Model-Based Iterative Reconstruction Technique for Ultralow-Dose Computed Tomography of the Lung A Pilot Study

被引:126
作者
Yamada, Yoshitake
Jinzaki, Masahiro [1 ]
Tanami, Yutaka
Shiomi, Eisuke [2 ]
Sugiura, Hiroaki
Abe, Takayuki [3 ]
Kuribayashi, Sachio
机构
[1] Keio Univ, Dept Diagnost Radiol, Sch Med, Shinjuku Ku, Tokyo 1608582, Japan
[2] Natl Def Med Coll Hosp, Dept Radiol, Saitama, Japan
[3] Keio Univ, Clin Res Ctr, Sch Med, Tokyo 1608582, Japan
关键词
iterative reconstruction; chest; CT; nodule; image quality; FILTERED BACK-PROJECTION; IMAGE-QUALITY; PULMONARY NODULES; CHEST CT; OBSERVER PERFORMANCE; REDUCTION;
D O I
10.1097/RLI.0b013e3182562a89
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to assess the effectiveness of a model-based iterative reconstruction (MBIR) in improving image quality and diagnostic performance of ultralow-dose computed tomography (ULDCT) of the lung. Materials and Methods: The institutional review board approved this study, and all patients provided written informed consent. Fifty-two patients underwent low-dose computed tomography (LDCT) (screening-dose, 50 mAs) and ULDCT (4 mAs) of the lung simultaneously. The LDCT images were reconstructed with filtered back projection (LDCT-FBP images) and ULDCT images were reconstructed with both MBIR (ULDCT-MBIR images) and FBP (ULDCT-FBP images). On all the 156 image series, objective image noise was measured in the thoracic aorta, and 2 blinded radiologists independently assessed subjective image quality. Another 2 blinded radiologists independently evaluated the ULDCT-MBIR and ULDCT-FBP images for the presence of noncalcified and calcified pulmonary nodules; LDCT-FBP images served as the reference. Paired t test, Wilcoxon signed rank sum test, and free-response receiver-operating characteristic analysis were used for statistical analysis of the data. Results: Compared with LDCT-FBP and ULDCT-FBP, ULDCT-MBIR had significantly reduced objective noise (both P < 0.001). Subjective noise on the ULDCT-MBIR images was comparable with that on the LDCT-FBP images but lower than that on the ULDCT-FBP images (P < 0.001). Artifacts on ULDCT-MBIR images were more numerous than those on the LDCT-FBP images (P = 0.007) but fewer than those on the ULDCT-FBP images (P < 0.001). Compared with the LDCT-FBP images, ULDCT-MBIR and ULDCT-FBP images showed reduced image sharpness (both P < 0.001). All the ULDCT-MBIR images showed a blotchy pixelated appearance; however, the performance of ULDCT-MBIR was significantly superior to that of ULDCT-FBP for the detection of noncalcified pulmonary nodules (P = 0.002). The average true-positive fractions for significantly sized noncalcified nodules (>= 4 mm) and small noncalcified nodules (<4 mm) on the ULDCT-MBIR images were 0.944 and 0.884, respectively, when LDCT-FBP images were used as reference. All of the calcified nodules were detected by both the observers on both the ULDCT-MBIR and ULDCT-FBP images. Conclusion: As compared with FBP, MBIR enables significant reduction of the image noise and artifacts and also better detection of noncalcified pulmonary nodules on ULDCT of the lung. Compared with LDCT-FBP images, ULDCT-MBIR images showed significantly reduced objective noise and comparable subjective image noise. Almost all of the noncalcified nodules and all of the calcified nodules could be detected on the ULDCT-MBIR images, when LDCT-FBP images were used as the reference.
引用
收藏
页码:482 / 489
页数:8
相关论文
共 42 条
[1]  
AAPM, 2008, MEASUREMENT REPORTIN
[2]   Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening [J].
Aberle, Denise R. ;
Adams, Amanda M. ;
Berg, Christine D. ;
Black, William C. ;
Clapp, Jonathan D. ;
Fagerstrom, Richard M. ;
Gareen, Ilana F. ;
Gatsonis, Constantine ;
Marcus, Pamela M. ;
Sicks, JoRean D. .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (05) :395-409
[3]  
[Anonymous], PHYS MED IN PRESS
[4]   UK Lung Screen (UKLS) nodule management protocol: modelling of a single screen randomised controlled trial of low-dose CT screening for lung cancer [J].
Baldwin, D. R. ;
Duffy, S. W. ;
Wald, N. J. ;
Page, R. ;
Hansell, D. M. ;
Field, J. K. .
THORAX, 2011, 66 (04) :308-313
[5]   Computed Tomography of the Lung in the High-Pitch Mode Is Breath Holding Still Required? [J].
Baumueller, Stephan ;
Alkadhi, Hatem ;
Stolzmann, Paul ;
Frauenfelder, Thomas ;
Goetti, Robert ;
Schertler, Thomas ;
Plass, Andre ;
Falk, Volkmar ;
Feuchtner, Gudrun ;
Scheffel, Hans ;
Desbiolles, Lotus ;
Leschka, Sebastian .
INVESTIGATIVE RADIOLOGY, 2011, 46 (04) :240-245
[6]   A generalized Gaussian image model for edge-preserving MAP estimation [J].
Bournan, Charles ;
Sauer, Ken .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1993, 2 (03) :296-310
[7]   Analysis of location specific observer performance data: Validated extensions of the jackknife free-response (JAFROC) method [J].
Chakraborty, Dev P. .
ACADEMIC RADIOLOGY, 2006, 13 (10) :1187-1193
[8]   Observer studies involving detection and localization: Modeling, analysis, and validation [J].
Chakraborty, DP ;
Berbaum, KS .
MEDICAL PHYSICS, 2004, 31 (08) :2313-2330
[9]   Distance-driven projection and backprojection in three dimensions [J].
De Man, B ;
Basu, S .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11) :2463-2475
[10]  
Diederich S, 2000, CANCER, V89, P2457, DOI 10.1002/1097-0142(20001201)89:11+<2457::AID-CNCR22>3.0.CO