Model-Based Iterative Reconstruction Technique for Ultralow-Dose Computed Tomography of the Lung A Pilot Study

被引:125
作者
Yamada, Yoshitake
Jinzaki, Masahiro [1 ]
Tanami, Yutaka
Shiomi, Eisuke [2 ]
Sugiura, Hiroaki
Abe, Takayuki [3 ]
Kuribayashi, Sachio
机构
[1] Keio Univ, Dept Diagnost Radiol, Sch Med, Shinjuku Ku, Tokyo 1608582, Japan
[2] Natl Def Med Coll Hosp, Dept Radiol, Saitama, Japan
[3] Keio Univ, Clin Res Ctr, Sch Med, Tokyo 1608582, Japan
关键词
iterative reconstruction; chest; CT; nodule; image quality; FILTERED BACK-PROJECTION; IMAGE-QUALITY; PULMONARY NODULES; CHEST CT; OBSERVER PERFORMANCE; REDUCTION;
D O I
10.1097/RLI.0b013e3182562a89
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to assess the effectiveness of a model-based iterative reconstruction (MBIR) in improving image quality and diagnostic performance of ultralow-dose computed tomography (ULDCT) of the lung. Materials and Methods: The institutional review board approved this study, and all patients provided written informed consent. Fifty-two patients underwent low-dose computed tomography (LDCT) (screening-dose, 50 mAs) and ULDCT (4 mAs) of the lung simultaneously. The LDCT images were reconstructed with filtered back projection (LDCT-FBP images) and ULDCT images were reconstructed with both MBIR (ULDCT-MBIR images) and FBP (ULDCT-FBP images). On all the 156 image series, objective image noise was measured in the thoracic aorta, and 2 blinded radiologists independently assessed subjective image quality. Another 2 blinded radiologists independently evaluated the ULDCT-MBIR and ULDCT-FBP images for the presence of noncalcified and calcified pulmonary nodules; LDCT-FBP images served as the reference. Paired t test, Wilcoxon signed rank sum test, and free-response receiver-operating characteristic analysis were used for statistical analysis of the data. Results: Compared with LDCT-FBP and ULDCT-FBP, ULDCT-MBIR had significantly reduced objective noise (both P < 0.001). Subjective noise on the ULDCT-MBIR images was comparable with that on the LDCT-FBP images but lower than that on the ULDCT-FBP images (P < 0.001). Artifacts on ULDCT-MBIR images were more numerous than those on the LDCT-FBP images (P = 0.007) but fewer than those on the ULDCT-FBP images (P < 0.001). Compared with the LDCT-FBP images, ULDCT-MBIR and ULDCT-FBP images showed reduced image sharpness (both P < 0.001). All the ULDCT-MBIR images showed a blotchy pixelated appearance; however, the performance of ULDCT-MBIR was significantly superior to that of ULDCT-FBP for the detection of noncalcified pulmonary nodules (P = 0.002). The average true-positive fractions for significantly sized noncalcified nodules (>= 4 mm) and small noncalcified nodules (<4 mm) on the ULDCT-MBIR images were 0.944 and 0.884, respectively, when LDCT-FBP images were used as reference. All of the calcified nodules were detected by both the observers on both the ULDCT-MBIR and ULDCT-FBP images. Conclusion: As compared with FBP, MBIR enables significant reduction of the image noise and artifacts and also better detection of noncalcified pulmonary nodules on ULDCT of the lung. Compared with LDCT-FBP images, ULDCT-MBIR images showed significantly reduced objective noise and comparable subjective image noise. Almost all of the noncalcified nodules and all of the calcified nodules could be detected on the ULDCT-MBIR images, when LDCT-FBP images were used as the reference.
引用
收藏
页码:482 / 489
页数:8
相关论文
共 50 条
  • [41] Evaluation of ultralow-dose computed tomography on detection of pulmonary nodules in overweight or obese adult patients
    Guo, Xiaowan
    Jia, Dezhao
    He, Lei
    Jia, Xudong
    Zhang, Danqing
    Dou, Yana
    Shen, Shanshan
    Ji, Hong
    Zhang, Shuqian
    Chen, Yingmin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (04):
  • [42] Detection of Incidental Nonosseous Thoracic Pathology on State-of-the-Art Ultralow-Dose Protocol Computed Tomography in Pediatric Patients With Pectus Excavatum
    Gallo-Bernal, Sebastian
    Kim, Jesi
    Savage, Cristy
    Nimkin, Katherine
    Gee, Michael S.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (03) : 492 - 498
  • [43] Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations
    Neroladaki, Angeliki
    Botsikas, Diomidis
    Boudabbous, Sana
    Becker, Christoph D.
    Montet, Xavier
    EUROPEAN RADIOLOGY, 2013, 23 (02) : 360 - 366
  • [44] The Impact of Iterative Reconstruction in Low-Dose Computed Tomography on the Evaluation of Diffuse Interstitial Lung Disease
    Lim, Hyun-Ju
    Chung, Myung Jin
    Shin, Kyung Eun
    Hwang, Hye Sun
    Lee, Kyung Soo
    KOREAN JOURNAL OF RADIOLOGY, 2016, 17 (06) : 950 - 960
  • [45] EVALUATION OF MODEL-BASED ITERATIVE RECONSTRUCTION IN ABDOMINAL COMPUTED TOMOGRAPHY IMAGING AT TWO DIFFERENT DOSE LEVELS
    Hettinger, E.
    Aurumskjold, M-L
    Sartor, H.
    Holmquist, F.
    Svard, D.
    Timberg, P.
    RADIATION PROTECTION DOSIMETRY, 2021, 195 (3-4) : 205 - 211
  • [46] Knowledge-based iterative model reconstruction: comparative image quality and radiation dose with a pediatric computed tomography phantom
    Ryu, Young Jin
    Choi, Young Hun
    Cheon, Jung-Eun
    Ha, Seongmin
    Kim, Woo Sun
    Kim, In-One
    PEDIATRIC RADIOLOGY, 2016, 46 (03) : 303 - 315
  • [47] High-resolution CT with new model-based iterative reconstruction with resolution preference algorithm in evaluations of lung nodules: Comparison with conventional model-based iterative reconstruction and adaptive statistical iterative reconstruction
    Yasaka, Koichiro
    Katsura, Masaki
    Hanaoka, Shouhei
    Sato, Jiro
    Ohtomo, Kuni
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (03) : 599 - 606
  • [48] Image quality comparison between model-based iterative reconstruction and adaptive statistical iterative reconstruction chest computed tomography in cystic fibrosis patients
    Lin, Sandra
    Lin, Monica
    Lau, Kenneth K.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2019, 63 (05) : 602 - 609
  • [49] Ultra-Low-Dose Fetal CT With Model-Based Iterative Reconstruction: A Prospective Pilot Study
    Imai, Rumi
    Miyazaki, Osamu
    Horiuchi, Tetsuya
    Asano, Keisuke
    Nishimura, Gen
    Sago, Haruhiko
    Nosaka, Shunsuke
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (06) : 1358 - 1365
  • [50] A feasibility study of pulmonary nodule detection by ultralow-dose CT with adaptive statistical iterative reconstruction-V technique
    Ye, Kai
    Zhu, Qiao
    Li, Meijiao
    Lu, Yuliu
    Yuan, Huishu
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 119