Safety risk modeling and major accidents analysis of hydrogen and natural gas releases: A comprehensive risk analysis framework

被引:93
作者
Mohammadfam, Iraj [1 ,2 ]
Zarei, Esmaeil [1 ,2 ,3 ]
机构
[1] Hamadan Univ Med Sci, Sch Publ Hlth, Dept Occupat Hlth Engn, Hamadan, Iran
[2] Hamadan Univ Med Sci, Res Ctr Hlth Sci, Hamadan, Iran
[3] Hamadan Univ Med Sci, Student Res Ctr, Hamadan, Iran
关键词
Risk modeling; Risk assessment; QRA; Hydrogen safety; Consequence; HAZOP; FUELING STATIONS;
D O I
10.1016/j.ijhydene.2015.07.117
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The potential safety risk of hydrogen production is often the most important element to achieve authority approval and public acceptance. Safe application of hydrogen, especially in a large scale, will require adopting adequate risk control, which requires investment on reliable risk analysis methodology. In the present study, first of all, a reliable and comprehensive safety risk analysis methodology was developed for a hydrogen production plant in an oil refinery, that consists of two qualitative methods: Hazard and Operability (HAZOP) and Preliminary Risk Analysis (PRA), a hybrid method: Event Tree Analysis (ETA) and a quantitative method: Quantitative Risk Assessment (QRA) along with a risk and consequence simulator. A HAZOP study along with the PRA technique was used for determining main hazardous sources and carrying out a qualitative risk analysis. The incident outcomes of the identified high risk scenarios were modeled using the PHAST 6.7 simulator and the frequencies of the initial events and incident outcomes were calculated using risk assessment data directory of International Association Oil & Gas Producers (OGP) and ETA, respectively. Finally, the vulnerability areas of the incident outcomes were determined and the societal risk of hydrogen plant was shown using a 'Frequency vs. Number of fatality' graph, known as 'F-N' curves. The findings show that the maximum vulnerability distance is caused by the vapor cloud explosion (280 m, at 0.01 bar) and the jet fire (275 m, at 4 kW/m(2)), respectively. The societal risk of the plant fell in the As Low As Reasonable Practical (ALARP) and intolerable regions according to the F-N curve of UK HSE (Health, Safety Executive) The reformer were the highest and the heat exchanger was the lowest contributor to the total risk. Therefore, the ALARP principle should be applied to indicate the appropriate ways to reduce risks and, for the intolerable risks, the system must be modified structurally, functionally, or organizationally. Copyright (C) 2015, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:13653 / 13663
页数:11
相关论文
共 40 条
[1]   Accident modelling and safety measure design of a hydrogen station [J].
Al-shanini, A. ;
Ahmad, A. ;
Khan, F. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (35) :20362-20370
[2]  
[Anonymous], 2006, INFORM TECHNOLOGY J
[3]  
Badri N, 2011, IRAN J CHEM CHEM ENG, V30, P113
[4]  
CCPS (Center for Chemical Process Safety), 2000, GUID CHEM PROC QUANT
[5]  
Det Norske Veritas, 2008, CT1910 DNV
[6]   Quantitative risk assessment integrated with process simulator for a new technology of methanol production plant using recycled CO2 [J].
Di Domenico, Julia ;
Vaz, Carlos Andre, Jr. ;
de Souza, Mauricio Bezerra, Jr. .
JOURNAL OF HAZARDOUS MATERIALS, 2014, 274 :164-172
[7]   Risk analysis by means of a QRA approach on a LPG cylinder filling installation [J].
Dormohammadi, Ali ;
Zarei, Esmaeil ;
Delkhosh, Mohammad Bagher ;
Gholami, Ali .
PROCESS SAFETY PROGRESS, 2014, 33 (01) :77-84
[8]  
Eisenberg N.A., 1975, VULNERABILITY MODEL
[9]   SAFETY BEHAVIORS ASSESSMENT IN PROCESS INDUSTRY: A CASE STUDY IN GAS REFINERY [J].
Fam, I. Mohammad ;
Azadeh, A. ;
Faridan, M. ;
Mahjub, H. .
JOURNAL OF INDUSTRIAL AND PRODUCTION ENGINEERING, 2008, 25 (04) :298-305
[10]  
Fotis Rigas, 2012, HYDROGEN SAFETY GREE