Study of a wireless power transmission system for an active capsule endoscope

被引:64
作者
Xin, Wenhui [1 ]
Yan, Guozheng [1 ]
Wang, Wenxin [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Precise Engn & Intelligent Microsyst, Shanghai 200030, Peoples R China
关键词
wireless power transmission; inductive coupling; Helmholtz coil; multiple receiving coils; human tissue safety; FABRICATION; DESIGN; MODELS; COILS;
D O I
10.1002/rcs.298
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background An active capsule endoscope (ACE) will consume much more energy than can be power by batteries. Its orientation and position are always undetermined when it continues the natural way down the gastrointestinal track. Methods In order to deliver stable and sufficient energy to ACE safely, a wireless power transmission system based on inductive coupling is presented. The system consists of a Helmholtz primary coil outside and a multiple secondary coils inside the body. The Helmholtz primary coil is driven to generate a uniform alternating magnetic field covering the whole of the alimentary tract, and the multiple secondary coils receive energy regardless of the ACE's position and orientation relative to the generated magnetic field. The human tissue safety of the electromagnetic field generated by transmitting coil was evaluated, based on a high-resolution realistic human model. Results At least 310 mW usable power can be transmitted under the worst geometrical conditions. Outer dimensions of the power receiver, 10 mm diameter x 12 mm; transmitting power, 25 W; resonant frequency, 400 kHz. The maximum specific absorption rate (SAR) and current density of human tissues are 0.329 W/kg and 3.82 A/m(2), respectively, under the basic restrictions of the international Commission on Non-ionizing Radiation Protection (ICNIRP). Conclusions The designed wireless power transmission is shown to be feasible and potentially safe in a future application. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:113 / 122
页数:10
相关论文
共 27 条
[1]   Examination of circuit parameters for stable high efficiency TETS for artificial hearts [J].
Arai, S ;
Miura, H ;
Sato, F ;
Matsuki, H ;
Sato, T .
IEEE TRANSACTIONS ON MAGNETICS, 2005, 41 (10) :4170-4172
[2]   Modelling and design of extremely low frequency uniform magnetic field exposure apparatus for in vivo bioelectromagnetic studies [J].
Cvetkovic, D. ;
Cosic, I. .
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, :1675-1678
[3]   The dielectric properties of biological tissues .3. Parametric models for the dielectric spectrum of tissues [J].
Gabriel, S ;
Lau, RW ;
Gabriel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2271-2293
[4]   High-resolution human anatomy models for advanced electromagnetic field computations [J].
Gjonaj, E ;
Bartsch, M ;
Clemens, M ;
Schupp, S ;
Weiland, T .
IEEE TRANSACTIONS ON MAGNETICS, 2002, 38 (02) :357-360
[5]   Wireless capsule endoscopy [J].
Iddan, G ;
Meron, G ;
Glukhovsky, A ;
Swain, P .
NATURE, 2000, 405 (6785) :417-417
[6]  
International Commission on Non-Ionizing Radiation Protection (ICNIRP), 1997, GUID LIM EXP TIM VAR
[7]  
International Commission on Radiological Protection (ICRP), 1975, REP TASK GROUP REF M
[8]  
JACOBSON B, 1963, MED ELECTRONICS AND BIOL ENGNG, V1, P165, DOI 10.1007/BF02475885
[9]   Locomotion techniques for robotic colonoscopy [J].
Kassim, Irwan ;
Phee, Louis ;
Ng, Wan S. ;
Gong, Feng ;
Dario, Paolo ;
Mosse, Charles A. .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2006, 25 (03) :49-56
[10]   Design and fabrication of a locomotive mechanism for capsule-type endoscopes using shape memory alloys (SMAs) [J].
Kim, B ;
Lee, S ;
Park, JH ;
Park, JO .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2005, 10 (01) :77-86