Precast segmental reinforced concrete walls under eccentric compressive loading: An experimental study

被引:18
作者
Hou, Hetao [1 ]
Ye, Haideng [1 ]
Qu, Bing [1 ,2 ]
Ma, Tianxiang [1 ]
Liu, Xiang [1 ]
Chen, Lei [1 ]
Zhang, Shuhui [3 ]
机构
[1] Shandong Univ, Sch Civil Engn, Jinan 250061, Shandong, Peoples R China
[2] Calif Polytech State Univ San Luis Obispo, Dept Civil & Environm Engn, San Luis Obispo, CA 93407 USA
[3] One Star Grp Co Ltd, Jinan 250014, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Testing; Precast; Concrete wall; Eccentric compressive loading; Strength; PANELS; BEHAVIOR; CFRP;
D O I
10.1016/j.engstruct.2016.01.034
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Precast Segmental Reinforced Concrete Walls (PS-RCWs) are construction units recently developed for modern modular construction. A typical PS-RCW is comprised of cast-in-place concrete enclosed by two precast concrete panels. This paper experimentally investigates performance of the PS-RCWs under eccentric compressive loading. Eight specimens including seven PS-RCW specimens and one conventional cast-in-place reinforced concrete wall specimen were tested. Test results show that the bonding strength between the cast-in-place concrete and precast concrete panels controls the failure modes of the PS-RCWs under eccentric compressive loading. It is found that a PS-RCW with sufficient bonding strength between the cast-in-place concrete and precast concrete panels exhibits the more favorable failure mode in which a plastic zone forms in the wall as a result of the eccentric compressive loading. Testing data also revealed that the classic strain and stress diagrams assumed for reinforced concrete members under eccentric compressive loading can be extended to PS-RCWs. An analytical model recommended in the Chinese National Code for Design of Concrete Structures (GB50010-2012) was found to provide reasonable predictions for strength of the PS-RCWs under eccentric compressive loading and it is recommended for future practice. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:79 / 88
页数:10
相关论文
共 17 条
[1]  
ACI, 2005, Building code requirements for structural concrete (ACI 318-19) and commentary (318R-19)
[2]  
[Anonymous], 2014, 12014 JGJ MIN HOUS U
[3]  
[Anonymous], 2011, DB34T468 MIN HOUS UR
[4]  
[Anonymous], 2012, 50152 GBT MIN HOUS U
[5]   Structural behaviour of eccentrically loaded precast sandwich panels [J].
Benayoune, A. ;
Samad, A. Aziz A. ;
Trikha, D. N. ;
Ali, A. Abdullah Abang ;
Ashrabov, A. A. .
CONSTRUCTION AND BUILDING MATERIALS, 2006, 20 (09) :713-724
[6]   Ultimate compressive strength of Enveloped Laminar Concrete panels [J].
Carrasco, E. V. M. ;
Rodrigues, E. V. ;
Ribeiro, G. O. ;
Queiroz, G. ;
De Paula, F. A. .
CONSTRUCTION AND BUILDING MATERIALS, 2012, 27 (01) :375-381
[7]  
Code for design of concrete structures, 2012, GB50010 MIN HOUS URB
[8]   Experimental tests on seismically damaged composite steel concrete walls retrofitted with CFRP composites [J].
Dan, D. .
ENGINEERING STRUCTURES, 2012, 45 :338-348
[9]   Behaviour of reinforced and concrete-encased composite columns subjected to biaxial bending and axial load [J].
Dundar, Cengiz ;
Tokgoz, Serkan ;
Tanrikulu, A. Kamil ;
Baran, Tarik .
BUILDING AND ENVIRONMENT, 2008, 43 (06) :1109-1120
[10]  
[连星 LIAN Xing], 2009, [合肥工业大学学报. 自然科学版, Journal of Hefei University of Technology. Natural Science], V32, P1219