Controlled attenuation parameter value-based diagnostic algorithm improves the accuracy of liver stiffness measurement in chronic hepatitis B patients

被引:4
|
作者
Fan, Yaoxin [1 ]
Wang, Lin [2 ]
Ding, Yang [1 ]
Sheng, Qiuju [1 ]
Zhang, Chong [1 ]
Li, Yanwei [1 ]
Han, Chao [1 ]
Dou, Xiaoguang [1 ]
机构
[1] China Med Univ, Shengjing Hosp, Dept Infect Dis, Shenyang, Liaoning, Peoples R China
[2] China Med Univ, Shengjing Hosp, Dept Hlth Management, Shenyang, Liaoning, Peoples R China
来源
AGING-US | 2020年 / 12卷 / 16期
关键词
diagnostic algorithm; liver fibrosis measurement; chronic hepatitis B; controlled attenuation parameter; METABOLIC SYNDROME INCREASES; TRANSIENT ELASTOGRAPHY; FIBROSIS; STEATOSIS; DISEASE; VIRUS; COHORT;
D O I
10.18632/aging.103522
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Liver stiffness measurement (LSM) frequently overestimates the severity of liver fibrosis because of steatosis. However, the impact of the controlled attenuation parameter (CAP) on liver stiffness cutoff values remains unknown; CAP was used to quantify and diagnose the severity of hepatic steatosis. The study was conducted to determine the effect of CAP on liver stiffness cutoff values in chronic hepatitis B (CHB) patients. A retrospective cross-sectional study was performed in liver biopsy-proven CHB patients. The median LSM (kPa) in the elevated CAP group was higher than that in the normal CAP group at the same fibrosis stage. For S2-4, the area under the receiver operating characteristic (AUROC) curve of LSM was 0.78 and 0.72 in the normal and elevated CAP groups, respectively. When a cutoff value of 8.9 kPa was used, the diagnostic accuracy was 77.82% and 63.41% in the normal and elevated CAP groups, respectively. Compared with the alanine transaminase (ALT)-based LSM algorithm, the CAP-based LSM algorithm had a similar correct diagnosis rate (33.64% vs. 33.94%, respectively) but a lower misdiagnosis rate (16.97% vs. 20.30%, respectively). The new CAP-based LSM diagnostic algorithm will improve the diagnostic accuracy of liver fibrosis in CHB patients.
引用
收藏
页码:16072 / 16082
页数:11
相关论文
共 50 条
  • [1] Diagnostic value of controlled attenuation parameter for liver steatosis in patients with chronic hepatitis B
    Wang, Chun-Yan
    Lu, Wei
    Hu, Dong-Sheng
    Wang, Guang-Dong
    Cheng, Xiao-Jing
    WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (30) : 10585 - 10590
  • [2] A diagnostic algorithm for assessment of liver fibrosis by liver stiffness measurement in patients with chronic hepatitis B
    Cai, Y. -J.
    Dong, J. -J.
    Wang, X. -D.
    Huang, S. -S.
    Chen, R. -C.
    Chen, Y.
    Wang, Y. -Q.
    Song, M.
    Chen, Y. -P.
    Li, Z.
    Zhou, M. -T.
    Shi, K. -Q.
    JOURNAL OF VIRAL HEPATITIS, 2017, 24 (11) : 1005 - 1015
  • [3] Diagnostic value of controlled attenuation parameter for liver steatosis in patients with chronic hepatitis B
    Chun-Yan Wang
    Wei Lu
    Dong-Sheng Hu
    Guang-Dong Wang
    Xiao-Jing Cheng
    World Journal of Gastroenterology, 2014, (30) : 10585 - 10590
  • [4] Controlled attenuation parameter value and the risk of hepatocellular carcinoma in chronic hepatitis B patients under antiviral therapy
    Oh, Joo Hyun
    Lee, Hye Won
    Sinn, Dong Hyun
    Park, Jun Yong
    Kim, Beom Kyung
    Kim, Seung Up
    Kim, Do Young
    Ahn, Sang Hoon
    Kang, Wonseok
    Gwak, Geum-Youn
    Choi, Moon Seok
    Lee, Joon Hyeok
    Koh, Kwang Cheol
    Paik, Seung Woon
    Paik, Yong-Han
    HEPATOLOGY INTERNATIONAL, 2021, 15 (04) : 892 - 900
  • [5] ACCURACY OF CONTROLLED ATTENUATION PARAMETER AND LIVER STIFFNESS MEASUREMENT IN PATIENTS WITH NON-ALCOHOLIC FATTY LIVER DISEASE
    Mikolasevic, Ivana
    Domislovic, Viktor
    Klapan, Mia
    Juric, Toni
    Lukic, Andjela
    Krznaric-Zrnic, Irena
    Fuckar-Cupic, Dora
    Stimac, Davor
    Kanizaj, Tajana Filipec
    Krznaric, Zeljko
    Radic-Kristo, Delfa
    Milic, Sandra
    Martinovic, Marko
    Grubesic, Aron
    Grgurevic, Ivica
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (03) : 428 - 437
  • [6] Dynamic evaluation of liver stiffness measurement to improve diagnostic accuracy of liver cirrhosis in patients with chronic hepatitis B acute exacerbation
    Liang, X. -E
    Chen, Y. -P.
    Zhang, Q.
    Dai, L.
    Zhu, Y. -F.
    Hou, J. -L.
    JOURNAL OF VIRAL HEPATITIS, 2011, 18 (12) : 884 - 891
  • [7] The Impact of Steatosis on Liver Stiffness Measurement in Patients with Chronic Hepatitis B
    Kim, Seung Up
    Kim, Do Young
    Ahn, Sang Hoon
    Kim, Hee Man
    Lee, Jung Min
    Chon, Chae Yoon
    Park, Young Nyun
    Han, Kwang-Hyub
    Park, Jun Yong
    HEPATO-GASTROENTEROLOGY, 2010, 57 (101) : 832 - 838
  • [8] Probability-Based Interpretation of Liver Stiffness Measurement in Untreated Chronic Hepatitis B Patients
    Wong, Vincent Wai-Sun
    Lampertico, Pietro
    de Ledinghen, Victor
    Chang, Pik Eu
    Kim, Seung Up
    Chen, Yongpeng
    Chan, Henry Lik-Yuen
    Mangia, Giampaolo
    Foucher, Juliette
    Chow, Wan Cheng
    Ahn, Sang Hoon
    Hou, Jinlin
    DIGESTIVE DISEASES AND SCIENCES, 2015, 60 (05) : 1448 - 1456
  • [9] Controlled attenuation parameter for evaluating liver steatosis in chronic viral hepatitis
    Ferraioli, Giovanna
    Tinelli, Carmine
    Lissandrin, Raffaella
    Zicchetti, Mabel
    Dal Bello, Barbara
    Filice, Gaetano
    Filice, Carlo
    WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (21) : 6626 - 6631
  • [10] Clinical outcomes and management of patients with chronic hepatitis B and liver stiffness measurement in the grey zone
    Liu, Ken
    Wong, Vincent W. S.
    Liang, Lilian Y.
    Lui, Grace C. Y.
    Chan, Henry L. Y.
    Wong, Grace L. H.
    LIVER INTERNATIONAL, 2019, 39 (03) : 494 - 502