Corrosion Behavior of Steel-Reinforced Green Concrete Containing Recycled Coarse Aggregate Additions in Sulfate Media

被引:10
作者
Landa-Sanchez, Abigail [1 ]
Bosch, Juan [2 ]
Baltazar-Zamora, Miguel Angel [3 ]
Croche, Rene [4 ]
Landa-Ruiz, Laura [3 ]
Santiago-Hurtado, Griselda [5 ]
Moreno-Landeros, Victor M. [5 ]
Olguin-Coca, Javier [6 ]
Lopez-Leon, Luis [6 ]
Bastidas, Jose M. [7 ]
Mendoza-Rangel, Jose M. [3 ,8 ]
Ress, Jacob [2 ]
Bastidas, David. M. [2 ]
机构
[1] Univ Veracruzana, Doctorado Ingn, Fac Ingn Mecan & Elect, Xalapa 91000, Veracruz, Mexico
[2] Univ Akron, Dept Chem Biomol & Corros Engn, Natl Ctr Educ & Res Corros & Mat Performance, 302 E Buchtel Ave, Akron, OH 44325 USA
[3] Univ Veracruzana, Fac Ingn Civil Xalapa, Lomas Estadio S-N, Xalapa 91000, Veracruz, Mexico
[4] Univ Veracruzana, Fac Ingn Mecan & Elect, Xalapa 91000, Veracruz, Mexico
[5] UADEC, Fac Ingn Civil, Unidad Torreon, Torreon 27276, Mexico
[6] UAEH, Inst Ciencias Basicas & Ingn, Grp Invest DICSO, Pachuca 42082, Hidalgo, Mexico
[7] CSIC, Natl Ctr Met Res CENIM, Ave Gregorio Amo 8, Madrid 28040, Spain
[8] Univ Autonoma Nuevo Leon, Fac Ingn Civil, Ave Pedro Alba S-N, San Nicolas De Los Garza 66455, Nuevo Leon, Mexico
关键词
corrosion; AISI; 304; SS; 1018; CS; green concrete; recycled coarse aggregate; sugar cane bagasse ash; Na2SO4; NICKEL STAINLESS-STEEL; BAGASSE ASH; FLY-ASH; ELECTROCHEMICAL EVALUATION; ELECTRICAL-RESISTIVITY; DURABILITY PROPERTIES; BOND STRENGTH; CARBON-STEEL; GEOPOLYMER; RESISTANCE;
D O I
10.3390/ma13194345
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Novel green concrete (GC) admixtures containing 50% and 100% recycled coarse aggregate (RCA) were manufactured according to the ACI 211.1 standard. The GC samples were reinforced with AISI 1080 carbon steel and AISI 304 stainless steel. Concrete samples were exposed to 3.5 wt.% Na2SO4 and control (DI-water) solutions. Electrochemical testing was assessed by corrosion potential (E-corr) according to the ASTM C-876-15 standard and a linear polarization resistance (LPR) technique following ASTM G59-14. The compressive strength of the fully substituted GC decreased 51.5% compared to the control sample. Improved corrosion behavior was found for the specimens reinforced with AISI 304 SS; the corrosion current density (i(corr)) values of the fully substituted GC were found to be 0.01894 mu A/cm(2) after Day 364, a value associated with negligible corrosion. The 50% RCA specimen shows good corrosion behavior as well as a reduction in environmental impact. Although having lower mechanical properties, a less dense concrete matrix and high permeability, RCA green concrete presents an improved corrosion behavior thus being a promising approach to the higher pollutant conventional aggregates.
引用
收藏
页码:1 / 20
页数:20
相关论文
共 109 条
[1]  
ACI. Committee, 2011, 214R11 ACI
[2]   Production of low cost self compacting concrete using bagasse ash [J].
Akram, Tayyeb ;
Memon, Shazim Ali ;
Obaid, Humayun .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (02) :703-712
[3]   Corrosion Resistance of Recycled Aggregate Concrete Incorporating Slag [J].
Al-Yaqout, Anwar ;
El-Hawary, Moetaz ;
Nouh, Khallad ;
Khan, Pattan Bazieth .
ACI MATERIALS JOURNAL, 2020, 117 (03) :111-122
[4]   Chloride-induced reinforcing steel corrosion in ternary concretes containing fly ash and untreated sugarcane bagasse ash [J].
Alberto Franco-Lujan, Victor ;
Antonio Maldonado-Garcia, Marco ;
Manuel Mendoza-Rangel, Jose ;
Montes-Garcia, Pedro .
CONSTRUCTION AND BUILDING MATERIALS, 2019, 198 :608-618
[5]   Bond strength between corroded steel reinforcement and recycled aggregate concrete [J].
Alhawat, Musab ;
Ashour, Ashraf .
STRUCTURES, 2019, 19 :369-385
[6]   Influence of Glass Fibers on Mechanical Properties of Concrete with Recycled Coarse Aggregates [J].
Ali, Babar ;
Qureshi, Liaqat A. ;
Raza, Ali ;
Nawaz, Muhammad A. ;
Rehman, Safi U. ;
Rashid, Muhammad U. .
CIVIL ENGINEERING JOURNAL-TEHRAN, 2019, 5 (05) :1007-1019
[7]   Corrosion behavior of duplex stainless steel reinforcement in ternary binder concrete exposed to natural chloride penetration [J].
Alonso, M. C. ;
Luna, F. J. ;
Criado, M. .
CONSTRUCTION AND BUILDING MATERIALS, 2019, 199 :385-395
[8]  
American Concrete Institute (ACI), 2002, ACI 211.1-91
[9]   Use of Bagasse Ash in Concrete and Its Impact on the Strength and Chloride Resistivity [J].
Amin, Noor-ul .
JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2011, 23 (05) :717-720
[10]   Corrosion rate monitoring in the laboratory and on-site [J].
Andrade, C ;
Alonso, C .
CONSTRUCTION AND BUILDING MATERIALS, 1996, 10 (05) :315-328