Simultaneous irradiation of the breast and regional lymph nodes in prone position using helical tomotherapy

被引:9
作者
Kainz, K. [1 ]
White, J. [1 ]
Chen, G-P [1 ]
Hermand, J. [1 ]
England, M. [1 ]
Li, X. A. [1 ]
机构
[1] Med Coll Wisconsin, Dept Radiat Oncol, Milwaukee, WI 53226 USA
关键词
POSTOPERATIVE PULMONARY COMPLICATIONS; 3-DIMENSIONAL CONFORMAL RADIOTHERAPY; INTENSITY-MODULATED RADIOTHERAPY; CANCER-PATIENTS; SUPINE; PNEUMONITIS; DELIVERY; WHOLE;
D O I
10.1259/bjr/18685881
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: We investigated dosimetric advantages of using helical tomotherapy to simultaneously irradiate the breast and regional lymph nodes for patients positioned prone, and compared tomotherapy plan qualities for the prone position with those previously published for the supine position. Methods: Tomotherapy plans for 11 patients (5 left breast, 6 right) simulated with the involved breast suspended downward were generated. Each target (ipsilateral breast and supraclavicular, axillary and internal mammary chain nodes) was to receive 45 Gy. Results: For targets, V-40.5 >= 99.9% and V-42.8 >= 99.5% for all patients, where V-40.5 and V-42.8 denote the relative target volume receiving at least 40.5 and 42.8 Gy, respectively. The targets' maximum dose was, on average, approximately 49.5 Gy. The mean doses to the contralateral lung and heart were lower for right-breast cases (2.8 Gy lung, 2.7 Gy heart) than for left-breast cases (3.8 Gy lung, 8.7 Gy heart). Mean organ doses to the ipsilateral lung (9.3 Gy) and contralateral breast (2.3 Gy) from the prone breast tomotherapy plans were similar to those reported for conventional radiotherapy techniques. For the left breast with regional nodes, tomotherapy plans for prone-positioned patients yielded lower mean doses to the contralateral breast and heart than previously reported data for tomotherapy plans for supine-positioned patients. Conclusion: Helical tomotherapy with prone breast positioning can simultaneously cover the breast and regional nodes with acceptable uniformity and can provide reduced mean dose to proximal organs at risk compared with tomotherapy with supine position. The similarity of plan quality to existing data for conventional breast radiotherapy indicates that this planning approach is appropriate, and that the risk of secondary tumour formation should not be significantly greater.
引用
收藏
页码:E899 / E905
页数:7
相关论文
共 27 条
  • [11] Helical tomotherapy as a means of delivering accelerated partial breast irradiation
    Hui, SK
    Das, RK
    Kapatoes, J
    Oliviera, G
    Becker, S
    Odau, H
    Fenwick, JD
    Patel, R
    Kuske, R
    Mehta, M
    Paliwal, B
    Mackie, TR
    Fowler, JF
    Welsh, JS
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2004, 3 (06) : 639 - 646
  • [12] Effect of set-up uncertainties on the dose distribution in the match region of supraclavicular and tangential breast fields
    Idzes, MHM
    Holmberg, O
    Mijnheer, BJ
    Huizenga, K
    [J]. RADIOTHERAPY AND ONCOLOGY, 1998, 46 (01) : 91 - 98
  • [13] MVCT-Guided Partial-Breast Irradiation in Prone Position: Daily Setup Uncertainty and Dose Verification
    Kainz, K.
    White, J.
    Li, X.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [14] INVESTIGATION OF HELICAL TOMOTHERAPY FOR PARTIAL-BREAST IRRADIATION OF PRONE-POSITIONED PATIENTS
    Kainz, Kristofer
    White, Julia
    Herman, Joann
    Li, X. Allen
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (01): : 275 - 282
  • [15] A randomised trial of Supine versus Prone breast radiotherapy (SuPr study): Comparing set-up errors and respiratory motion
    Kirby, Anna M.
    Evans, Philip M.
    Helyer, Sarah J.
    Donovan, Ellen M.
    Convery, Helen M.
    Yarnold, John R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 100 (02) : 221 - 226
  • [16] Prone versus supine positioning for whole and partial-breast radiotherapy: A comparison of non-target tissue dosimetry
    Kirby, Anna M.
    Evans, Philip M.
    Donovan, Ellen M.
    Convery, Helen M.
    Haviland, Joanna S.
    Yarnold, John R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 (02) : 178 - 184
  • [17] The helical tomotherapy thread effect
    Kissick, MW
    Fenwick, J
    James, JA
    Jerai, R
    Kapatoes, JM
    Keller, H
    Mackie, TR
    Olivera, G
    Soisson, ET
    [J]. MEDICAL PHYSICS, 2005, 32 (05) : 1414 - 1423
  • [18] Postoperative pulmonary complications after preoperative chemoradiation for esophageal carcinoma: Correlation with pulmonary dose-volume histogram parameters
    Lee, HK
    Vaporciyan, AA
    Cox, JD
    Tucker, SL
    Putnam, JB
    Ajani, JA
    Liao, ZX
    Swisher, SG
    Roth, JA
    Smythe, WR
    Walsh, GL
    Mohan, R
    Liu, HH
    Mooring, D
    Komaki, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (05): : 1317 - 1322
  • [19] TOMOTHERAPY - A NEW CONCEPT FOR THE DELIVERY OF DYNAMIC CONFORMAL RADIOTHERAPY
    MACKIE, TR
    HOLMES, T
    SWERDLOFF, S
    RECKWERDT, P
    DEASY, JO
    YANG, J
    PALIWAL, B
    KINSELLA, T
    [J]. MEDICAL PHYSICS, 1993, 20 (06) : 1709 - 1719
  • [20] Evaluation of image-guided helical tomotherapy for the retreatment of spinal metastases
    Mahan, SL
    Ramsey, CR
    Scaperoth, DD
    Chase, DJ
    Byrne, TE
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (05): : 1576 - 1583