Development and validation of a hydrophilic interaction liquid chromatography-tandem mass spectrometry method for the simultaneous determination of five first-line antituberculosis drugs in plasma

被引:43
作者
Zhou, Zhifeng [1 ]
Wu, Xianbo [2 ]
Wei, Qinzhi [3 ]
Liu, Yungang [3 ]
Liu, Peng [4 ]
Ma, Ande [1 ]
Zou, Fei [5 ]
机构
[1] Southern Med Univ, Sch Publ Hlth & Trop Med, Dept Hlth Inspect & Quarantine, Guangzhou 510515, Guangdong, Peoples R China
[2] Southern Med Univ, Sch Publ Hlth & Trop Med, Dept Epidemiol, Guangzhou 510515, Guangdong, Peoples R China
[3] Southern Med Univ, Sch Publ Hlth & Trop Med, Dept Toxicol, Guangzhou 510515, Guangdong, Peoples R China
[4] Southern Med Univ, Nan Fang Hosp, Dept Orthoped & Spinal Surg, Guangzhou 510515, Guangdong, Peoples R China
[5] Southern Med Univ, Sch Publ Hlth & Trop Med, Dept Occupat Hlth & Occupat Med, Guangzhou 510515, Guangdong, Peoples R China
关键词
Antituberculosis drug; Therapeutic drug monitoring; Hydrophilic interaction liquid chromatography; Tandem mass spectrometry; PULMONARY TUBERCULOSIS; PHARMACEUTICAL-PREPARATIONS; ANTIMYCOBACTERIAL DRUGS; SERUM CONCENTRATIONS; RIFAMPICIN; PYRAZINAMIDE; ETHAMBUTOL; BLOOD; STREPTOMYCIN; HPLC;
D O I
10.1007/s00216-013-7049-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new, sensitive and fast method for the simultaneous determination of pyrazinamide, isoniazid, streptomycin, ethambutol, and rifampicin in human plasma was developed and validated. The method required only 100 mu L of plasma and one step for sample preparation by protein precipitation. The drugs were separated by using a hydrophilic interaction liquid chromatography (HILIC) column. The mobile phase was methanol and water (0.1 % formic acid and 5 mM ammonium acetate, pH 3.0 +/- 0.1) in a ratio of 65:35 (v/v), which was eluted at an isocratic flow rate of 0.5 mL/min. Tandem mass spectrometry was performed with a triple-quadrupole tandem mass spectrometer. By use of the HILIC column, the detection was free of ion-pair reagents in the mobile phase, with no significant matrix effects. The total run time was less than 2 min for each sample. The method was validated by evaluating its selectivity, sensitivity, linearity, accuracy, and precision according to US Food and Drug Administration guidelines. The lower limit of quantification was 4.0 ng/mL for pyrazinamide, isoniazid, and rifampicin, 0.5 ng/mL for ethambutol, and 10.0 ng/mL for streptomycin. The intraday precision and interday precision were less than 9 %, with the accuracy ranging between -9.3 and 7.3 %. The method was successfully applied to therapeutic drug monitoring of 33 patients with tuberculosis after administration of standard antituberculosis drugs. The method has been proved to meet the high-throughput requirements in therapeutic drug monitoring.
引用
收藏
页码:6323 / 6335
页数:13
相关论文
共 40 条
  • [21] Liquid chromatographic determination of isoniazid, pyrazinamide and rifampicin from pharmaceutical preparations and blood
    Khuhawar, MY
    Rind, FMA
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 766 (02): : 357 - 363
  • [22] Low serum antimycobacterial drug levels in non-HIV-infected tuberculosis patients
    Kimerling, ME
    Phillips, P
    Patterson, P
    Hall, M
    Robinson, CA
    Dunlap, NE
    [J]. CHEST, 1998, 113 (05) : 1178 - 1183
  • [23] Therapeutic drug monitoring in the treatment of tuberculosis patients
    Magis-Escurra, Cecile
    van den Boogaard, Jossy
    IJdema, Dirk
    Boeree, Martin
    Aarnoutse, Rob
    [J]. PULMONARY PHARMACOLOGY & THERAPEUTICS, 2012, 25 (01) : 83 - 86
  • [24] The effect of hemodialysis on isoniazid, rifampin, pyrazinamide, and ethambutol
    Malone, RS
    Fish, DN
    Spiegel, DM
    Childs, JM
    Peloquin, CA
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (05) : 1580 - 1584
  • [25] Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS
    Matuszewski, BK
    Constanzer, ML
    Chavez-Eng, CM
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (13) : 3019 - 3030
  • [26] Minikis RM, 2003, LC GC N AM, V21, P1050
  • [27] Therapeutic isoniazid monitoring using a simple high-performance liquid chromatographic method with ultraviolet detection
    Moussa, LA
    Khassouani, CE
    Soulaymani, R
    Jana, M
    Cassanas, G
    Alric, R
    Hüe, B
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 766 (01): : 181 - 187
  • [28] The advantages of ESI-MS detection in conjunction with HILIC mode separations: Fundamentals and applications
    Nguyen, Hien P.
    Schug, Kevin A.
    [J]. JOURNAL OF SEPARATION SCIENCE, 2008, 31 (09) : 1465 - 1480
  • [29] Determination of Antituberculosis Drug Concentration in Human Plasma by MALDI-TOF/TOF
    Notari, Stefania
    Mancone, Carmine
    Sergi, Manuel
    Gullotta, Francesca
    Bevilacqua, Nazzario
    Tempestilli, Massimo
    Urso, Rocco
    Lauria, Francesco Nicola
    Pucillo, Leopoldo Paolo
    Tripodi, Marco
    Ascenzi, Paolo
    [J]. IUBMB LIFE, 2010, 62 (05) : 387 - 393
  • [30] Therapeutic drug monitoring in the treatment of tuberculosis
    Peloquin, CA
    [J]. DRUGS, 2002, 62 (15) : 2169 - 2183