Hemodynamics of left internal mammary artery bypass graft: Effect of anastomotic geometry, coronary artery stenosis, and postoperative time

被引:26
作者
Fan, Tingting [1 ,2 ]
Lu, Yuan [3 ]
Gao, Yan [4 ]
Meng, Jie [4 ]
Tan, Wenchang [1 ,2 ,5 ]
Huo, Yunlong [1 ,2 ]
Kassab, Ghassan S. [6 ]
机构
[1] Peking Univ, Coll Engn, Mech & Engn Sci, Beijing, Peoples R China
[2] Peking Univ, Coll Engn, State Key Lab Turbulence & Complex Syst, Beijing, Peoples R China
[3] Xuzhou Med Coll, Affiliated Hosp, Xuzhou, Peoples R China
[4] Hebei Univ, Affiliated Hosp, Baoding, Peoples R China
[5] Peking Univ, Shenzhen Grad Sch, Shenzhen, Peoples R China
[6] Calif Med Innovat Inst, 11107 Roselle St,Rm 211, San Diego, CA USA
基金
中国国家自然科学基金;
关键词
Wall shear stress; Oscillatory shear index; Flow pattern; CABG; ASSOCIATION TASK-FORCE; WALL SHEAR-STRESS; BLOOD-FLOW; COMPETITIVE FLOW; DISEASE; PATENCY; SURGERY; ANGLE; ANGIOGRAPHY; DIAMETER;
D O I
10.1016/j.jbiomech.2016.01.031
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Although the left internal mammary artery (LIMA) bypass graft is the best choice for surgical revascularization, its hemodynamics are still complex and can result in long-term graft failure. Here, we performed a hemodynamic analysis of the LIMA-coronary artery with end-to-side/side-to-side anastomoses based on 15 patient-specific CTA images at various postoperative periods. We hypothesize that hemodynamic patterns are determined by the interplay of LIMA geometry, anastomotic configuration, and severity of native coronary artery stenosis, which are strongly affected by the postoperative time. A 3D finite volume method with the inlet pressure wave and outlet resistance boundary conditions was used to compute the distribution of pressure and flow, from which the time-averaged wall shear stress (TAWSS), oscillation shear index (OSI), time-averaged WSS gradient (TAWSSG), and transverse WSS (transWSS) were determined. To characterize the hemodynamic environment, we defined surface area ratios of low TAWSS (<= 4 dynes/cm(2)), high OSI (>= 0.15), TAWSSG (>= 500 dynes/cm(3)), and transWSS (>= 6 dynes/cm(2)) in the LIMA graft and at the anastomosis between LIMA graft and coronary artery. These ratios were determined by the interplay of multiple morphometric parameters in the LIMA-coronary artery, but increased with postoperative time. These findings have significant implications for understanding LIMA graft patency. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:645 / 652
页数:8
相关论文
共 35 条
[1]   Long-term patency of internal mammary artery bypass grafts - Relationship with preoperative severity of the native coronary artery stenosis [J].
Berger, A ;
MacCarthy, PA ;
Siebert, U ;
Carlier, S ;
Wijns, W ;
Heyndrickx, G ;
Bartunek, J ;
Vanermen, H ;
De Bruyne, B .
CIRCULATION, 2004, 110 (11) :II36-II40
[2]   Hemodynamic shear stress and the endothelium in cardiovascular pathophysiology [J].
Davies, Peter F. .
NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2009, 6 (01) :16-26
[3]   THE EFFECT OF ANGLE AND FLOW-RATE UPON HEMODYNAMICS IN DISTAL VASCULAR GRAFT ANASTOMOSES - A NUMERICAL-MODEL STUDY [J].
FEI, DY ;
THOMAS, JD ;
RITTGERS, SE .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (03) :331-336
[4]   Flow and wall shear stress in end-to-side and side-to-side anastomosis of venous coronary artery bypass grafts [J].
Frauenfelder, Thomas ;
Boutsianis, Evangelos ;
Schertler, Thomas ;
Husmann, Lars ;
Leschka, Sebastian ;
Poulikakos, Dimos ;
Marincek, Borut .
BIOMEDICAL ENGINEERING ONLINE, 2007, 6 (1)
[5]   Severity of coronary artery stenosis at preoperative angiography and midterm mammary graft status [J].
Gaudino, M ;
Alessandrini, F ;
Nasso, G ;
Bruno, P ;
Manzoli, A ;
Possati, G .
ANNALS OF THORACIC SURGERY, 2002, 74 (01) :119-121
[6]   Long-term patency of saphenous vein and left internal mammary artery grafts after coronary artery bypass surgery - Results from a department of veterans affairs cooperative study [J].
Goldman, S ;
Zadina, K ;
Moritz, T ;
Ovitt, T ;
Sethi, G ;
Copeland, JG ;
Thottapurathu, L ;
Krasnicka, B ;
Ellis, N ;
Anderson, RJ ;
Henderson, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (11) :2149-2156
[7]   Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: A review [J].
Hiroaki Haruguchi ;
Satoshi Teraoka .
Journal of Artificial Organs, 2003, 6 (4) :227-235
[8]   Effects of competitive blood flow on arterial graft patency and diameter - Medium-term postoperative follow-up [J].
Hashimoto, H ;
Isshiki, T ;
Ikari, Y ;
Hara, K ;
Saeki, F ;
Tamura, T ;
Yamaguchi, T ;
Suma, H .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (02) :399-407
[9]  
Hillis LD, 2011, CIRCULATION, V124, P2610, DOI 10.1161/CIR.0b013e31823b5fee
[10]   Flow patterns in three-dimensional porcine epicardial coronary arterial tree [J].
Huo, Yunlong ;
Wischgoll, Thomas ;
Kassab, Ghassan S. .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2007, 293 (05) :H2959-H2970