Remote processing server for ECG-based clinical diagnosis support

被引:19
作者
García, J
Martínez, I
Sörnmo, L
Olmos, S
Mur, A
Laguna, P
机构
[1] Univ Zaragoza, Dept Elect Engn & Commun, Commun Technol Grp, Zaragoza 500015, Spain
[2] Lund Univ, Dept Appl Elect, Signal Proc Grp, S-22100 Lund, Sweden
来源
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE | 2002年 / 6卷 / 04期
关键词
electrocardiographic (ECG); graphical user interface; remote diagnosis; signal processing; telemedicine;
D O I
10.1109/TITB.2002.806087
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, we present the development of a remote server that provides a user-friendly access to advanced electrocardiographic (ECG) signal processing techniques. The prototype supplies telemedicine facilities to doctors for clinical indexes remote computation to support diagnosis through the Internet. The user-friendly interface is based on the selection of the desired ECG signal processing tools on a Web browser window. The centralized structure of the system permits unique and user-independent update and management of the software and, therefore, is especially suitable for remote or rural regions to have access to the new ECG information techniques.
引用
收藏
页码:277 / 284
页数:8
相关论文
共 25 条
[1]  
[Anonymous], 1992, DISCRETE RANDOM SIGN
[2]   Maximum likelihood analysis of cardiac late potentials [J].
Atarius, R ;
Sornmo, L .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (01) :60-68
[3]   A portable ECG and blood pressure telemonitoring system [J].
Bai, J ;
Zhang, YH ;
Shen, DL ;
Wen, LF ;
Ding, CX ;
Cui, ZJ ;
Tian, FH ;
Yu, B ;
Dai, B ;
Zhang, JP .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1999, 18 (04) :63-70
[4]  
Bronzino J.D., 1995, The Biomedical Engineering Handbook
[5]   Automatic detection of ST-T complex changes on the ECG using filtered RMS difference series:: Application to ambulatory ischemia monitoring [J].
García, J ;
Sörnmo, L ;
Olmos, S ;
Laguna, P .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (09) :1195-1201
[6]   Identification of the occluded artery in patients with myocardial ischemia induced by prolonged percutaneous transluminal coronary angioplasty using traditional vs transformed ECG-based indexes [J].
García, J ;
Wagner, G ;
Sörnmo, L ;
Lander, P ;
Laguna, P .
COMPUTERS AND BIOMEDICAL RESEARCH, 1999, 32 (05) :470-482
[7]   Temporal evolution of traditional versus transformed EGG-based indexes in patients with induced myocardial ischemia [J].
García, J ;
Wagner, G ;
Sörnmo, L ;
Olmos, S ;
Lander, P ;
Laguna, P .
JOURNAL OF ELECTROCARDIOLOGY, 2000, 33 (01) :37-47
[8]   Transmission of electrocardiograms from a moving ambulance [J].
Giovas, P ;
Papadoyannis, D ;
Thomakos, D ;
Papazachos, G ;
Soulis, D ;
Stamatopoulos, C ;
Mavrogeni, S ;
Katsilambros, M .
JOURNAL OF TELEMEDICINE AND TELECARE, 1998, 4 :5-7
[9]  
Holle R, 1999, IEEE Trans Inf Technol Biomed, V3, P84, DOI 10.1109/4233.767083
[10]  
Horsch A, 1999, IEEE Trans Inf Technol Biomed, V3, P166, DOI 10.1109/4233.788578