Global calibration method for a multi-sensor measurement system based on structured light stereo vision

被引:1
|
作者
Lin, Junyi [1 ]
Jiang, Kaiyong [1 ]
Huang, Changbiao [1 ]
Liu, Bin [1 ]
机构
[1] Huaqiao Univ, Mold & Die Technol & Res Ctr, Xiamen 361021, Fujian, Peoples R China
来源
AUTOMATIC MANUFACTURING SYSTEMS II, PTS 1 AND 2 | 2012年 / 542-543卷
关键词
multi-sensors measurement system; structured light stereo vision; global calibration; common planar template; CAMERA CALIBRATION;
D O I
10.4028/www.scientific.net/AMR.542-543.684
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The global calibration of multi-sensor measurement system is difficult to accomplish, usually, it needs external high-precision measurement equipment. A novel global calibration method based on common planar template is proposed. Stereo vision combined with laser linear-structured light is adopted to constitute a 3D vision sensor system (3DVSS). Stereo calibration of the 3DVSS can be finished by the planar template calibration method. For the global calibration of multiple vision sensors, it only needs a common planar template which is one of the planar templates can be seen synchronously by every camera in 3DVSS. The homography matrix between the coordinate systems of the 3DVSS and the common planer template can be calculated. The global coordinate is established in the common planar template, so the local coordinate system (LCS) of each 3DVSS can be transformed to the global coordinate system (GCS) through the common planar template. Two experiments have been used to test the proposed method, and the experimental results show that the proposed method is flexible and effective.
引用
收藏
页码:684 / 689
页数:6
相关论文
共 50 条
  • [31] Structured light stereo vision system research
    Wang, Zhiyuan
    Xue, Bin
    Li, Zhicong
    AOPC 2020: OPTICAL SENSING AND IMAGING TECHNOLOGY, 2020, 11567
  • [32] A Calibration Method of Monocular Stereo Vision System for On-machine Measurement
    Wang, Zhongren
    Deng, Lijun
    INTERNATIONAL CONFERENCE ON IMAGE PROCESSING AND PATTERN RECOGNITION IN INDUSTRIAL ENGINEERING, 2010, 7820
  • [33] Online calibration for a stereo vision measurement system
    Yu, ZJ
    Ma, SY
    Che, RS
    Wang, QZ
    Tian, W
    Li, ZH
    Li, JZ
    MEASUREMENT TECHNOLOGY AND INTELLIGENT INSTRUMENTS VI, 2005, 295-296 : 723 - 728
  • [34] Online calibration of stereo vision measurement system
    School of Electromechanical Engineering, Henan University of Science and Technology, Luoyang, Henan 471003, China
    不详
    不详
    Guangxue Xuebao, 2009, 6 (1546-1551):
  • [35] New calibration method of line structured light vision system and application for vibration measurement and control
    Qiu Z.-C.
    Xiao J.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2019, 27 (01): : 230 - 240
  • [36] A Novel Calibration Method Based on Vanishing Points and Lines for Linear Structured Light Vision Sensor
    Liu, Yan
    Wu, Dong
    Li, Wei-ran
    Pan, Shu-wen
    2018 2ND INTERNATIONAL CONFERENCE ON APPLIED MATHEMATICS, MODELING AND SIMULATION (AMMS 2018), 2018, 305 : 149 - 158
  • [37] Calibration method for line-structured light vision sensor based on a single ball target
    Liu, Zhen
    Li, Xiaojing
    Li, Fengjiao
    Zhang, Guangjun
    OPTICS AND LASERS IN ENGINEERING, 2015, 69 : 20 - 28
  • [38] Calibration method for a line-structured light vision sensor based on a single cylindrical target
    Zhu, Zhenmin
    Wang, Xinyun
    Zhou, Fuqiang
    Cen, Yigang
    APPLIED OPTICS, 2020, 59 (05) : 1376 - 1382
  • [39] Dimensional measurement of hot, large forgings with stereo vision structured light system
    Wang, B.
    Liu, W.
    Jia, Z.
    Lu, X.
    Sun, Y.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 2011, 225 (B6) : 901 - 908
  • [40] A novel method for round steel measurement with a multi-line structured light vision sensor
    Wu, Bin
    Xue, Ting
    Zhang, Tao
    Ye, Shenghua
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (02)