Magnetic resonance imaging of joint replacements

被引:28
作者
Naraghi, AM
White, LM
机构
[1] Mt Sinai Hosp, Toronto, ON M5G 1X5, Canada
[2] Univ Hlth Network, Dept Diagnost Imaging, Toronto, ON M5G 1X5, Canada
[3] Royal London Hosp, Dept Diagnost Imaging, London E1 1BB, England
关键词
magnetic resonance imaging; artifacts; arthroplasty;
D O I
10.1055/s-2006-934220
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An increasing number of joint replacements are being performed annually. Complications of joint arthroplasty are diverse and may involve the hardware as well as osseous and soft tissue components. Although modalities such as conventional radiography and scintigraphy remain the mainstay of radiological investigation, in some cases these traditional methods of imaging may be negative or underestimate the extent of disease. Magnetic resonance imaging (MRT.) has been considered of limited benefit following arthroplasty because of severe image degradation caused by metallic components. However, with modification of pulse sequences, artifact reduction and improved visualization of periprosthetic tissues are achievable, enabling a comprehensive assessment of articular and nonarticular pathologies. The common artifacts in the presence of orthopedic hardware, optimization of pulse sequences to minimize metal-related artifacts, and the clinical uses of MRI following joint replacement, particularly with regard to total hip arthroplasty, total knee arthroplasty, and shoulder arthroplasty, are reviewed.
引用
收藏
页码:98 / 106
页数:9
相关论文
共 49 条
[1]  
*AM AC ORTH SURG, 1991, ARTHR TOT JOINT REPL
[2]   AN IN-VITRO STUDY AT LOW-FIELD FOR MR GUIDANCE OF A BIOPSY NEEDLE [J].
ARBOGASTRAVIER, S ;
GANGI, A ;
CHOQUET, P ;
BRUNOT, B ;
CONSTANTINESCO, A .
MAGNETIC RESONANCE IMAGING, 1995, 13 (02) :321-324
[3]   SUSCEPTIBILITY ARTIFACTS IN 2DFT SPIN-ECHO AND GRADIENT-ECHO IMAGING - THE CYLINDER MODEL REVISITED [J].
BAKKER, CJG ;
BHAGWANDIEN, R ;
MOERLAND, MA ;
FUDERER, M .
MAGNETIC RESONANCE IMAGING, 1993, 11 (04) :539-548
[4]  
Bozic KJ, 2004, CLIN ORTHOP RELAT R, P18
[5]  
CABRER RP, 2004, MAGN RESON IMAGING, V22, P1097
[6]   Why knees fail - Lessons learned [J].
Callaghan, JJ ;
O'Rourke, MR ;
Saleh, KJ .
JOURNAL OF ARTHROPLASTY, 2004, 19 (04) :31-34
[7]   TOTAL HIP-REPLACEMENT IN PATIENTS YOUNGER THAN 30 YEARS OLD - A 5-YEAR FOLLOW-UP-STUDY [J].
CHANDLER, HP ;
REINECK, FT ;
WIXSON, RL ;
MCCARTHY, JC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (09) :1426-1434
[8]   Use of magnetic resonance imaging in the diagnosis of an occult fracture of the femoral component after total hip arthroplasty [J].
Cook, SM ;
Pellicci, PM ;
Potter, HG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (01) :149-153
[9]  
Czerny C, 1999, Top Magn Reson Imaging, V10, P214, DOI 10.1097/00002142-199908000-00003
[10]  
CZERVIONKE LF, 1988, AM J NEURORADIOL, V9, P1149