Transesophageal echocardiographic predictors for maintenance of sinus rhythm after electrical cardioversion of atrial fibrillation

被引:60
|
作者
Verhorst, PMJ
Kamp, O
Welling, RC
VanEenige, MJ
Visser, CA
机构
[1] Department of Cardiology, Inst. for Cardiovascular Research, Free University Hospital, Amsterdam
[2] Department of Cardiology, Free University Hospital, 1081 HV, Amsterdam
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1997年 / 79卷 / 10期
关键词
D O I
10.1016/S0002-9149(97)00139-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to assess the value of transesophageal echocardiography (TEE) in patients with atrial fibrillation in predicting restoration and maintenance of sinus rhythm after electrical cardioversion. TEE was performed in 62 patients with atrial fibrillation before their first elective cardioversion. Clinical variables evaluated were: age, gender, duration, and etiology of atrial fibrillation. TEE variables included: left atrial (LA) length, width, and size, LA annulus size, as well as presence of LA spontaneous contrast, thrombus and mitral regurgitation, LA appendage size and flow, and left ventricular function. Based on initial outcome of cardioversion, patients were grouped into patients who remained in atrial fibrillation and in whom sinus rhythm was restored. The latter group of patients was followed for 1 year, and grouped into patients who reverted to atrial fibrillation and in whom sinus rhythm was maintained. Successful cardioversion was achieved in 50 of 62 patients (81%). None of the clinical or TEE variables were related to initial outcome. At 1-year follow-up, 29 of 50 patients (58%) who underwent successful cardioversion continued to have sinus rhythm. The following variables were related to maintenance of sinus rhythm: duration of atrial fibrillation (6.7 +/- 7.3 vs 2.0 +/- 2.4 months; p <0.005); LA length (6.2 +/- 0.7 vs. 5.5 +/- 1.0 cm; p <0.008); width (5.1 +/- 0.5 vs. 4.5 +/- 0.7 cm; p <0.002); size (26.4 +/- 5.0 vs 19.8 +/- 6.5 cm(2); p <0.0005); annulus size (4.0 +/- 0.2 vs 3.7 +/- 0.3 cm; p <0.0005); presence of LA spontaneous contrast (13 [62%] vs 4 [14%]; p <0.002), and LA appendage flow (19 +/- 8 vs 36 +/- 15 cm/s; p <0.0005). In multivariate logistic regression analysis, LA annulus size, but especially LA appendage flow, were significantly associated with maintenance of sinus rhythm. Thus, in TEE-guided electrical cardioversion of atrial fibrillation, variables often used to assess thromboembolic risk may also be used to predict I-year outcome of cardioversion. (C) 1997 by Excerpta Medica, Inc.
引用
收藏
页码:1355 / 1359
页数:5
相关论文
共 50 条
  • [1] Echocardiographic predictors of sinus rhythm maintenance after electrical cardioversion of persistent atrial fibrillation
    Fera, MS
    Mazza, A
    Pulignano, G
    Minardi, G
    Manzara, C
    De Lio, L
    Pugliese, M
    Giovannini, E
    EUROPEAN HEART JOURNAL, 2003, 24 : 599 - 599
  • [2] The predictive value of transthoracic echocardiographic variables for sinus rhythm maintenance after electrical cardioversion of atrial fibrillation
    Grundvold, Irene
    Tveit, Arnljot
    Smith, Pal
    Seljeflot, Ingebjorg
    Abdelnoor, Michael
    Arnesen, Harald
    CARDIOLOGY, 2008, 111 (01) : 30 - 35
  • [3] The predictive value of transthoracic echocardiographic variables for sinus rhythm maintenance after electrical cardioversion of atrial fibrillation
    Grundvold, Irene
    Tveit, Amljot
    Smith, Pal
    Seljeflot, Ingebjorg
    Abdelnoor, Michael
    Arnesen, Harald
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 119 : S25 - S26
  • [4] Predictors for maintenance of sinus rhythm after cardioversion in patients with nonvalvular atrial fibrillation
    Ökçün, B
    Yigit, Z
    Küçükoglu, S
    Mutlu, H
    Sansoy, V
    Güzelsoy, D
    Üner, S
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2002, 19 (05): : 351 - 357
  • [5] Systematic analysis of ECG predictors of sinus rhythm maintenance after electrical cardioversion for persistent atrial fibrillation
    Lankveld, Theo
    de Vos, Cees B.
    Limantoro, Ione
    Zeemering, Stef
    Dudink, Elton
    Crijns, Harry J.
    Schotten, Ulrich
    HEART RHYTHM, 2016, 13 (05) : 1020 - 1027
  • [6] DOPPLER ECHOCARDIOGRAPHIC PREDICTORS OF PERSISTENT SINUS RHYTHM AFTER CARDIOVERSION OF ATRIAL-FIBRILLATION
    MERCIER, LA
    DETHY, M
    CHASSAT, C
    ROY, D
    CIRCULATION, 1987, 76 (04) : 191 - 191
  • [7] Transthoracic and transesophageal echocardiographic indices predictive of sinus rhythm maintenance after cardioversion of atrial fibrillation: An echocardiographic study during direct current shock
    De Piccoli, B
    Rigo, F
    Ragazzo, M
    Zuin, G
    Martino, A
    Raviele, A
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (07): : 545 - 552
  • [8] Restoration and maintenance of sinus rhythm after the first elective electrical cardioversion of atrial fibrillation
    Lehto, M
    Kala, R
    EUROPEAN HEART JOURNAL, 2000, 21 : 471 - 471
  • [9] Prevalence and predictors of persistent sinus rhythm after elective electrical cardioversion for atrial fibrillation
    Castrichini, Matteo
    Restivo, Luca
    Fabris, Enrico
    Massa, Laura
    Di Meola, Raffaella
    Beltrame, Daria
    De Luca, Antonio
    Korcova, Renata
    Milo, Marco
    Sinagra, Gianfranco
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2021, 22 (08) : 626 - 630
  • [10] Speckle echocardiographic left atrial strain and stiffness index as predictors of maintenance of sinus rhythm after cardioversion for atrial fibrillation: a prospective study
    Amir Y Shaikh
    Abhishek Maan
    Umar A Khan
    Gerard P Aurigemma
    Jeffrey C Hill
    Jennifer L Kane
    Dennis A Tighe
    Eric Mick
    David D McManus
    Cardiovascular Ultrasound, 10