Reliability of Smartphone Pulse Oximetry in Subjects at Risk for Hypoxemia

被引:9
|
作者
Modi, Aashna M. [1 ]
Kiourkas, Renee D. [1 ]
Li, Jie [2 ]
Scott, J. Brady [2 ]
机构
[1] Rush Univ, Resp Care Serv, Med Ctr, Chicago, IL 60607 USA
[2] Rush Univ, Dept Cardiopulm Sci, Div Resp Care, Chicago, IL 60607 USA
关键词
smartphone; heart rate; S-pO2; hypoxemia; 6-min walk test; monitoring; pulse oximetry;
D O I
10.4187/respcare.07670
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Pulse oximeters are used to measure S-pO2 and pulse rate. These devices are either standalone machines or integrated into physiologic monitoring systems. Some smartphones now have pulse oximetry capabilities. Because it is possible that some patients might utilize this technology, we sought to assess the accuracy and usability of smartphone pulse oximeters. METHODS: This was a prospective, observational study that involved noninvasive measurements of S-pO2 and heart rate with 3 devices: Masimo Radical-7, Kenek Edge with the Apple iPhone 6S, and the Samsung S8 smartphone. Ambulatory adult patients visiting our institution's pulmonary function lab for a 6-min walk test were eligible to participate in the study. Pretest and posttest results for each subject were obtained simultaneously using all 3 devices. All results were analyzed with the Spearman rho correlation test, and Bland-Altman plots were used to assess the agreement of measures between the devices. RESULTS: Forty-seven subjects were enrolled in the study, with pulmonary hypertension (30%) and COPD (23%) being the 2 major diagnoses. The mean +/- SD difference between the Masimo and Apple devices for pretest S-pO2 was 2.3 +/- 2.4%, and the difference for posttest S-pO2 was 2.1 +/- 3.9%. The mean difference between the Masimo and Samsung devices for pretest S-pO2 was 3.2 +/- 2.8%, and the difference for posttest S-pO2 was 2.4 +/- 3.5%. The number of subjects who were unable to obtain was higher with the Samsung device than with the Apple device in both pretest (14 of 47 vs 3 of 47) and posttest (17 of 47 vs 5 of 47). In contrast, the Masimo device was able to measure S1, in all subjects. CONCLUSIONS: Smartphone pulse oximeters were unreliable compared to a hospital pulse oximeter. Further research is needed with evolving technology to better understand smartphone pulse oximetry.
引用
收藏
页码:384 / 390
页数:7
相关论文
共 50 条
  • [1] Pulse oximetry: Utility in detecting arterial hypoxemia in subjects with cirrhosis.
    Abrams, GA
    Fallon, MB
    Nail, C
    McGuire, BM
    Van Leeuwen, DJ
    Eckhoff, DE
    Bynon, SJ
    Bloomer, JR
    HEPATOLOGY, 1999, 30 (04) : 435A - 435A
  • [2] Smartphone camera oximetry in an induced hypoxemia study
    Hoffman, Jason S.
    Viswanath, Varun K.
    Tian, Caiwei
    Ding, Xinyi
    Thompson, Matthew J.
    Larson, Eric C.
    Patel, Shwetak N.
    Wang, Edward J.
    NPJ DIGITAL MEDICINE, 2022, 5 (01)
  • [3] Smartphone camera oximetry in an induced hypoxemia study
    Jason S. Hoffman
    Varun K. Viswanath
    Caiwei Tian
    Xinyi Ding
    Matthew J. Thompson
    Eric C. Larson
    Shwetak N. Patel
    Edward J. Wang
    npj Digital Medicine, 5
  • [4] Pulse oximetry reliability for detection of hypoxemia under motion in extremely premature infants
    Alaleh Dormishian
    Alini Schott
    Ana Cecilia Aguilar
    Eduardo Bancalari
    Nelson Claure
    Pediatric Research, 2023, 93 : 118 - 124
  • [5] Pulse oximetry reliability for detection of hypoxemia under motion in extremely premature infants
    Dormishian, Alaleh
    Schott, Alini
    Aguilar, Ana Cecilia
    Bancalari, Eduardo
    Claure, Nelson
    PEDIATRIC RESEARCH, 2023, 93 (01) : 118 - 124
  • [6] ACCURACY OF PULSE OXIMETRY DURING HYPOXEMIA
    THRUSH, D
    HODGES, MR
    SOUTHERN MEDICAL JOURNAL, 1994, 87 (04) : 518 - 521
  • [7] An Observational Study of the Risk Assessment of Severe Pneumonia for Prediction of Hypoxemia by Pulse Oximetry
    Singhal, Siddhant
    Kumar, Rekha
    Mahapatra, Chinmaya
    Jangid, Roshan
    Laxminath, T. Karthik
    JOURNAL OF PEDIATRICS REVIEW, 2021, 9 (04)
  • [8] PERIOPERATIVE HYPOXEMIA DETECTED BY INTERMITTENT PULSE OXIMETRY
    MCKENZIE, AJ
    ANAESTHESIA AND INTENSIVE CARE, 1989, 17 (04) : 412 - 417
  • [9] PULSE OXIMETRY FOR HYPOXEMIA - A WARNING TO USERS AND MANUFACTURERS
    FANCONI, S
    INTENSIVE CARE MEDICINE, 1989, 15 (08) : 540 - 542
  • [10] PULSE OXIMETRY IN VENTILATED PRETERM NEWBORNS - RELIABILITY OF DETECTION OF HYPEROXAEMIA AND HYPOXEMIA, AND FEASIBILITY OF ALARM SETTINGS
    PAKY, F
    KOECK, CM
    ACTA PAEDIATRICA, 1995, 84 (06) : 613 - 616