Canonical correlation analysis applied to remove muscle artifacts from the electroencephalogram

被引:377
作者
De Clercq, Wim [1 ]
Vergult, Anneleen
Vanrumste, Bart
Van Paesschen, Wim
Van Huffel, Sabine
机构
[1] Katholieke Univ Leuven, Dept Elect Engn, ESAT, SCD,SISTA, B-3001 Louvain, Belgium
[2] Univ Hosp Gasthuisberg, Dept Neurol, B-3000 Louvain, Belgium
关键词
blind source separation; canonical correlation analysis; EEG; muscle artifact removal; INDEPENDENT COMPONENT ANALYSIS; BLIND SOURCE SEPARATION; EEG;
D O I
10.1109/TBME.2006.879459
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The electroencephalogram (EEG) is often contaminated by muscle artifacts. In this paper, a new method for muscle artifact removal in EEG is presented, based on canonical correlation analysis (CCA) as a blind source separation (BSS) technique. This method is demonstrated on a synthetic data set. The method outperformed a low-pass filter with different cutoff frequencies and an independent component analysis (ICA)-based technique for muscle artifact removal. In addition, the method is applied on a real ictal EEG recording contaminated with muscle artifacts. The proposed method removed successfully the muscle artifact without altering the recorded underlying ictal activity.
引用
收藏
页码:2583 / 2587
页数:5
相关论文
共 17 条
[1]  
[Anonymous], P INT C ART NEUR NET
[2]  
[Anonymous], 2001, LIUIMTEX0062 DEP BIO
[3]   A blind source separation technique using second-order statistics [J].
Belouchrani, A ;
AbedMeraim, K ;
Cardoso, JF ;
Moulines, E .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1997, 45 (02) :434-444
[4]   High-order contrasts for independent component analysis [J].
Cardoso, JF .
NEURAL COMPUTATION, 1999, 11 (01) :157-192
[5]  
De Clercq W, 2005, EPILEPSIA, V46, P378
[6]   Exploratory fMRI analysis by autocorrelation maximization [J].
Friman, O ;
Borga, M ;
Lundberg, P ;
Knutsson, H .
NEUROIMAGE, 2002, 16 (02) :454-464
[7]  
Friman O, 2001, MAGNET RESON MED, V45, P323, DOI 10.1002/1522-2594(200102)45:2<323::AID-MRM1041>3.0.CO
[8]  
2-#
[9]  
FRIMAN O, 2003, THESIS LINKOPINGS U
[10]   EMG contamination of EEG: spectral and topographical characteristics [J].
Goncharova, II ;
McFarland, DJ ;
Vaughan, TM ;
Wolpaw, JR .
CLINICAL NEUROPHYSIOLOGY, 2003, 114 (09) :1580-1593