Fatal Neurologic Dysfunction During Continuous-Flow Left Ventricular Assist Device Support

被引:9
|
作者
Kawabori, Masashi
Conyer, Ryan T.
Kurihara, Chitaru
Sugiura, Tadahisa
Civitello, Andrew B.
Frazier, O. H.
Morgan, Jeffrey A.
机构
[1] Baylor Coll Med, Div Cardiothorac Transplantat & Circulatory Suppo, Houston, TX 77030 USA
[2] Texas Heart Inst, Dept Cardiopulm Transplantat, Houston, TX 77025 USA
[3] Texas Heart Inst, Ctr Cardiac Support, Houston, TX 77025 USA
[4] Tokyo Metropolitan Geriatr Hosp, Dept Cardiothorac Surg, Tokyo, Japan
[5] Inst Gerontol, Dept Cardiothorac Surg, Tokyo, Japan
关键词
RISK-FACTORS; STROKE; OUTCOMES; EVENTS; GENDER;
D O I
10.1016/j.athoracsur.2018.10.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. During continuous-flow left ventricular assist device (CF-LVAD) support, neurologic dysfunction (ND) is a common complication and can be fatal. Few reports provide detailed data on neurologic mortality in such patients. Therefore, we examined ND-related mortality during CF-LVAD support. Methods. Between November 2003 and March 2016, 526 patients underwent implantation of a CF-LVAD (403 HeartMate II [Thoratec, Pleasanton, CA] and 123 HVAD [HeartWare International, Framingham, MA]) at our center. We categorized ND as hemorrhagic or ischemic and recorded resulting deaths. Records were reviewed to determine preoperative demographics, perioperative variables, prevalence and causes of postimplantation ND, duration of support until ND, time from ND to death, laboratory data and medications at the time of ND, post-ND treatment procedures, and causes of hemorrhagic ND. We also performed Cox multivariable logistic regression analysis to identify predictors of ND-related mortality by calculating odds ratios and confidence intervals. Results. Neurologic dysfunction occurred in 141 patients (26.8%), 48 (9.1%) of whom subsequently died. Median duration of left ventricular assist device support before ND was 230 days (range, 3 to 2,422), and median time from ND to death was 3.5 days (range, 0 to 55). Parenchymal hemorrhage was the most frequent cause of early conversion (76.7%). In the Cox multivariable regression analysis, predictors of fatal ND were age, ischemic cause of heart failure, history of stroke, and longer intraoperative aortic cross-clamp time. Conclusions. Our study elucidates the characteristics and risk factors of patients who died of ND during CF-LVAD support. Further studies are required to find ways to decrease the incidence of fatal ND during CF-LVAD support. (C) 2019 by The Society of Thoracic Surgeons
引用
收藏
页码:1132 / 1138
页数:7
相关论文
共 50 条
  • [21] Outcomes for Patients With Diabetes After Continuous-Flow Left Ventricular Assist Device Implantation
    Vest, Amanda R.
    Mistak, Stanley M.
    Hachamovitch, Rory
    Mountis, Maria M.
    Moazami, Nader
    Young, James B.
    JOURNAL OF CARDIAC FAILURE, 2016, 22 (10) : 789 - 796
  • [22] Implantable Cardioverter Defibrillators and Survival in Continuous-Flow Left Ventricular Assist Device Patients
    Kutyifa, Valentina
    Fernandez, Genaro
    Sherazi, Saadia
    Aktas, Mehmet
    Huang, David
    McNitt, Scott
    Papernov, Anna
    Wang, Meng
    Massey, H. Todd
    Chen, Leway
    Alexis, Jeffrey D.
    ASAIO JOURNAL, 2019, 65 (01) : 49 - 53
  • [23] Stroke Risk Following Infection in Patients with Continuous-Flow Left Ventricular Assist Device
    Cho, Sung-Min
    Moazami, Nader
    Katz, Stuart
    Bhimraj, Adarsh
    Shrestha, Nabin K.
    Frontera, Jennifer A.
    NEUROCRITICAL CARE, 2019, 31 (01) : 72 - 80
  • [24] Stroke Risk Following Infection in Patients with Continuous-Flow Left Ventricular Assist Device
    Sung-Min Cho
    Nader Moazami
    Stuart Katz
    Adarsh Bhimraj
    Nabin K. Shrestha
    Jennifer A. Frontera
    Neurocritical Care, 2019, 31 : 72 - 80
  • [25] Anemia after continuous-flow left ventricular assist device implantation: characteristics and implications
    Amione-Guerra, Javier
    Cruz-Solbes, Ana S.
    Bhimaraj, Arvind
    Trachtenberg, Barry H.
    Pingali, Sai R.
    Estep, Jerry D.
    Park, Myung H.
    Guha, Ashrith
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2017, 40 (09) : 481 - 488
  • [26] Prognostic implications of serial outpatient blood pressure measurements in patients with an axial continuous-flow left ventricular assist device
    Pinsino, Alberto
    Castagna, Francesco
    Zuver, Amelia M.
    Royzman, Eugene A.
    Nasiri, Mojdeh
    Stohr, Eric J.
    Cagliostro, Barbara
    McDonnell, Barry
    Cockcroft, John R.
    Garan, A. Reshad
    Topkara, Veli K.
    Schulze, P. Christian
    Takeda, Koji
    Takayama, Hiroo
    Naka, Yoshifumi
    Demmer, Ryan T.
    Willey, Joshua Z.
    Yuzefpolskaya, Melana
    Colombo, Paolo C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04) : 396 - 405
  • [27] Impact of age on outcomes following continuous-flow left ventricular assist device implantation
    Lushaj, Entela B.
    Badami, Abbasali
    Osaki, Satoru
    Murray, Margaret
    Leverson, Glen
    Lozonschi, Lucian
    Akhter, Shahab
    Kohmoto, Takushi
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2015, 20 (06) : 743 - 748
  • [28] INTERMACS Analysis of Stroke During Support With Continuous-Flow Left Ventricular Assist Devices Risk Factors and Outcomes
    Acharya, Deepak
    Loyaga-Rendon, Renzo
    Morgan, Charity J.
    Sands, Kara A.
    Pamboukian, Salpy V.
    Rajapreyar, Indranee
    Holman, William L.
    Kirklin, James K.
    Tallaj, Jose A.
    JACC-HEART FAILURE, 2017, 5 (10) : 703 - 711
  • [29] Impact and Measurement of Blood Pressure During Continuous Flow Left Ventricular Assist Device Support: The Pressure Is On!
    Saeed, Omar
    Jorde, Ulrich P.
    ASAIO JOURNAL, 2019, 65 (02) : 101 - 103
  • [30] A Decade of Experience With Continuous-Flow Left Ventricular Assist Devices
    John, Ranjit
    Holley, Christopher T.
    Eckman, Peter
    Roy, Samit S.
    Cogswell, Rebecca
    Harvey, Laura
    Shumway, Sara
    Liao, Kenneth
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2016, 28 (02) : 363 - 374