Free glycerol determination in biodiesel samples using palladium nanoparticles modified glassy carbon electrode associated with solid phase extraction

被引:14
作者
Honorio, Glaucio Gualtieri [1 ]
da Cunha, Jessica Nogueira [1 ]
dos Santos Castro Assis, Kelly Leite [1 ]
de Aguiar, Paula Fernandes [1 ]
de Andrade, Debora Franca [1 ]
de Souza, Cristiane Gimenes [2 ]
d'Avila, Luiz Antonio [2 ]
Archanjo, Braulio S. [3 ]
Achete, Carlos A. [3 ]
Chaar Pradelle, Renata Norah [4 ]
Turkovics, Franck [4 ]
Serralvo Neto, Rafael [4 ]
D'Elia, Eliane [1 ]
机构
[1] Univ Fed Rio de Janeiro, Inst Chem, BR-21941909 Rio De Janeiro, Brazil
[2] Univ Fed Rio de Janeiro, Sch Chem, BR-21941909 Rio De Janeiro, Brazil
[3] Natl Inst Metrol Qual & Technol, BR-25250020 Duque De Caxias, Brazil
[4] PUC Rio ITUC Secretaria, PSA Grp, Rua Marques Sao Vicente 225, BR-22451045 Gavea, RJ, Brazil
关键词
Biodiesel; Free glycerol; Palladium nanoparticles; Cyclic voltammetry; Solid phase extraction; |Validation; SUPPORTED PD NANOPARTICLES; ETHYLENE-GLYCOL; ELECTROOXIDATION; METHANOL; OXIDATION; PLATINUM; CATALYST; NICKEL;
D O I
10.1007/s10008-019-04387-2
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this work, we developed a method for the quantification of free glycerol in biodiesel using electrochemical detection and solid phase extraction (SPE). SPE was performed using commercial stationary silica phase cartridges to isolate free glycerol from the combined glycerol (such as acylglycerols) and the methyl esters. The electrochemical method was performed by cyclic voltammetry in KOH solution using a glassy carbon electrode modified with Pd nanoparticles. The electrodeposition of palladium nanoparticles was optimized with a complete 3(2) factorial design with triplicate at the central point. The analytical performance of the method was evaluated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ), precision (repeatability), and accuracy (recovery). The proposed method exhibits good linearity (R-2 = 0.99525). The LOD and LOQ values were determined visually, the LOD was1.00 x 10(-6)% w/w, and the LOQ was 3.30 x 10(-6)% w/w, presenting better performance compared with other methods described in the literature. The precision was determined by the relative standard deviation (RSD%), and the values obtained were less than 5%. The recovery ranged between 95.8 and 101%. The proposed method proved to be efficient in the quantification of free glycerol in biodiesel, and the results correlate well with the reference method (GC). The results indicate that the method is presented as an alternative to costly and slow GC-based techniques.
引用
收藏
页码:3057 / 3066
页数:10
相关论文
共 50 条
  • [31] Sensitive and selective determination of hydrazine using glassy carbon electrode modified with Pd nanoparticles decorated multiwalled carbon nanotubes
    Behzad Haghighi
    Hassan Hamidi
    Somayyeh Bozorgzadeh
    Analytical and Bioanalytical Chemistry, 2010, 398 : 1411 - 1416
  • [32] Highly sensitive voltammetric determination of hydrochlorothiazide using a glassy carbon electrode modified with Super P carbon black nanoparticles
    Santos-Neto, Domingos R.
    Lopes, Carlos E. C.
    Silva, Gabrielly P.
    Castro, Lizandra N.
    Silva, Joao Pedro C.
    Ferreira, Dianderson C. M.
    Silva, Luiz Ricardo G.
    Dantas, Luiza M. F.
    da Silva, Iranaldo S.
    ANALYTICAL METHODS, 2024, 16 (36) : 6271 - 6278
  • [33] Preparation of a glassy carbon electrode modified with saffron conjugated silver nanoparticles for the sensitive and selective electroanalytical determination of amoxicillin in urine samples
    Sarakatsanou, Christina
    Karastogianni, Sophia
    Girousi, Stella
    ANALYTICAL METHODS, 2023, 15 (35) : 4572 - 4581
  • [34] Lignin modified glassy carbon electrode for the electrochemical determination of histamine in human urine and wine samples
    Degefu, Hulugirgesh
    Amare, Meareg
    Tessema, Merid
    Admassie, Shimelis
    ELECTROCHIMICA ACTA, 2014, 121 : 307 - 314
  • [35] Electrochemical determination of eugenol using a poly-γ-aminobutyric acid modified glassy carbon electrode
    Yin, Mingjing
    Liu, Shanshan
    Ma, Xinying
    Meng, Xiangyan
    Chao, Mingyong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2023, 18 (12):
  • [36] Dopamine sensor based on a glassy carbon electrode modified with a reduced graphene oxide and palladium nanoparticles composite
    Palanisamy, Selvakumar
    Ku, Shuhao
    Chen, Shen-Ming
    MICROCHIMICA ACTA, 2013, 180 (11-12) : 1037 - 1042
  • [37] Square-Wave Voltammetric Determination of Nanomolar Levels of Linuron in Environmental Water Samples Using a Glassy Carbon Electrode Modified with Platinum Nanoparticles within a Dihexadecyl Phosphate Film
    Marreto, Paola D.
    Trench, Aline B.
    Vicentini, Fernando C.
    Figueiredo-Filho, Luiz C. S.
    Medeiros, Roberta A.
    Pereira, Ernesto. C.
    Fatibello-Filho, Orlando
    AUSTRALIAN JOURNAL OF CHEMISTRY, 2015, 68 (05) : 800 - 805
  • [38] Dopamine sensor based on a glassy carbon electrode modified with a reduced graphene oxide and palladium nanoparticles composite
    Selvakumar Palanisamy
    Shuhao Ku
    Shen-Ming Chen
    Microchimica Acta, 2013, 180 : 1037 - 1042
  • [39] Voltammetric determination of dopamine using modified glassy carbon electrode by electrografting of catechol
    Pourghobadi, Zeinab
    Neamatollahi, Davood
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2017, 82 (09) : 1053 - 1061
  • [40] A glassy carbon electrode modified with carboxylated diamond nanoparticles for differential pulse voltammetric simultaneous determination of guanine and adenine
    Habibi, Biuck
    Jahanbakhshi, Mojtaba
    MICROCHIMICA ACTA, 2016, 183 (07) : 2317 - 2325