Application of analyzer based X-ray imaging technique for detection of ultrasound induced cavitation bubbles from a physical therapy unit

被引:8
作者
Izadifar, Zahra [1 ]
Belev, George [2 ]
Babyn, Paul [3 ,4 ]
Chapman, Dean [1 ,5 ]
机构
[1] Univ Saskatchewan, Div Biomed Engn, Coll Engn, Saskatoon, SK S7N 5A9, Canada
[2] Univ Saskatchewan, Canadian Light Source Inc, Biomed Imaging & Therapy Beamlines, Saskatoon, SK S7N 2V3, Canada
[3] Univ Saskatchewan, Dept Med Imaging, Royal Univ Hosp, Saskatoon, SK S7N 0W8, Canada
[4] Saskatoon Hlth Reg, Saskatoon, SK S7N 0W8, Canada
[5] Univ Saskatchewan, Anat & Cell Biol, Saskatoon, SK S7N 5E5, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
Synchrotron; X-ray imaging; Analyzer based imaging; Detection; Ultrasound; Cavitation bubble; Therapeutic ultrasound; INDUCED LUNG HEMORRHAGE; SHOCK-WAVE LITHOTRIPSY; INTENSITY FOCUSED ULTRASOUND; IN-VIVO; SUPERTHRESHOLD BEHAVIOR; ACOUSTIC CAVITATION; PULSED ULTRASOUND; DAMAGE; EXPOSURE; RABBIT;
D O I
10.1186/s12938-015-0085-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The observation of ultrasound generated cavitation bubbles deep in tissue is very difficult. The development of an imaging method capable of investigating cavitation bubbles in tissue would improve the efficiency and application of ultrasound in the clinic. Among the previous imaging modalities capable of detecting cavitation bubbles in vivo, the acoustic detection technique has the positive aspect of in vivo application. However the size of the initial cavitation bubble and the amplitude of the ultrasound that produced the cavitation bubbles, affect the timing and amplitude of the cavitation bubbles' emissions. Methods: The spatial distribution of cavitation bubbles, driven by 0.8835 MHz therapeutic ultrasound system at output power of 14 Watt, was studied in water using a synchrotron X-ray imaging technique, Analyzer Based Imaging (ABI). The cavitation bubble distribution was investigated by repeated application of the ultrasound and imaging the water tank. The spatial frequency of the cavitation bubble pattern was evaluated by Fourier analysis. Acoustic cavitation was imaged at four different locations through the acoustic beam in water at a fixed power level. The pattern of cavitation bubbles in water was detected by synchrotron X-ray ABI. Results: The spatial distribution of cavitation bubbles driven by the therapeutic ultrasound system was observed using ABI X-ray imaging technique. It was observed that the cavitation bubbles appeared in a periodic pattern. The calculated distance between intervals revealed that the distance of frequent cavitation lines (intervals) is one-half of the acoustic wave length consistent with standing waves. Conclusion: This set of experiments demonstrates the utility of synchrotron ABI for visualizing cavitation bubbles formed in water by clinical ultrasound systems working at high frequency and output powers as low as a therapeutic system.
引用
收藏
页数:12
相关论文
共 37 条
[1]   Diffraction enhanced x-ray imaging [J].
Chapman, D ;
Thomlinson, W ;
Johnston, RE ;
Washburn, D ;
Pisano, E ;
Gmur, N ;
Zhong, Z ;
Menk, R ;
Arfelli, F ;
Sayers, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2015-2025
[2]   Comparison of conventional and ultrasound-assisted extraction of carvone and limonene from caraway seeds [J].
Chemat, S ;
Lagha, A ;
AitAmar, H ;
Bartels, PV ;
Chemat, F .
FLAVOUR AND FRAGRANCE JOURNAL, 2004, 19 (03) :188-195
[3]   LUNG DAMAGE FROM EXPOSURE TO PULSED ULTRASOUND [J].
CHILD, SZ ;
HARTMAN, CL ;
SCHERY, LA ;
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (08) :817-825
[4]  
Cleveland R.O., 2007, SMITHS TXB ENDOUROLO, V1, P529, DOI DOI 10.1002/9781444345148.CH49
[5]   Role of acoustic cavitation in the delivery and monitoring of cancer treatment by high-intensity focused ultrasound (HIFU) [J].
Coussios, C. C. ;
Farny, C. H. ;
Ter Haar, G. ;
Roy, R. A. .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2007, 23 (02) :105-120
[6]   DAMAGE TO RED-BLOOD-CELLS INDUCED BY ACOUSTIC CAVITATION [J].
DANIELS, S ;
KODAMA, T ;
PRICE, DJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (01) :105-111
[7]  
Delius M., 1990, J LITHOTRIPSY STONE, V2, P103
[8]  
Duck F.A., 1998, ULTRASOUND MED
[9]   Kidney damage and renal functional changes are minimized by waveform control that suppresses cavitation in shock wave lithotripsy [J].
Evan, AP ;
Willis, LR ;
McAteer, JA ;
Bailey, MR ;
Connors, BA ;
Shao, YZ ;
Lingeman, JE ;
Williams, JC ;
Fineberg, NS ;
Crum, LA .
JOURNAL OF UROLOGY, 2002, 168 (04) :1556-1562
[10]   Ultrasonic cavitation monitoring by acoustic noise power measurement [J].
Frohly, J ;
Labouret, S ;
Bruneel, C ;
Looten-Baquet, I ;
Torguet, R .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2000, 108 (05) :2012-2020