A trabecular metal tibial component in total knee replacement in patients younger than 60 years A TWO-YEAR RADIOSTEREOPHOTOGRAMMETRIC ANALYSIS

被引:55
作者
Henricson, A. [2 ]
Linder, L. [3 ]
Nilsson, K. G. [1 ]
机构
[1] Umea Univ Hosp, Dept Orthopaed, S-90185 Umea, Sweden
[2] Falu Gen Hosp, Dept Orthopaed, S-79182 Falun, Sweden
[3] Hassleholm Hosp, Dept Orthopaed, S-28125 Hassleholm, Sweden
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2008年 / 90B卷 / 12期
关键词
D O I
10.1302/0301-620X.90B12.20797
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We compared the performance of uncemented trabecular metal tibial components in total knee replacement with that of cemented tibial components in patients younger than 60 years over two years using radiostereophotogrammetric analysis (RSA). A total of 22 consecutive patients (mean age 53 years, 33 to 59, 26 knees) received an uncemented NexGen trabecular metal cruciate-retaining monobloc tibial component and 19 (mean 53 years, 44 to 59, 21 knees) a cemented NexGen Option cruciate-retaining modular tibial component. All the trabecular metal components migrated during the initial three months and then stabilised. The exception was external rotation, which did not stabilise until 12 months. Unlike conventional metal-backed implants which displayed a tilting migration comprising subsidence and lift-off from the tibial tray, most of the trabecular metal components showed subsidence only, probably due to the elasticity of the implant. This pattern of subsidence is regarded as being beneficial for uncemented fixation.
引用
收藏
页码:1585 / 1593
页数:9
相关论文
共 46 条
[1]   Low-conforming all-polyethylene tibial component not inferior to metal-backed component in cemented total knee arthroplasty -: Prospective, randomized radiostereometric analysis study of the AGC total knee prosthesis [J].
Adalberth, G ;
Nilsson, KG ;
Byström, S ;
Kolstad, K ;
Milbrink, J .
JOURNAL OF ARTHROPLASTY, 2000, 15 (06) :783-792
[2]   All-polyethylene versus metal-backed and stemmed tibial components in cemented total knee arthroplasty -: A prospective, randomised RSA study [J].
Adalberth, G ;
Nilsson, KG ;
Byström, S ;
Kolstad, K ;
Milbrink, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (06) :825-831
[3]   THE EFFECT OF A STEM ON THE TIBIAL COMPONENT OF KNEE ARTHROPLASTY - A ROENTGEN STEREOPHOTOGRAMMETRIC STUDY OF UNCEMENTED TIBIAL COMPONENTS IN THE FREEMAN-SAMUELSON KNEE ARTHROPLASTY [J].
ALBREKTSSON, BEJ ;
RYD, L ;
CARLSSON, LV ;
FREEMAN, MAR ;
HERBERTS, P ;
REGNER, L ;
SELVIK, G .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (02) :252-258
[4]  
Bellemans J, 1999, ACTA ORTHOP SCAND, V70, P1
[5]   In vivo determination of posterior femoral rollback for subjects having a NexGen posterior cruciate-retaining total knee arthroplasty [J].
Bertin, KC ;
Komistek, RD ;
Dennis, DA ;
Hoff, WA ;
Anderson, DT ;
Langer, T .
JOURNAL OF ARTHROPLASTY, 2002, 17 (08) :1040-1048
[6]   Tibial component fixation in total knee arthroplasty - A comparison of pegged and stemmed designs [J].
Bertin, Kim C. .
JOURNAL OF ARTHROPLASTY, 2007, 22 (05) :670-678
[7]   TOTAL KNEE ARTHROPLASTY IN THE MANAGEMENT OF PROXIMAL TIBIAL STRESS-FRACTURES [J].
TOMLINSON, MPW ;
DINGWALL, IM ;
PHILLIPS, H .
JOURNAL OF ARTHROPLASTY, 1995, 10 (05) :707-713
[8]   Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial [J].
Bobyn, JD ;
Stackpool, GJ ;
Hacking, SA ;
Tanzer, M ;
Krygier, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05) :907-914
[9]   Tissue response to porous tantalum acetabular cups - A canine model [J].
Bobyn, JD ;
Toh, KK ;
Hacking, SA ;
Tanzer, M ;
Krygier, JJ .
JOURNAL OF ARTHROPLASTY, 1999, 14 (03) :347-354
[10]   Cemented tibial component fixation performs better than cementless fixation -: A randomized radiostereometric study comparing porous-coated, hydroxyapatite-coated and cemented tibial components over 5 years [J].
Carlsson, Å ;
Björkman, A ;
Besjakov, J ;
Önsten, I .
ACTA ORTHOPAEDICA, 2005, 76 (03) :362-369