Three-Dimensional Paper-Based Microfluidic Analysis Device for Simultaneous Detection of Multiple Biomarkers with a Smartphone

被引:37
作者
Baek, Seung Ho [1 ]
Park, Chanyong [2 ]
Jeon, Jaehyung [1 ]
Park, Sungsu [1 ,2 ,3 ]
机构
[1] Sungkyunkwan Univ, Sch Mech Engn, Suwon 16419, South Korea
[2] Sungkyunkwan Univ, Dept Biomed Engn, Suwon 16419, South Korea
[3] Sungkyunkwan Univ, Biomed Inst Convergence SKKU BICS, Suwon 16419, South Korea
来源
BIOSENSORS-BASEL | 2020年 / 10卷 / 11期
基金
新加坡国家研究基金会;
关键词
paper-based microfluidic device; colorimetric; multiple detection; smartphone application; ALKALINE-PHOSPHATASE; GLUCOSE; INTENSITY; DISEASE; ASSAY;
D O I
10.3390/bios10110187
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Paper-based microfluidic analysis devices (mu PADs) have attracted attention as a cost-effective platform for point-of-care testing (POCT), food safety, and environmental monitoring. Recently, three-dimensional (3D)-mu PADs have been developed to improve the performance of mu PADs. For accurate diagnosis of diseases, however, 3D-mu PADs need to be developed to simultaneously detect multiple biomarkers. Here, we report a 3D-mu PADs platform for the detection of multiple biomarkers that can be analyzed and diagnosed with a smartphone. The 3D-mu PADs were fabricated using a 3D digital light processing printer and consisted of a sample reservoir (300 mu L) connected to 24 detection zones (of 4 mm in diameter) through eight microchannels (of 2 mm in width). With the smartphone application, eight different biomarkers related to various diseases were detectable in concentrations ranging from normal to abnormal conditions: glucose (0-20 mmol/L), cholesterol (0-10 mmol/L), albumin (0-7 g/dL), alkaline phosphatase (0-800 U/L), creatinine (0-500 mu mol/L), aspartate aminotransferase (0-800 U/L), alanine aminotransferase (0-1000 U/L), and urea nitrogen (0-7.2 mmol/L). These results suggest that 3D-mu PADs can be used as a POCT platform for simultaneous detection of multiple biomarkers.
引用
收藏
页数:12
相关论文
共 50 条
[41]   Strategies for the detection of target analytes using microfluidic paper-based analytical devices [J].
Zheng, Wei ;
Wang, Kan ;
Xu, Hao ;
Zheng, Chujun ;
Cao, Bo ;
Qin, Qi ;
Jin, Qinghui ;
Cui, Daxiang .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (09) :2429-2445
[42]   Point-of-need determination of blood typing using a three-dimensional origami microfluidic paper based analytical device [J].
Ardakani, Farshad ;
Shojaeifard, Zahra ;
Hemmateenejad, Bahram .
MICROCHEMICAL JOURNAL, 2022, 181
[43]   A Review on Microfluidic Paper-Based Analytical Devices for Glucose Detection [J].
Liu, Shuopeng ;
Su, Wenqiong ;
Ding, Xianting .
SENSORS, 2016, 16 (12) :1-17
[44]   Microfluidic Paper-Based Analytical Devices for Colorimetric Detection of Lactoferrin [J].
Kudo, Hiroko ;
Maejima, Kento ;
Hiruta, Yuki ;
Citterio, Daniel .
SLAS TECHNOLOGY, 2020, 25 (01) :47-57
[45]   A Low-Cost and High Sensitive Paper-Based Microfluidic Device for Rapid Detection of Glucose in Fruit [J].
Li, Zexian ;
Zhu, Yongheng ;
Zhang, Weijia ;
Xu, Changhua ;
Pan, Yingjie ;
Zhao, Yong .
FOOD ANALYTICAL METHODS, 2017, 10 (03) :666-674
[46]   Inkjet printed microfluidic paper-based analytical device (μPAD) for glucose colorimetric detection in artificial urine [J].
Han Zhang ;
Ethan Smith ;
Wei Zhang ;
Anhong Zhou .
Biomedical Microdevices, 2019, 21
[47]   Inkjet printed microfluidic paper-based analytical device (PAD) for glucose colorimetric detection in artificial urine [J].
Zhang, Han ;
Smith, Ethan ;
Zhang, Wei ;
Zhou, Anhong .
BIOMEDICAL MICRODEVICES, 2019, 21 (03)
[48]   A Low-Cost and High Sensitive Paper-Based Microfluidic Device for Rapid Detection of Glucose in Fruit [J].
Zexian Li ;
Yongheng Zhu ;
Weijia Zhang ;
Changhua Xu ;
Yingjie Pan ;
Yong Zhao .
Food Analytical Methods, 2017, 10 :666-674
[49]   Paper-based multiplex analytical device for simultaneous detection of Clostridioides difficile toxins and glutamate dehydrogenase [J].
Han, Do Kyoung ;
Oh, Jeonghyun ;
Lee, Jaehyeon ;
Cho, Yong Gon ;
Park, Ju Seong ;
Choi, Jong Soon ;
Kim, Dal Sik ;
Kwon, Joseph .
BIOSENSORS & BIOELECTRONICS, 2021, 176
[50]   Digital colorimetric analysis for estimation of iron in water with smartphone-assisted microfluidic paper-based analytical devices [J].
Balasubramanian, Sivasamy ;
Udayabhanu, Aditya ;
Kumar, Ponnusamy Senthil ;
Muthamilselvi, Ponnuchamy ;
Eswari, Chidhambaram ;
Vasantavada, Aalekhya ;
Kanetkar, Shreyas ;
Kapoor, Ashish .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2023, 103 (11) :2480-2497