Strategies to avoid electrode fouling for nimesulide detection using unmodified electrodes

被引:14
作者
da Silva, Iranaldo Santos [1 ,2 ]
Capovilla, Bruno [1 ]
Garcia Freitas, Kellen Heloizy [3 ]
Angnes, Lucio [1 ]
机构
[1] Univ Sao Paulo, Inst Quim, Dept Quim Fundamental, BR-05508000 Sao Paulo, Brazil
[2] Co Saneamento Ambiental Maranhao, BR-65020906 Sao Luis, MA, Brazil
[3] Fed Univ Para, Fac Quim, BR-06850508 Maraba, PA, Brazil
基金
巴西圣保罗研究基金会;
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; GLASSY-CARBON ELECTRODE; VOLTAMMETRIC DETERMINATION; HUMAN PLASMA; PHARMACEUTICALS; HPLC; HYDROXYNIMESULIDE; BIOAVAILABILITY; VALIDATION; OXIDATION;
D O I
10.1039/c3ay40463c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Voltammetric quantification of nimesulide presents a serious drawback due to surface fouling on unmodified electrodes. In the anodic region, the electrode fouling effects are critical and alternative procedures are required to bypass this effect. In the present study, new strategies for nimesulide quantification in pharmaceutical agents in the anodic region were developed. We propose a simple procedure to overcome this problem: just doing an electrochemical conditioning process before measurement. This was achieved by differential pulse voltammetry (DPV) and multiple pulsed amperometry (MPA), using batch and in flow injection analyses, respectively. These studies were performed in the presence of 0.1 mol L-1 H2SO4 and the application of 1.6 V to the electrode surface at short time intervals was effective both for electrode surface cleaning and for attaining a steady state regime. The new procedures proposed here allow for quantification of nimesulide in both anodic and cathodic regions, favouring the quantification of this species in complex samples. The results obtained here were in good agreement with the official spectrophotometric method recommended in the Brazilian Pharmacopoeia.
引用
收藏
页码:3546 / 3551
页数:6
相关论文
共 32 条
[1]  
Alvarez-Lueje A, 1998, ANAL LETT, V31, P1173
[2]   Voltammetric study of nimesulide and its differential pulse polarographic determination in pharmaceuticals [J].
AlvarezLueje, A ;
Vasquez, P ;
NunezVergara, LJ ;
Squella, JA .
ELECTROANALYSIS, 1997, 9 (15) :1209-1213
[3]   A THEORETICAL BASIS FOR A BIOPHARMACEUTIC DRUG CLASSIFICATION - THE CORRELATION OF IN-VITRO DRUG PRODUCT DISSOLUTION AND IN-VIVO BIOAVAILABILITY [J].
AMIDON, GL ;
LENNERNAS, H ;
SHAH, VP ;
CRISON, JR .
PHARMACEUTICAL RESEARCH, 1995, 12 (03) :413-420
[4]  
Biscarini L, 1988, DRUG TODAY, V70, P23
[5]  
Brett A.M.O., 1993, Electroquimica: principios, metodos e aplicacoes
[6]  
Rolim CMB, 2007, ARZNEIMITTELFORSCH, V57, P537
[7]   A simple method for determination of nimesulide in rat blood samples by high-performance liquid chromatography [J].
Carrasco-Portugal, MC ;
Granados-Soto, V ;
Camacho-Vieyra, GA ;
Párez-Urizar, J ;
Flores-Murrieta, FJ .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (14) :2237-2244
[8]   Flow amperometric determination of pharmaceuticals with on-line electrode surface renewal [J].
Catarino, RIL ;
Conceiçao, ACL ;
Garcia, MBQ ;
Gonçalves, MLS ;
Lima, JLFC ;
dos Santos, MMC .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (04) :571-580
[9]   Quantification of N-acetylcysteine in pharmaceuticals using cobalt phthalocyanine modified graphite electrodes [J].
da Silva, Iranaldo Santos ;
Antao Araujo, Marcelo Fernando ;
Ferreira, Henrique Augusto ;
Gomes Varela, Jaldyr de Jesus, Jr. ;
Carvalho Neiva Tanaka, Sonia Maria ;
Tanaka, Auro Atsushi ;
Angnes, Lucio .
TALANTA, 2011, 83 (05) :1701-1706
[10]  
El-Sayed GO, 2009, LAT AM J PHARM, V28, P741