Free glycerol determination in biodiesel samples using palladium nanoparticles modified glassy carbon electrode associated with solid phase extraction

被引:14
|
作者
Honorio, Glaucio Gualtieri [1 ]
da Cunha, Jessica Nogueira [1 ]
dos Santos Castro Assis, Kelly Leite [1 ]
de Aguiar, Paula Fernandes [1 ]
de Andrade, Debora Franca [1 ]
de Souza, Cristiane Gimenes [2 ]
d'Avila, Luiz Antonio [2 ]
Archanjo, Braulio S. [3 ]
Achete, Carlos A. [3 ]
Chaar Pradelle, Renata Norah [4 ]
Turkovics, Franck [4 ]
Serralvo Neto, Rafael [4 ]
D'Elia, Eliane [1 ]
机构
[1] Univ Fed Rio de Janeiro, Inst Chem, BR-21941909 Rio De Janeiro, Brazil
[2] Univ Fed Rio de Janeiro, Sch Chem, BR-21941909 Rio De Janeiro, Brazil
[3] Natl Inst Metrol Qual & Technol, BR-25250020 Duque De Caxias, Brazil
[4] PUC Rio ITUC Secretaria, PSA Grp, Rua Marques Sao Vicente 225, BR-22451045 Gavea, RJ, Brazil
关键词
Biodiesel; Free glycerol; Palladium nanoparticles; Cyclic voltammetry; Solid phase extraction; |Validation; SUPPORTED PD NANOPARTICLES; ETHYLENE-GLYCOL; ELECTROOXIDATION; METHANOL; OXIDATION; PLATINUM; CATALYST; NICKEL;
D O I
10.1007/s10008-019-04387-2
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this work, we developed a method for the quantification of free glycerol in biodiesel using electrochemical detection and solid phase extraction (SPE). SPE was performed using commercial stationary silica phase cartridges to isolate free glycerol from the combined glycerol (such as acylglycerols) and the methyl esters. The electrochemical method was performed by cyclic voltammetry in KOH solution using a glassy carbon electrode modified with Pd nanoparticles. The electrodeposition of palladium nanoparticles was optimized with a complete 3(2) factorial design with triplicate at the central point. The analytical performance of the method was evaluated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ), precision (repeatability), and accuracy (recovery). The proposed method exhibits good linearity (R-2 = 0.99525). The LOD and LOQ values were determined visually, the LOD was1.00 x 10(-6)% w/w, and the LOQ was 3.30 x 10(-6)% w/w, presenting better performance compared with other methods described in the literature. The precision was determined by the relative standard deviation (RSD%), and the values obtained were less than 5%. The recovery ranged between 95.8 and 101%. The proposed method proved to be efficient in the quantification of free glycerol in biodiesel, and the results correlate well with the reference method (GC). The results indicate that the method is presented as an alternative to costly and slow GC-based techniques.
引用
收藏
页码:3057 / 3066
页数:10
相关论文
共 50 条
  • [21] A new sorbent of modified MWCNT for solid phase extraction and determination of trace amount of palladium in environmental samples
    Ehsan Mohammadifar
    Farzaneh Shemirani
    Behrooz Majidi
    Journal of Analytical Chemistry, 2015, 70 : 136 - 142
  • [22] Electrochemical Sensor for Simple and Sensitive Determination of Hydroquinone in Water Samples Using Modified Glassy Carbon Electrode
    Karami-Kolmoti, Parisa
    Beitollahi, Hadi
    Modiri, Sina
    BIOMEDICINES, 2023, 11 (07)
  • [23] A new sorbent of modified MWCNT for solid phase extraction and determination of trace amount of palladium in environmental samples
    Mohammadifar, Ehsan
    Shemirani, Farzaneh
    Majidi, Behrooz
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (02) : 136 - 142
  • [24] Adsorption Studies and Selective Determination of Epinephrine at Glycerol-Clay Modified Glassy Carbon Electrode
    Agyeman, Augustine O.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (10): : 9601 - 9618
  • [25] Amperometric determination of L-cysteine using a glassy carbon electrode modified with palladium nanoparticles grown on reduced graphene oxide in a Nafion matrix
    Norazriena Yusoff
    Perumal Rameshkumar
    An’amt Mohamed Noor
    Nay Ming Huang
    Microchimica Acta, 2018, 185
  • [26] Determination of sulfonamides in milk samples by HPLC with amperometric detection using a glassy carbon electrode modified with multiwalled carbon nanotubes
    Maria Bueno, Ana
    Maria Contento, Ana
    Rios, Angel
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (04) : 382 - 389
  • [27] Development of an electrochemical sensor for the determination of glycerol based on glassy carbon electrodes modified with a copper oxide nanoparticles/multiwalled carbon nanotubes/pectin composite
    Javier Arevalo, Fernando
    Osuna-Sanchez, Yolanda
    Sandoval-Cortes, Jose
    Di Tocco, Aylen
    Marcelo Granero, Adrian
    Noel Robledo, Sebastian
    Alicia Zon, Maria
    Roberto Vettorazzi, Nelio
    Luis Martinez, Jose
    Patricia Segura, Elda
    Ilina, Anna
    Fernandez, Hector
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 244 : 949 - 957
  • [28] Automatized flow-batch method for fluorescent determination of free glycerol in biodiesel samples using on-line extraction
    Lima, Marcelo B.
    Insausti, Matias
    Domini, Claudia E.
    Pistonesi, Marcelo F.
    Ugulino de Araujo, Mario C.
    Fernandez Band, Beatriz S.
    TALANTA, 2012, 89 : 21 - 26
  • [29] DETERMINATION OF ISONIAZID BY USING ROOM TEMPERATURE IONIC LIQUIDS MODIFIED GLASSY CARBON ELECTRODE
    Behnamipour, S.
    Abbasi, K. H.
    Rouhollahi, A.
    Ardakani, Mazloum M.
    Haghgoo, S.
    Arast, Y.
    ACTA MEDICA MEDITERRANEA, 2016, 32 : 1549 - 1553
  • [30] Determination of p-nitrophenol in Synthetic Textile Wastewater Samples Using a Graphene Oxide/Palladium Nanoparticles Modified Carbon Paste Electrode
    D'Almeida, Suysia R.
    Buoro, Rafael M.
    ELECTROANALYSIS, 2021, 33 (06) : 1623 - 1632