Development and validation of a hydrophilic interaction liquid chromatography-tandem mass spectrometry method for the simultaneous determination of five first-line antituberculosis drugs in plasma

被引:43
作者
Zhou, Zhifeng [1 ]
Wu, Xianbo [2 ]
Wei, Qinzhi [3 ]
Liu, Yungang [3 ]
Liu, Peng [4 ]
Ma, Ande [1 ]
Zou, Fei [5 ]
机构
[1] Southern Med Univ, Sch Publ Hlth & Trop Med, Dept Hlth Inspect & Quarantine, Guangzhou 510515, Guangdong, Peoples R China
[2] Southern Med Univ, Sch Publ Hlth & Trop Med, Dept Epidemiol, Guangzhou 510515, Guangdong, Peoples R China
[3] Southern Med Univ, Sch Publ Hlth & Trop Med, Dept Toxicol, Guangzhou 510515, Guangdong, Peoples R China
[4] Southern Med Univ, Nan Fang Hosp, Dept Orthoped & Spinal Surg, Guangzhou 510515, Guangdong, Peoples R China
[5] Southern Med Univ, Sch Publ Hlth & Trop Med, Dept Occupat Hlth & Occupat Med, Guangzhou 510515, Guangdong, Peoples R China
关键词
Antituberculosis drug; Therapeutic drug monitoring; Hydrophilic interaction liquid chromatography; Tandem mass spectrometry; PULMONARY TUBERCULOSIS; PHARMACEUTICAL-PREPARATIONS; ANTIMYCOBACTERIAL DRUGS; SERUM CONCENTRATIONS; RIFAMPICIN; PYRAZINAMIDE; ETHAMBUTOL; BLOOD; STREPTOMYCIN; HPLC;
D O I
10.1007/s00216-013-7049-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new, sensitive and fast method for the simultaneous determination of pyrazinamide, isoniazid, streptomycin, ethambutol, and rifampicin in human plasma was developed and validated. The method required only 100 mu L of plasma and one step for sample preparation by protein precipitation. The drugs were separated by using a hydrophilic interaction liquid chromatography (HILIC) column. The mobile phase was methanol and water (0.1 % formic acid and 5 mM ammonium acetate, pH 3.0 +/- 0.1) in a ratio of 65:35 (v/v), which was eluted at an isocratic flow rate of 0.5 mL/min. Tandem mass spectrometry was performed with a triple-quadrupole tandem mass spectrometer. By use of the HILIC column, the detection was free of ion-pair reagents in the mobile phase, with no significant matrix effects. The total run time was less than 2 min for each sample. The method was validated by evaluating its selectivity, sensitivity, linearity, accuracy, and precision according to US Food and Drug Administration guidelines. The lower limit of quantification was 4.0 ng/mL for pyrazinamide, isoniazid, and rifampicin, 0.5 ng/mL for ethambutol, and 10.0 ng/mL for streptomycin. The intraday precision and interday precision were less than 9 %, with the accuracy ranging between -9.3 and 7.3 %. The method was successfully applied to therapeutic drug monitoring of 33 patients with tuberculosis after administration of standard antituberculosis drugs. The method has been proved to meet the high-throughput requirements in therapeutic drug monitoring.
引用
收藏
页码:6323 / 6335
页数:13
相关论文
共 40 条
  • [1] Determination of rifampicin in human plasma and blood spots by high performance liquid chromatography with UV detection: A potential method for therapeutic drug monitoring
    Allanson, A. L.
    Cotton, M. M.
    Tettey, J. N. A.
    Boyter, A. C.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (04) : 963 - 969
  • [2] [Anonymous], 2010, TD2010IDCR WADA
  • [3] [Anonymous], 2001, Guidance for industry, bioanalytical method validation
  • [4] Determination of ethambutol in human plasma and urine by high-performance liquid chromatography with fluorescence detection
    Breda, M
    Marrari, P
    Pianezzola, E
    Benedetti, MS
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1996, 729 (1-2) : 301 - 307
  • [5] A liquid chromatography/tandem mass spectrometry method for the simultaneous quantification of isoniazid and ethambutol in human plasma
    Chen, XY
    Song, B
    Jiang, HJ
    Yu, K
    Zhong, DF
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (18) : 2591 - 2596
  • [6] European Medicines Agency, 2011, EMEACHMPEWP192217200
  • [7] Isoniazid Blood Levels in Patients with Pulmonary Tuberculosis at a Tuberculosis Referral Center
    Fahimi, Fanak
    Kobarfard, Farzad
    Tabarsi, Payam
    Hemmati, Shabnam
    Salamzadeh, Jamshid
    Baniasadi, Shadi
    [J]. CHEMOTHERAPY, 2011, 57 (01) : 7 - 11
  • [8] Simultaneous determination of isoniazid, rifampicin, levofloxacin in mouse tissues and plasma by high performance liquid chromatography-tandem mass spectrometry
    Fang, Ping-Fei
    Cai, Hua-Lin
    Li, Huan-De
    Zhu, Rong-Hua
    Tan, Qin-You
    Gao, Wei
    Xu, Ping
    Liu, Yi-Ping
    Zhang, Wen-Yuan
    Chen, Yong-Chang
    Zhang, Feng
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (24): : 2286 - 2291
  • [9] Effect of the mobile phase composition on the separation and detection of intact proteins by reversed-phase liquid chromatography -: electro spray mass spectrometry
    García, MC
    Hogenboom, AC
    Zappey, H
    Irth, H
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 957 (02) : 187 - 199
  • [10] A rapid and robust liquid chromatography/tandem mass spectrometry method for simultaneous analysis of anti-tuberculosis drugs-Ethambutol and pyrazinamide in human plasma
    Gong, Zhilong
    Basir, Yousef
    Chu, David
    McCort-Tipton, Melanie
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (16-17): : 1698 - 1704