Disposable cartridge biosensor platform for portable diagnostics

被引:0
作者
Yaras, Yusuf S. [1 ]
Cakmak, Onur [2 ]
Gunduz, Ali B. [1 ]
Saglam, Gokhan [1 ]
Olcer, Selim [1 ]
Mostafazadeh, Aref [1 ]
Baris, Ibrahim [1 ]
Civitci, Fehmi [3 ]
Yaralioglu, Goksen G. [4 ]
Urey, Hakan [1 ]
机构
[1] Koc Univ, TR-34450 Istanbul, Turkey
[2] Columbia Univ, New York, NY 10027 USA
[3] Istanbul Tech Univ, Ayazaga Campus, Istanbul, Turkey
[4] Ozyegin Univ, Orman St, TR-34794 Istanbul, Turkey
来源
OPTICS AND BIOPHOTONICS IN LOW-RESOURCE SETTINGS III | 2017年 / 10055卷
关键词
coagulation; biosensor; optical read out; MEMS; fiber sensor; aPTT; point of care;
D O I
10.1117/12.2254729
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We developed two types of cantilever-based biosensors for portable diagnostics applications. One sensor is based on MEMS cantilever chip mounted in a microfluidic channel and the other sensor is based on a movable optical fiber placed across a microfluidic channel. Both types of sensors were aimed at direct mechanical measurement of coagulation time in a disposable cartridge using plasma or whole blood samples. There are several similarities and also some important differences between the MEMS based and the optical fiber based solutions. The aim of this paper is to provide a comparison between the two solutions and the results. For both types of sensors, actuation of the cantilever or the moving fiber is achieved using an electro coil and the readout is optical. Since both the actuation and sensing are remote, no electrical connections are required for the cartridge. Therefore it is possible to build low cost disposable cartridges. The reader unit for the cartridge contains light sources, photodetectors, the electro coil, a heater, analog electronics, and a microprocessor. The reader unit has different optical interfaces for the cartridges that have MEMS cantilevers and moving fibers. MEMS based platform has better sensitivity but optomechanical alignment is a challenge and measurements with whole blood were not possible due to high scattering of light by the red blood cells. Fiber sensor based platform has relaxed optomechanical tolerances, ease of manufacturing, and it allows measurements in whole blood. Both sensors were tested using control plasma samples for activated-Partial-Thromboplastin-Time (aPTT) measurements. Control plasma test results matched with the manufacturer's datasheet. Optical fiber based system was tested for aPTT tests with human whole blood samples and the proposed platform provided repeatable test results making the system method of choice for portable diagnostics.
引用
收藏
页数:10
相关论文
共 50 条
[41]   A Disposable Alkaline Phosphatase-Based Biosensor for Vanadium Chronoamperometric Determination [J].
Lorena Alvarado-Gamez, Ana ;
Asuncion Alonso-Lomillo, Maria ;
Dominguez-Renedo, Olga ;
Julia Arcos-Martinez, Maria .
SENSORS, 2014, 14 (02) :3756-3767
[42]   An ITO Based Disposable Biosensor for Ultrasensitive Analysis of Retinol Binding Protein [J].
Simsek, Cigdem Sayikli ;
Teke, Mustafa ;
Sezginturk, Mustafa Kemal .
ELECTROANALYSIS, 2014, 26 (02) :328-339
[43]   Design of a toxicity biosensor based on Aliivibrio fischeri entrapped in a disposable card [J].
Sulivan Jouanneau ;
Marie-José Durand-Thouand ;
Gérald Thouand .
Environmental Science and Pollution Research, 2016, 23 :4340-4345
[44]   Technological conception of an optical biosensor with a disposable card for use with bioluminescent bacteria [J].
Horry, Habib ;
Charrier, Thomas ;
Durand, Marie-Jose ;
Vrignaud, Bernard ;
Picart, Pascal ;
Daniel, Philippe ;
Thouand, Gerald .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (02) :527-534
[45]   Design of a toxicity biosensor based on Aliivibrio fischeri entrapped in a disposable card [J].
Jouanneau, Sulivan ;
Durand-Thouand, Marie-Jose ;
Thouand, Gerald .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2016, 23 (05) :4340-4345
[46]   RPA using a multiplexed cartridge for low cost point of care diagnostics in the field [J].
Ereku, Luck Tosan ;
Mackay, Ruth E. ;
Craw, Pascal ;
Naveenathayalan, Angel ;
Stead, Thomas ;
Branavan, Manorharanehru ;
Balachandran, Wamadeva .
ANALYTICAL BIOCHEMISTRY, 2018, 547 :84-88
[47]   The Influencing Factors of Disposable Acetylcholinesterase Biosensor for in Situ Detection of Organophosphorus Pesticide [J].
Xiaowen Xu Xiaohao Wang Fei Tang Zhaoying Zhou State Key Laboratory of Precision Measurement Technology and InstrumentsTsinghua UniversityBeijing China .
稀有金属材料与工程, 2006, (S3) :389-391
[48]   Disposable amperometric biosensor for the determination of tyramine using plasma amino oxidase [J].
Ana Calvo-Pérez ;
Olga Domínguez-Renedo ;
María Asunción Alonso-Lomillo ;
María Julia Arcos-Martínez .
Microchimica Acta, 2013, 180 :253-259
[49]   The influencing factors of disposable acetylcholinesterase biosensor for in situ detection of organophosphorus pesticide [J].
Xu, Xiaowen ;
Wang, Xiaohao ;
Tang, Fei ;
Zhou, Zhaoying .
RARE METAL MATERIALS AND ENGINEERING, 2006, 35 :389-391
[50]   Disposable amperometric biosensor for the determination of tyramine using plasma amino oxidase [J].
Calvo-Perez, Ana ;
Dominguez-Renedo, Olga ;
Asuncion Alonso-Lomillo, Maria ;
Julia Arcos-Martinez, Maria .
MICROCHIMICA ACTA, 2013, 180 (3-4) :253-259