Comparison of aortic pulse wave velocity measured by three techniques: Complior, SphygmoCor and Arteriograph

被引:250
作者
Rajzer, Marek W. [1 ]
Wojciechowska, Wiktoria [1 ]
Klocek, Marek [1 ]
Palka, Ilona [1 ]
Brzozowska-Kiszka, Malgorzata [1 ]
Kawecka-Jaszcz, Kalina [1 ]
机构
[1] Jagiellonian Univ, Coll Med, Dept Cardiol & Hypertens 1, Inst Cardiol, Krakow, Poland
关键词
carotid-femoral pulse wave velocity; pulse traveled distance; pulse wave transit time; Arteriograph; Complior; SphygmoCor;
D O I
10.1097/HJH.0b013e32830a4a25
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background New 2007 European Society of Hypertension guidelines recommend measuring arterial stiffness in patients with arterial hypertension, suggesting a carotid-femoral pulse wave velocity over 12 m/s as an estimate of subclinical organ damage. Considering this cutoff point, it is worth exploring whether or not there are significant differences in results obtained using various techniques for measuring aortic pulse wave velocity. The aim of the study was to compare aortic pulse wave velocity measurements using Complior, SphygmoCor, and Arteriograph devices, and to assess the effect of pulse wave transit time and traveled distance on pulse wave velocity values. Methods Aortic pulse wave velocity was measured on a single visit, using these devices, in randomized order, in a group of 64 patients with grade 1 or 2 arterial hypertension. Results Aortic pulse wave velocity measured using Complior (10.1 +/- 1.7 m/s) was significantly higher than that obtained using SphygmoCor (8.1 +/- 1.1 m/s) or Arteriograph (8.6 +/- 1.3 m/s). No differences were noted between pulse wave velocity measurements using SphygmoCor and Arteriograph. Between-method comparison revealed that differences in traveled distance were significant: Complior versus Arteriograph [0.09 m, Confidence interval (CI): 0.08-0.12 m, P< 0.05], Complior versus SphygmoCor (0.15 m, CI: 0.13-0.16 m, P< 0.05), Arteriograph versus SphygmoCor (0.05 m, CI: 0.03-0.07 m, P< 0.05). No between-method differences were found for transit times. Conclusion Differences in pulse wave velocity obtained by compared devices resulted primarily from using various methods for measuring traveled distance. It appears reasonable to establish uniform principles for the measurement of traveled distance. Because a large number of prognosis/survival studies used direct distance between carotid and femoral sites of pulse wave recording, this distance should be mostly recommended.
引用
收藏
页码:2001 / 2007
页数:7
相关论文
共 23 条
  • [1] Diabetes mellitus and renal failure: effects on large artery stiffness
    Aoun, S
    Blacher, J
    Safar, ME
    Mourad, JJ
    [J]. JOURNAL OF HUMAN HYPERTENSION, 2001, 15 (10) : 693 - 700
  • [2] ASSESSMENT OF ARTERIAL DISTENSIBILITY BY AUTOMATIC PULSE-WAVE VELOCITY-MEASUREMENT - VALIDATION AND CLINICAL-APPLICATION STUDIES
    ASMAR, R
    BENETOS, A
    TOPOUCHIAN, J
    LAURENT, P
    PANNIER, B
    BRISAC, AM
    TARGET, R
    LEVY, BI
    [J]. HYPERTENSION, 1995, 26 (03) : 485 - 490
  • [3] Pulse wave velocity is increased in patients with transient myocardial ischemia
    Baulmann, Johannes
    Homsi, Rami
    Uen, Sakir
    Dusing, Rainer
    Fimmers, Rolf
    Vetter, Hans
    Mengden, Thomas
    [J]. JOURNAL OF HYPERTENSION, 2006, 24 (10) : 2085 - 2090
  • [4] Impact of aortic stiffness on survival in end-stage renal disease
    Blacher, J
    Guerin, AP
    Pannier, B
    Marchais, SJ
    Safar, ME
    London, GM
    [J]. CIRCULATION, 1999, 99 (18) : 2434 - 2439
  • [5] Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients
    Blacher, J
    Asmar, R
    Djane, S
    London, GM
    Safar, ME
    [J]. HYPERTENSION, 1999, 33 (05) : 1111 - 1117
  • [6] Pulse wave reflection is amplified in normotensive patients with autosomal-dominant polycystic kidney disease and normal renal function
    Borresen, Malene L.
    Wang, Dan
    Strandgaard, Svend
    [J]. AMERICAN JOURNAL OF NEPHROLOGY, 2007, 27 (03) : 240 - 246
  • [7] Aortic stiffness is an independent predictor of primary coronary events in hypertensive patients - A longitudinal study
    Boutouyrie, P
    Tropeano, AI
    Asmar, R
    Gautier, I
    Benetos, A
    Lacolley, P
    Laurent, S
    [J]. HYPERTENSION, 2002, 39 (01) : 10 - 15
  • [8] Arterial compliance by cuff sphygmomanometer - Application to hypertension and early changes in subjects at genetic risk
    Brinton, TJ
    Kailasam, MT
    Wu, RA
    Cervenka, JH
    Chio, SS
    Parmer, RJ
    DeMaria, AN
    OConnor, DT
    [J]. HYPERTENSION, 1996, 28 (04) : 599 - 603
  • [9] Aortic pulse-wave velocity and its relationship to mortality in diabetes and glucose intolerance - An integrated index of vascular function?
    Cruickshank, K
    Riste, L
    Anderson, SG
    Wright, JS
    Dunn, G
    Gosling, RG
    [J]. CIRCULATION, 2002, 106 (16) : 2085 - 2090
  • [10] Evaluation of two devices for self-measurement of blood pressure according to the international protocol: the Omron M5-I and the Omron 705IT
    El Assaad, MA
    Topouchian, JA
    Asmar, RG
    [J]. BLOOD PRESSURE MONITORING, 2003, 8 (03) : 127 - 133