Gadolinium-Based Contrast Agents and NSF: Evidence from Animal Experience

被引:80
作者
Sieber, Martin A. [1 ]
Steger-Hartmann, Thomas [2 ]
Lengsfeld, Philipp [3 ]
Pietsch, Hubertus [1 ]
机构
[1] Bayer Schering Pharma AG, Diagnost Imaging Res, D-13342 Berlin, Germany
[2] Bayer Schering Pharma AG, Nonclin Drug Safety, D-13342 Berlin, Germany
[3] Bayer Schering Pharma AG, Global Med Affairs Diagnost Imaging, D-13342 Berlin, Germany
关键词
nephrogenic systemic fibrosis; rodent models; Gadolinium; Magnetic Resonance Imaging; Gadolinium based Contrast Agents; NEPHROGENIC SYSTEMIC FIBROSIS; LONG-TERM RETENTION; GADODIAMIDE INJECTION; SKIN; PHARMACOKINETICS; BIODISTRIBUTION; PATHOGENESIS; STABILITY; TOXICITY; TRIGGER;
D O I
10.1002/jmri.21971
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Nephrogenic systemic fibrosis (NSF) is a potentially severe systemic disease typically characterized by fibrosis of the skin and connective tissues. The etiology of NSF is still unknown but is likely to be multifactorial. Specific triggers under scientific evaluation have included surgery and/or the occurrence of thrombosis or other vascular injury, proinflammatory state, the administration of high doses of erythropoietin, and more recently the use of gadolinium-based contrast agents (GBCAs). The aim of this review is to summarize knowledge regarding the pathogenesis of NSF and the potential role of GBCAs in its pathology, with a focus on animal experiments. The potential role of complex stability of GCBAs will be highlighted by results from several in vitro and in vivo experiments in rodent models of NSF.
引用
收藏
页码:1268 / 1276
页数:9
相关论文
共 50 条
  • [31] Generic gadolinium-based contrast agents: the future?
    Thomsen, Henrik S.
    ACTA RADIOLOGICA, 2017, 58 (11) : 1285 - 1287
  • [32] Gadolinium-based contrast agents: why nephrologists need to be concerned
    Leyba, Katarina
    Wagner, Brent
    CURRENT OPINION IN NEPHROLOGY AND HYPERTENSION, 2019, 28 (02) : 154 - 162
  • [33] Gadolinium-based contrast agents in pediatric magnetic resonance imaging
    Gale, Eric M.
    Caravan, Peter
    Rao, Anil G.
    McDonald, Robert J.
    Winfeld, Matthew
    Fleck, Robert J.
    Gee, Michael S.
    PEDIATRIC RADIOLOGY, 2017, 47 (05) : 507 - 521
  • [34] The Impact of Excess Ligand on the Retention of Nonionic, Linear Gadolinium-Based Contrast Agents in Patients With Various Levels of Renal Dysfunction: A Review and Simulation Analysis
    Prybylski, John P.
    Jay, Michael
    ADVANCES IN CHRONIC KIDNEY DISEASE, 2017, 24 (03) : 176 - 182
  • [35] Pharmacokinetics of gadolinium-based contrast agents
    Czock, D.
    RADIOLOGE, 2019, 59 (05): : 408 - 412
  • [36] Artificial Contrast Deep Learning for Reducing Gadolinium-Based Contrast Agents in Neuroradiology
    Haase, Robert
    Pinetz, Thomas
    Kobler, Erich
    Paech, Daniel
    Effland, Alexander
    Radbruch, Alexander
    Deike-Hofmann, Katerina
    INVESTIGATIVE RADIOLOGY, 2023, 58 (08) : 539 - 547
  • [37] Organ retention of gadolinium in mother and pup mice: effect of pregnancy and type of gadolinium-based contrast agents
    Erdene, Khongorzul
    Nakajima, Takahito
    Kameo, Satomi
    Khairinisa, Miski Aghnia
    Lamid-Ochir, Oyunbold
    Tumenjargal, Amartuvshin
    Koibuchi, Noriyuki
    Koyama, Hiroshi
    Tsushima, Yoshito
    JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (10) : 568 - 573
  • [38] MR Imaging Safety Considerations of Gadolinium-Based Contrast Agents Gadolinium Retention and Nephrogenic Systemic Fibrosis
    McDonald, Jennifer S.
    McDonald, Robert J.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2020, 28 (04) : 497 - +
  • [39] Gadolinium Concentrations in Biological Matrices From Patients Exposed to Gadolinium-Based Contrast Agents
    Layne, Kerry A.
    Raja, Kishor
    Dargan, Paul I.
    Wood, David M.
    INVESTIGATIVE RADIOLOGY, 2021, 56 (07) : 458 - 464
  • [40] Gadolinium-based contrast agents: A comprehensive risk assessment
    Fraum, Tyler J.
    Ludwig, Daniel R.
    Bashir, Mustafa R.
    Fowler, Kathryn J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (02) : 338 - 353