Patient dosimetry and a novel approach to establishing Diagnostic Reference Levels in dental radiology

被引:10
|
作者
Walker, Christopher [1 ]
van der Putten, Wit [1 ,2 ]
机构
[1] St Lukes Hosp, Dept Phys, Dublin 6, Ireland
[2] Natl Univ Ireland, Sch Phys, Galway, Ireland
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2012年 / 28卷 / 01期
关键词
Diagnostic Reference Levels; Dental X-ray units; Quality Assurance; Monte-Carlo; Intra-Oral; Pan-oral tomograph;
D O I
10.1016/j.ejmp.2010.12.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Diagnostic Reference Levels provide a method of ensuring that patient doses in medical procedures are kept at acceptable levels. Their application in dentistry can provide an indication of current dose levels and can assist in potentially significant dose reduction in Ireland given the number of patients screened annually. This study involved retrospective analyses of entrance surface dose and dose-width-product measurements obtained in Irish Dental Practices for both Intra-Oral and Panoramic units respectively, followed by comparisons with Monte-Carlo generated computer models of these procedures. Analysis was performed on data from 33 Intra-Oral units for an Adult Mandibular Molar entrance surface dose, 198 readings for a proposed mGy/mAs reference level and 50 Panoramic machines for a dose-width product investigation. The third quartile value of the entrance surface dose for a standard Adult Mandibular Molar Intra-Oral radiograph is (2.40 +/- 0.92)mGy, compared to a computer-modelled value of 2.60 mGy. The third quartile mGy/mAs value for Intra-Oral procedures is (1.03 +/- 0.38)mGy/mAs, compared to a computer-modelled value of 0.75 mGy/mAs. The third quartile dose width product for an Adult Panoramic radiograph is (59.89 +/- 20.97)mGymm, compared to a computer-modeled value of 62.40 mGymm. It is proposed to introduce Diagnostic Reference Levels of 2.4 mGy for an Adult Mandibular Molar Intra-Oral radiograph and 60 mGymm for an Adult Panoramic radiograph. The use of a new reference quantity in Intra-Oral radiology is also suggested. This has a value of 1 mGy/mAs and may be introduced alongside established procedures. These levels can be taken as guides to acceptable doses, but it should be noted that further reductions are practical under ALARA principles. (C) 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 47 条
  • [31] Establishing national clinical diagnostic reference levels and achievable doses for CT examinations in Brazil: A prospective study
    Bernardo, Monica Oliveira
    Karout, Lina
    Morgado, Flavio
    Ebrahimian, Shadi
    Santos, Alair Sarmet
    Amorim, Clarissa
    Muniz Filho, Hilton
    Moscatelli, Antonio
    Muglia, Valdair Francisco
    Schroeder, Henrique
    Sales, Danilo Moulin
    Henschel, Renan Gandolpho
    Valese, Bruno Giovanni
    Kiiper, Felipe
    Cavalcanti, Publio Cesar
    Lucena, Ronaldo
    Jornada, Tiago
    de Paula, Valnir
    Zago, Marcel
    Varella, Ricardo
    Anes, Mauricio
    Pinheiro, Antonio Marcio Alves
    Carvalho, Luiz Claudio de Moura
    Tapajos, Juliana Santana de Melo
    de Almeida, Fernando Antonio
    Applegate, Kimberly
    Paulo, Graciano
    Costa, Paulo Roberto
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 169
  • [32] Attributable patient risk in nuclear medicine procedures and establishment of diagnostic reference levels
    Ribeiro, Julio Cesar de Souza
    de Mendes, Janaina Dutra Silvestre
    de Sa, Lidia V.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (01):
  • [33] Investigation into patient doses for intravenous urography and proposed Irish diagnostic reference levels
    E. M. Carroll
    P. C. Brennan
    European Radiology, 2003, 13 : 1529 - 1533
  • [34] Investigation into patient doses for intravenous urography and proposed Irish diagnostic reference levels
    Carroll, EM
    Brennan, PC
    EUROPEAN RADIOLOGY, 2003, 13 (07) : 1529 - 1533
  • [35] Radiation dose and diagnostic reference levels for four interventional radiology procedures: results of the prospective European multicenter survey EUCLID
    Alexander A. Schegerer
    Guy Frija
    Graciano Paulo
    Werner Jaschke
    Virginia Tsapaki
    Jacques Repussard
    John Damilakis
    European Radiology, 2021, 31 : 9346 - 9360
  • [36] Radiation dose and diagnostic reference levels for four interventional radiology procedures: results of the prospective European multicenter survey EUCLID
    Schegerer, Alexander A.
    Frija, Guy
    Paulo, Graciano
    Jaschke, Werner
    Tsapaki, Virginia
    Repussard, Jacques
    Damilakis, John
    EUROPEAN RADIOLOGY, 2021, 31 (12) : 9346 - 9360
  • [37] PATIENT DOSES IN COMPUTED TOMOGRAPHY: AN ASSESSMENT OF LOCAL DIAGNOSTIC REFERENCE LEVELS IN A LARGE TEACHING HOSPITAL
    Hadnadjev, Darka R.
    Arandjic, Danijela D.
    Stojanovic, Sanja S.
    Ciraj-Bjelac, Olivera F.
    Bozovic, Predrag M.
    Stankovic, Jelena S.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2012, 27 (03) : 305 - 310
  • [38] Updating national diagnostic reference levels for computed tomography in Greece: Challenges on patient protection optimisation
    Simantirakis, George
    Hourdakis, Costas J.
    Kalathaki, Maria
    Liotsou, Vasiliki
    Nikolaou, Magda
    Pafilis, Christos
    Thrapsanioti, Zoi
    Tritakis, Panagiotis
    Carinou, Eleftheria
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 175
  • [39] European Society of Paediatric Radiology Computed Tomography and Dose Task Force: European guidelines on diagnostic reference levels for paediatric imaging
    Claudio Granata
    Erich Sorantin
    Raija Seuri
    Catherine M. Owens
    Pediatric Radiology, 2019, 49 : 702 - 705
  • [40] European Society of Paediatric Radiology Computed Tomography and Dose Task Force: European guidelines on diagnostic reference levels for paediatric imaging
    Granata, Claudio
    Sorantin, Erich
    Seuri, Raija
    Owens, Catherine M.
    PEDIATRIC RADIOLOGY, 2018, 49 (05) : 702 - 705