Image quality and dose assessment of collimator slit width effect in SLOT-SCAN X-ray imaging system

被引:7
作者
Hossein, Mohammadi [1 ]
Reza, Shojaei Mohammad [1 ]
Jamshid, Soltani-Nabipour [2 ]
机构
[1] Shahrood Univ Technol, Dept Phys, Shahrood, Iran
[2] Islamic Azad Univ, Parand Branch, Fac Comp & IT, Dept Phys, Parand, Iran
关键词
Slot-scan imaging system; Gate simulation; DQE; Image quality; DIGITAL RADIOGRAPHY; MAMMOGRAPHY; SIMULATION; SELENIUM; NOISE; MTF;
D O I
10.1016/j.apradiso.2021.109642
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The effect of collimator slit width on patient absorbed dose and image quality is evaluated in the SLOT-SCAN imaging system. For this purpose, GATE Monte-Carlo code was used for simulation. To determine contrast to noise ratio (CNR), copper filters with different thicknesses were used and a 2mm lead filter was applied for the determination of the Modulation Transfer Function (MTF) and Detective Quantum Efficiency (DQE). Spatial resolution was determined by using line-pairs per millimeter test. In addition, the anthropomorphic digital Zubal phantom was used to estimate the patient absorbed dose. As the results showed, the CNR shows 77% reduction by decreasing the collimator slit width from 4 mm to 0.4 mm. Other parameters such as DQE and spatial resolution showed to be constant. Finally, whole-body patient absorbed dose estimation resulted in reduction of 14 times using the 0.4 mm collimator slit. The results showed that decreasing the slit width reduced the patient absorbed dose without any significant change in the image quality.
引用
收藏
页数:7
相关论文
共 31 条
  • [1] [Anonymous], 2008, IEC 62220 1
  • [2] Balasubramaniam K, 2009, P NAT SEM EXH NONDES
  • [3] Quality control assessment of Philips digital radiography and comparison with Spellman and Samsung systems in Tehran Oil Ministry Hospital
    Banihashemi, Navid
    Soltani-Nabipour, Jamshid
    Khorshidi, Abdollah
    Mohammadi, Hossein
    [J]. EUROPEAN PHYSICAL JOURNAL PLUS, 2020, 135 (02)
  • [4] Evaluating imaging systems: practical applications
    Bath, Magnus
    [J]. RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 26 - 36
  • [5] Scatter/primary in mammography: Comprehensive results
    Boone, JM
    Lindfors, KK
    Cooper, VN
    Seibert, JA
    [J]. MEDICAL PHYSICS, 2000, 27 (10) : 2408 - 2416
  • [6] De Villiers M., 2003, P SPIE MED IMAGING, V5030
  • [7] De Villiers M., 2003, PROC SPIE, V5030
  • [8] Mammography Images Restoration by Quantum Noise Reduction and Inverse MTF Filtering
    dos Santos Romualdo, Larissa Cristina
    da Costa Vieira, Marcelo Andrade
    Schiabel, Homero
    [J]. 2009 XXII BRAZILIAN SYMPOSIUM ON COMPUTER GRAPHICS AND IMAGE PROCESSING (SIBGRAPI 2009), 2009, : 180 - 185
  • [9] Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems
    Flynn, MJ
    Samei, E
    [J]. MEDICAL PHYSICS, 1999, 26 (08) : 1612 - 1623
  • [10] Accuracy validation of incident photon fluence on DQE for various measurement conditions and X-ray units
    Haba T.
    Kondo S.
    Hayashi D.
    Koyama S.
    [J]. Radiological Physics and Technology, 2013, 6 (2) : 423 - 430