTIONS AT OSSEOINTEGRATED TITANIUM FIXTURES .1. A 3-YEAR LONGITUDINAL PROSPECTIVE-STUDY [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI ;
LINDHE, J ;
ERIKSSON, B ;
SBORDONE, L .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1986, 15 (01) :39-52
[2]  
Al-Turki LEE, 2002, INT J PROSTHODONT, V15, P38
[3]   Influence of occlusal forces on stress distribution in preloaded dental implant screws [J].
Alkan, I ;
Sertgöz, A ;
Ekici, E .
JOURNAL OF PROSTHETIC DENTISTRY, 2004, 91 (04) :319-325
[4]  
Becker W, 1991, Quintessenz, V42, P9
[5]  
Behneke A, 2000, INT J ORAL MAX IMPL, V15, P125
[6]  
Bickford JH, 1981, INTRO DESIGN BEHAV B, P528
[7]   Evaluation of the effectiveness of a technique to prevent screw loosening [J].
Binon, PP .
JOURNAL OF PROSTHETIC DENTISTRY, 1998, 79 (04) :430-432
[8]  
Binon PP, 1996, INT J PROSTHODONT, V9, P149
[9]   Mechanics of the tapered interference fit in dental implants [J].
Bozkaya, D ;
Müftü, S .
JOURNAL OF BIOMECHANICS, 2003, 36 (11) :1649-1658
[10]  
Branemark P I, 1977, Scand J Plast Reconstr Surg Suppl, V16, P1