Patient dosimetry and a novel approach to establishing Diagnostic Reference Levels in dental radiology

被引:10
|
作者
Walker, Christopher [1 ]
van der Putten, Wit [1 ,2 ]
机构
[1] St Lukes Hosp, Dept Phys, Dublin 6, Ireland
[2] Natl Univ Ireland, Sch Phys, Galway, Ireland
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2012年 / 28卷 / 01期
关键词
Diagnostic Reference Levels; Dental X-ray units; Quality Assurance; Monte-Carlo; Intra-Oral; Pan-oral tomograph;
D O I
10.1016/j.ejmp.2010.12.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Diagnostic Reference Levels provide a method of ensuring that patient doses in medical procedures are kept at acceptable levels. Their application in dentistry can provide an indication of current dose levels and can assist in potentially significant dose reduction in Ireland given the number of patients screened annually. This study involved retrospective analyses of entrance surface dose and dose-width-product measurements obtained in Irish Dental Practices for both Intra-Oral and Panoramic units respectively, followed by comparisons with Monte-Carlo generated computer models of these procedures. Analysis was performed on data from 33 Intra-Oral units for an Adult Mandibular Molar entrance surface dose, 198 readings for a proposed mGy/mAs reference level and 50 Panoramic machines for a dose-width product investigation. The third quartile value of the entrance surface dose for a standard Adult Mandibular Molar Intra-Oral radiograph is (2.40 +/- 0.92)mGy, compared to a computer-modelled value of 2.60 mGy. The third quartile mGy/mAs value for Intra-Oral procedures is (1.03 +/- 0.38)mGy/mAs, compared to a computer-modelled value of 0.75 mGy/mAs. The third quartile dose width product for an Adult Panoramic radiograph is (59.89 +/- 20.97)mGymm, compared to a computer-modeled value of 62.40 mGymm. It is proposed to introduce Diagnostic Reference Levels of 2.4 mGy for an Adult Mandibular Molar Intra-Oral radiograph and 60 mGymm for an Adult Panoramic radiograph. The use of a new reference quantity in Intra-Oral radiology is also suggested. This has a value of 1 mGy/mAs and may be introduced alongside established procedures. These levels can be taken as guides to acceptable doses, but it should be noted that further reductions are practical under ALARA principles. (C) 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 47 条
  • [41] Diagnostic Reference Levels and Monitoring Practice Can Help Reduce Patient Dose From CT Examinations
    Tonkopi, Elena
    Duffy, Susan
    Abdolell, Mohamed
    Manos, Daria
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (05) : 1073 - 1081
  • [42] Local patient dose diagnostic reference levels in pediatric interventional cardiology in Chile using age bands and patient weight values
    Ubeda, Carlos
    Miranda, Patricia
    Vano, Eliseo
    MEDICAL PHYSICS, 2015, 42 (02) : 615 - 622
  • [43] Using diagnostic reference levels to evaluate the improvement of patient dose optimisation and the influence of recent technologies in radiography and computed tomography
    Roch, Patrice
    Celier, David
    Dessaud, Cecile
    Etard, Cecile
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 98 : 68 - 74
  • [44] A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetry A step to QA with in vivo EPID dosimetry
    Moustakis, Christos
    Ebrahimi Tazehmahalleh, Fatemeh
    Elsayad, Khaled
    Fezeu, Francis
    Scobioala, Sergiu
    STRAHLENTHERAPIE UND ONKOLOGIE, 2020, 196 (02) : 182 - 192
  • [45] Patient dose audit of the most frequent radiographic examinations and the proposed local diagnostic reference levels in southwestern Nigeria: Imperative for dose optimisation
    Jibiri, N. N.
    Olowookere, C. J.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2016, 9 (03) : 274 - 281
  • [46] Patient exposure and diagnostic reference levels in operating rooms: a multi-centric retrospective study in over 150 private and public French clinics
    Farah, J.
    Gonzalez-Mendez, L. A.
    Dufay, F.
    Amir, S.
    Royer, B.
    Gabriel, H.
    Noel, A.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (04) : 1024 - 1038
  • [47] A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetryA step to QA with in vivo EPID dosimetry
    Christos Moustakis
    Fatemeh Ebrahimi Tazehmahalleh
    Khaled Elsayad
    Francis Fezeu
    Sergiu Scobioala