摘要
CSIR-NPL, India (NPLI) has developed its first Cesium atomic fountain (NPLI-CsF1). The indigenously developed fountain frequency standard is now fully operational and its frequency is now being evaluated along with all systematic and statistical uncertainties. Seven frequency evaluations have been recently conducted to estimate fountain frequency with respect to UTC (Coordinate Universal Time). The fountain frequency is compared with the Hydrogen MASER frequency which is contributing to UTC and hence fountain frequency is evaluated with respect to the UTC The fountain frequency is stable to few parts in 10(15) at <1 day averaging time.
引用
收藏
页码:67 / 76
页数:10
相关论文
共 50 条
  • [1] Systematic Uncertainty Evaluation of the Cesium Fountain Primary Frequency Standard at NPL India
    Aishik Acharya
    Vattikonda Bharath
    Poonam Arora
    Suchi Yadav
    Ashish Agarwal
    Amitava Sen Gupta
    MAPAN, 2017, 32 : 67 - 76
  • [2] PROGRESS IN BUILDING OF CESIUM FOUNTAIN FREQUENCY STANDARD AT NPL, INDIA
    Sen Gupta, Amitava
    Agarwal, Ashish
    Arora, Poonam
    Pant, Kavindra
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 76 - 77
  • [3] Detection, Acquisition and Processing of Fluorescence from Cold Atoms in Cesium Fountain Primary Frequency Standard at NPL, India
    Aishik Acharya
    Poonam Arora
    Suchi Yadav
    Amitava Sen Gupta
    MAPAN, 2020, 35 : 521 - 530
  • [4] Detection, Acquisition and Processing of Fluorescence from Cold Atoms in Cesium Fountain Primary Frequency Standard at NPL, India
    Acharya, Aishik
    Arora, Poonam
    Yadav, Suchi
    Sen Gupta, Amitava
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2020, 35 (04): : 521 - 530
  • [5] Accuracy evaluation of a cesium fountain primary frequency standard at NIST
    Meekhof, DM
    Jefferts, SR
    Stepanovíc, M
    Parker, TE
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (02) : 507 - 509
  • [6] First uncertainty evaluation of the cesium fountain primary frequency standard NMIJ-F2
    Takamizawa, Akifumi
    Yanagimachi, Shinya
    Hagimoto, Ken
    METROLOGIA, 2022, 59 (03)
  • [7] First uncertainty evaluation of the cesium fountain primary frequency standard NMIJ-F2
    Takamizawa, Akifumi
    Yanagimachi, Shinya
    Hagimoto, Ken
    Metrologia, 2022, 59 (03):
  • [8] Accuracy evaluation of a cesium fountain primary frequency standard at NIST
    Meekhof, DM
    Jefferts, SR
    Shirley, JH
    Parker, TE
    2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 311 - 312
  • [9] Initial evaluation of the NPL caesium fountain frequency standard
    Szymaniec, K
    Chalupczak, W
    Henderson, D
    PROCEEDINGS OF THE 2003 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & PDA EXHIBITION JOINTLY WITH 17TH EUROPEAN FREQUENCY AND TIME FORUM, 2003, : 112 - 114
  • [10] Uncertainty evaluation of the continuous cesium fountain frequency standard FOCS-2
    Di Domenico, Gianni
    Devenoges, Laurent
    Joyet, Alain
    Stefanov, Andre
    Thomann, Pierre
    2011 JOINT CONFERENCE OF THE IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM/EUROPEAN FREQUENCY AND TIME FORUM PROCEEDINGS, 2011, : 51 - 55