Absolute x-ray calibration of a gated x-ray framing camera for the Laser MegaJoule facility in the 0.1 keV-1 keV spectral range

被引:2
|
作者
Hubert, S. [1 ]
Boubault, F. [1 ]
机构
[1] CEA CESTA, F-33116 Le Barp, France
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2021年 / 92卷 / 03期
关键词
Plasma diagnostics - Laser diagnostics - Signal to noise ratio - Cameras;
D O I
10.1063/5.0004105
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
X-ray framing cameras (XRFCs) are routinely used at the Laser MegaJoule facility in x-ray imaging plasma diagnostics around the target chamber. Most of these diagnostics are based on multilayer x-ray toroidal mirrors under grazing incidence. The absolute calibration of the XRFCs is expressly expected both to optimize the signal-to-noise ratio for the dynamic range for specific experiments and to quantitatively process the data. The purpose of this paper is to describe our technique to routinely calibrate these instruments in the sub-keV spectral range. The calibration presented in this work was carried out using the XRFC enclosed in a sealed "airbox" structure. This calibration relies on a Manson source recently upgraded to operate at high emission current (5 mA) with 10 kV accelerating voltage to work with a 1-m grazing-incidence Rowland circle monochromator. The framing camera sensitivity was absolutely determined over the 0.1-1.2 spectral range with an average uncertainty of 2.4% rms while operating in DC mode. Finally, we compare the results with a synchrotron source calibration previously obtained and a theoretical model.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] A new double crystal calibration system for absolute x-ray emission measurements down to ∼1 keV energies
    Hobbs, L. M. R.
    Brant, S.
    Brent, K.
    Hoarty, D.
    Bentley, C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (03):
  • [42] Fabrication and absolute calibration of X-ray streak camera cathode
    Li, Jin
    Hu, Xin
    Fan, Long
    Chen, Tao
    Yang, Zhiwen
    Deng, Bo
    Li, Yukun
    Cao, Zhurong
    Liu, Shenye
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2015, 27 (08):
  • [43] ABSOLUTE SPECTRAL SENSITIVITY OF LINEAR-PHOTODIODE ARRAYS IN 7-20 KEV ENERGY X-RAY RANGE
    DOLBNYA, IP
    KURYLO, SG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 677 - 679
  • [44] Proximity-gated X-ray framing camera with gain uniformity
    Fu, W.
    Long, J.
    Cai, H.
    Liu, J.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (06)
  • [45] EFFICIENCY CALIBRATION OF SEMICONDUCTOR X-RAY DETECTORS IN ENERGY RANGE 3-200 KEV
    CAMPBELL, JL
    MCNELLES, LA
    NUCLEAR INSTRUMENTS & METHODS, 1972, 101 (01): : 153 - &
  • [46] ABSOLUTE CALIBRATION OF X-RAY-FILMS OF THE SPACED X-RAY EMULSION CAMERA METHOD
    AKHMETOV, AK
    IZVESTIYA AKADEMII NAUK SSSR SERIYA FIZICHESKAYA, 1982, 46 (09): : 1797 - 1798
  • [47] X-ray spectroscopy and calibrations in the 50 eV to 60 keV range
    Seely, JF
    Hudson, LT
    Weaver, JL
    Holland, GE
    Boyer, CN
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS IV, 2002, 4786 : 183 - 188
  • [48] SOLAR X-RAY SPECTRA IN 2-20 KEV RANGE
    CHUBB, TA
    KREPLIN, RW
    FRIEDMAN, H
    ASTRONOMICAL JOURNAL, 1963, 68 (05): : 276 - &
  • [49] X-ray spectroscopy and calibrations in the 50 eV to 60 keV range
    Seely, J
    Feldman, U
    Weaver, J
    Hudson, L
    ADVANCED DIAGNOSTICS FOR MAGNETIC AND INERTIAL FUSION, 2002, : 245 - 248
  • [50] VERSATILE X-RAY SPECTROMETER IN RANGE 5-200 KEV
    STRACHAN, JD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1976, 47 (12): : 1542 - 1546