Design and testing of aptamer-based electrochemical biosensors for proteins and small molecules

被引:126
|
作者
Cheng, Alan K. H. [1 ]
Sen, Dipankar [1 ,2 ]
Yu, Hua-Zhong [1 ,2 ]
机构
[1] Simon Fraser Univ, Dept Chem, Burnaby, BC V5A 1S6, Canada
[2] Simon Fraser Univ, Dept Mol Biol & Biochem, Burnaby, BC V5A 1S6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Aptamer; Biosensor; Electrochemistry; Protein; DNA/RNA; DNA-MODIFIED SURFACES; LABEL-FREE; ELECTRON-TRANSFER; NUCLEIC-ACID; CATIONIC POLYTHIOPHENE; SENSITIVE DETECTION; SENSORS; RECOGNITION; BINDING; QUANTITATION;
D O I
10.1016/j.bioelechem.2009.04.007
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The fabrication of aptamer-based electrochemical biosensors as an emerging technology has made the detection of small and macromolecular analytes easier, faster, and more suited for the ongoing transition from fundamental analytical science to the early detection of protein biomarkers. Aptamers are synthetic oligonucleotides that have undergone iterative rounds of in vitro selection for binding with high affinity to specific analytes of choice; a sensitive yet simple method to utilize aptamers as recognition entities for the development of biosensors is to transduce the signal electrochemically. In this review article, we attempt to summarize the state-of-the-art research progresses that have been published in recent years; in particular, we focus on the electrochemical biosensors that incorporate aptamers for sensing small organic molecules and proteins. Based on differences in the design of the DNA/RNA-modified electrodes, we classify aptamer-based electrochemical sensors into three categories, for which the analyte detection relies on: (a) configurational change, i.e.. the analyte binding induces either an assembly or dissociation of the sensor construct: (b) conformational change. i.e., the analyte binding induces an alteration in the conformation (folding) of the surface immobilized aptamer strands: and (c) conductivity change, i.e., the analyte binding "switches on" the conductivity of the surface-bound aptamer-DNA constructs. In each section, we will discuss the performance of these novel biosensors with representative examples reported in recent literature. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 50 条
  • [31] Label-free electrochemical monitoring of vasopressin in aptamer-based microfluidic biosensors
    He, Peng
    Oncescu, Vlad
    Lee, Seoho
    Choi, Inhee
    Erickson, David
    ANALYTICA CHIMICA ACTA, 2013, 759 : 74 - 80
  • [32] Evaluation of Transducer Elements Based on Different Material Configurations for Aptamer-Based Electrochemical Biosensors
    Carrasco, Ivan Lopez
    Cuniberti, Gianaurelio
    Opitz, Joerg
    Beshchasna, Natalia
    BIOSENSORS-BASEL, 2024, 14 (07):
  • [33] Aptamer-based sandwich-type biosensors
    Bin Seo, Ho
    Gu, Man Bock
    JOURNAL OF BIOLOGICAL ENGINEERING, 2017, 11
  • [34] Recent Advances in Aptamer-Based Biosensors for Detection of Pseudomonas aeruginosa
    Zheng, Xin
    Gao, Shunxiang
    Wu, Jihong
    Hu, Xiaobo
    FRONTIERS IN MICROBIOLOGY, 2020, 11
  • [35] Nucleic acid aptamer-based biosensors and their application in thrombin analysis
    Dong, Hang
    Liu, Xiyu
    Gan, Lu
    Fan, Dianfa
    Sun, Xinjun
    Zhang, Zhikun
    Wu, Pan
    BIOANALYSIS, 2023, 15 (09) : 513 - 532
  • [36] Aptamer-based biosensors for virus protein detection
    Lou, Beibei
    Liu, Yanfei
    Shi, Meilin
    Chen, Jun
    Li, Ke
    Tan, Yifu
    Chen, Liwei
    Wu, Yuwei
    Wang, Ting
    Liu, Xiaoqin
    Jiang, Ting
    Peng, Dongming
    Liu, Zhenbao
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 157
  • [37] Aptamer-Based Biosensors for Antibiotic Detection: A Review
    Mehlhorn, Asol
    Rahimi, Parvaneh
    Joseph, Yvonne
    BIOSENSORS-BASEL, 2018, 8 (02):
  • [38] Aptamer-based lateral flow assay on-site biosensors
    Huang, Lei
    Tian, Shulin
    Zhao, Wenhao
    Liu, Ke
    Ma, Xing
    Guo, Jinhong
    BIOSENSORS & BIOELECTRONICS, 2021, 186
  • [39] Aptamer-based 'point-of-care testing'
    Gopinath, Subash C. B.
    Lakshmipriya, Thangavel
    Chen, Yeng
    Phang, Wai-Mei
    Hashim, Uda
    BIOTECHNOLOGY ADVANCES, 2016, 34 (03) : 198 - 208
  • [40] Advances in Electrochemical and Acoustic Aptamer-Based Biosensors and Immunosensors in Diagnostics of Leukemia
    Hianik, Tibor
    BIOSENSORS-BASEL, 2021, 11 (06):