Controlled attenuation parameter value-based diagnostic algorithm improves the accuracy of liver stiffness measurement in chronic hepatitis B patients

被引:4
|
作者
Fan, Yaoxin [1 ]
Wang, Lin [2 ]
Ding, Yang [1 ]
Sheng, Qiuju [1 ]
Zhang, Chong [1 ]
Li, Yanwei [1 ]
Han, Chao [1 ]
Dou, Xiaoguang [1 ]
机构
[1] China Med Univ, Shengjing Hosp, Dept Infect Dis, Shenyang, Liaoning, Peoples R China
[2] China Med Univ, Shengjing Hosp, Dept Hlth Management, Shenyang, Liaoning, Peoples R China
来源
AGING-US | 2020年 / 12卷 / 16期
关键词
diagnostic algorithm; liver fibrosis measurement; chronic hepatitis B; controlled attenuation parameter; METABOLIC SYNDROME INCREASES; TRANSIENT ELASTOGRAPHY; FIBROSIS; STEATOSIS; DISEASE; VIRUS; COHORT;
D O I
10.18632/aging.103522
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Liver stiffness measurement (LSM) frequently overestimates the severity of liver fibrosis because of steatosis. However, the impact of the controlled attenuation parameter (CAP) on liver stiffness cutoff values remains unknown; CAP was used to quantify and diagnose the severity of hepatic steatosis. The study was conducted to determine the effect of CAP on liver stiffness cutoff values in chronic hepatitis B (CHB) patients. A retrospective cross-sectional study was performed in liver biopsy-proven CHB patients. The median LSM (kPa) in the elevated CAP group was higher than that in the normal CAP group at the same fibrosis stage. For S2-4, the area under the receiver operating characteristic (AUROC) curve of LSM was 0.78 and 0.72 in the normal and elevated CAP groups, respectively. When a cutoff value of 8.9 kPa was used, the diagnostic accuracy was 77.82% and 63.41% in the normal and elevated CAP groups, respectively. Compared with the alanine transaminase (ALT)-based LSM algorithm, the CAP-based LSM algorithm had a similar correct diagnosis rate (33.64% vs. 33.94%, respectively) but a lower misdiagnosis rate (16.97% vs. 20.30%, respectively). The new CAP-based LSM diagnostic algorithm will improve the diagnostic accuracy of liver fibrosis in CHB patients.
引用
收藏
页码:16072 / 16082
页数:11
相关论文
共 50 条
  • [31] Ultrasound-Based Liver Stiffness Surveillance in Patients Treated for Chronic Hepatitis B or C
    Chen, Sheng-Hung
    Peng, Cheng-Yuan
    APPLIED SCIENCES-BASEL, 2018, 8 (04):
  • [32] The change in liver stiffness, controlled attenuation parameter and fibrosis-4 index for chronic hepatitis C patients with direct-acting antivirals
    Lee, Yu-Chi
    Hu, Tsung-Hui
    Hung, Chao-Hung
    Lu, Sheng-Nan
    Chen, Chien-Hung
    Wang, Jing-Houng
    PLOS ONE, 2019, 14 (04):
  • [33] Serial changes in liver stiffness and controlled attenuation parameter following direct-acting antiviral therapy against hepatitis C virus genotype 1b
    Ogasawara, Nobuhiko
    Kobayashi, Masahiro
    Akuta, Norio
    Kominami, Yoko
    Fujiyama, Shunichiro
    Kawamura, Yusuke
    Sezaki, Hitomi
    Hosaka, Tetsuya
    Suzuki, Fumitaka
    Saitoh, Satoshi
    Suzuki, Yoshiyuki
    Arase, Yasuji
    Ikeda, Kenji
    Kobayashi, Mariko
    Kumada, Hiromitsu
    JOURNAL OF MEDICAL VIROLOGY, 2018, 90 (02) : 313 - 319
  • [34] Probability-Based Interpretation of Liver Stiffness Measurement in Untreated Chronic Hepatitis B Patients
    Vincent Wai-Sun Wong
    Pietro Lampertico
    Victor de Lédinghen
    Pik Eu Chang
    Seung Up Kim
    Yongpeng Chen
    Henry Lik-Yuen Chan
    Giampaolo Mangia
    Juliette Foucher
    Wan Cheng Chow
    Sang Hoon Ahn
    Jinlin Hou
    Digestive Diseases and Sciences, 2015, 60 : 1448 - 1456
  • [35] The Diagnostic Value of FibroScan in Assessing Significant Liver Fibrosis in Patients with Chronic Hepatitis B
    Zeng, X.
    Xu, C.
    Li, M.
    Xia, J.
    Liu, M.
    Zhu, P.
    Xiang, D.
    Wang, Y.
    WEST INDIAN MEDICAL JOURNAL, 2016, 65 (01) : 106 - 110
  • [36] Liver stiffness measurement trajectory analysis for prognosis in patients with chronic hepatitis B and compensated advanced chronic liver disease
    Jiang, Hao
    Yu, Hongsheng
    Hu, Can
    Huang, Yinan
    Yang, Bilan
    Xi, Xiaoli
    Lei, Yiming
    Wu, Bin
    Yang, Yidong
    ANNALS OF HEPATOLOGY, 2025, 30 (01)
  • [37] Optimal Time for Restoring the Reliability of Liver Stiffness Measurement in Patients With Chronic Hepatitis B Experiencing Acute Exacerbation
    Park, Hana
    Kim, Seung Up
    Kim, Darae
    Kim, Do Young
    Ahn, Sang Hoon
    Han, Kwang-Hyub
    Chon, Chae Yoon
    Park, Jun Yong
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2012, 46 (07) : 602 - 607
  • [38] Usefulness of controlled attenuation parameter and liver stiffness measurement for detecting increased arterial stiffness in asymptomatic populations in China
    Yu, Xin-Yan
    Song, Xiao-Xiao
    Tong, Yu-Ling
    Wu, Ling-Yan
    Song, Zhen-Ya
    MEDICINE, 2020, 99 (48) : E23360
  • [39] A comparison of hepatic steatosis index, controlled attenuation parameter and ultrasound as noninvasive diagnostic tools for steatosis in chronic hepatitis B
    Xu, Liang
    Lu, Wei
    Li, Ping
    Shen, Feng
    Mi, Yu-Qiang
    Fan, Jian-Gao
    DIGESTIVE AND LIVER DISEASE, 2017, 49 (08) : 910 - 917
  • [40] Factors Affecting the Accuracy of Controlled Attenuation Parameter (CAP) in Assessing Hepatic Steatosis in Patients with Chronic Liver Disease
    Jung, Kyu Sik
    Kim, Beom Kyung
    Kim, Seung Up
    Chon, Young Eun
    Cheon, Kyung Hyun
    Kim, Sung Bae
    Lee, Sang Hoon
    Ahn, Sung Soo
    Park, Jun Yong
    Kim, Do Young
    Ahn, Sang Hoon
    Park, Young Nyun
    Han, Kwang-Hyub
    PLOS ONE, 2014, 9 (06):