IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY
|
2017年
关键词:
DC-DC power converter;
reduced-order modeling;
stability;
control bandwidth;
LOADS;
D O I:
暂无
中图分类号:
T [工业技术];
学科分类号:
08 ;
摘要:
Voltage stability is a fundamental issue to be addressed in the future All-Electric Ships (AESs) based on DC distribution. Focusing on a cascade-connected MVDC power system (i.e. a feeder DC-DC converter supplying a load DC-DC converter), the small-signal analysis is the first study to be accomplished for investigating the effect of load converter's control bandwidth on the system stability. Albeit such an evaluation may be performed on the complete fifth order model by determining the Routh-Hurwitz coefficients, a convenient model reduction can simplify this study. In such a way, it is possible to provide an analytical and simple formula for defining the minimum acceptable time constant (i.e. the maximum load converter control bandwidth). Once identified such a minimum time constant, some simulations show how the complete and reduced models work in presence of three different filter arrangements on the load converter side.