Quality of reporting of randomized controlled trials published in Intensive Care Medicine from 2001 to 2010

被引:38
作者
Latronico, Nicola [1 ,2 ]
Metelli, Marta [1 ]
Turin, Maddalena [1 ]
Piva, Simone [2 ]
Rasulo, Frank A. [2 ]
Minelli, Cosetta [3 ]
机构
[1] Univ Brescia, Spedali Civili, Dept Anesthesia Crit Care & Perioperat Med, Univ Div Anesthesia & Crit Care Med, I-25123 Brescia, Italy
[2] Univ Brescia, Spedali Civili, Dept Anesthesia Intens Care & Perioperat Med, Univ Div Neuroanesthesia & Neurocrit Care, I-25123 Brescia, Italy
[3] Univ London Imperial Coll Sci Technol & Med, Natl Heart & Lung Inst, Resp Epidemiol & Publ Hlth Grp, London, England
关键词
Methodology; Quality of reporting; Randomization; Impact factor; Google scholar; Scopus; Web of Science; CLINICAL-TRIALS; EMPIRICAL-EVIDENCE; BIAS; JOURNALS; MULTIPLICITY; OUTCOMES; REVIEWS;
D O I
10.1007/s00134-013-2947-3
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To evaluate the methodological quality of randomized controlled trials (RCTs) published in Intensive Care Medicine from 2001 to 2010, and to compare it with a previous review of RCTs published from 1975 to 2000. We assessed the quality of reporting of randomization, blinding and participant flow, both individually and combined within the Jadad scale, and compared them with findings from our previous review. For RCTs published from 2001 to 2010, we also evaluated the frequency of distorted finding presentation (spin) and inflated predicted treatment effect (delta inflation). In the 221 RCTs from 2001 to 2010, the sample size was significantly larger than in the older series, and there was a higher proportion of studies with negative findings. Reporting of the rationale for sample size estimation and allocation concealment increased significantly, but reporting of other important individual methodological components did not change substantially compared with the previous period and remained low. Among RCTs from 2001 to 2010, a spin strategy was used in 69 of 111 RCTs with statistically negative results, while delta inflation was present in 7 of 11 RCTs evaluating survival as a primary outcome. Papers with higher Jadad scores were cited more often than the others. Quality of reporting of RCTs published in Intensive Care Medicine has only partly improved over time, and spin and delta bias are of frequent occurrence. There is a need for stronger adherence to CONSORT recommendations, with special emphasis on accurate description of randomization and blindness, and correct reporting of statistically non-significant results.
引用
收藏
页码:1386 / 1395
页数:10
相关论文
共 57 条
  • [1] Delta inflation: A bias in the design of randomized controlled trials in critical care medicine
    Aberegg S.K.
    Richards D.R.
    O'Brien J.M.
    [J]. Critical Care, 14 (2):
  • [2] Agha RA, 2012, J PLAST RECONSTR AES
  • [3] STATISTICS NOTES - ABSENCE OF EVIDENCE IS NOT EVIDENCE OF ABSENCE
    ALTMAN, DG
    BLAND, JM
    [J]. BRITISH MEDICAL JOURNAL, 1995, 311 (7003) : 485 - 485
  • [4] Systematic reviews in health care - Systematic reviews of evaluations of prognostic variables
    Altman, DG
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2001, 323 (7306): : 224 - 228
  • [5] The revised CONSORT statement for reporting randomized trials: Explanation and elaboration
    Altman, DG
    Schulz, KF
    Moher, D
    Egger, M
    Davidoff, F
    Elbourne, D
    Gotzsche, PC
    Lang, T
    [J]. ANNALS OF INTERNAL MEDICINE, 2001, 134 (08) : 663 - 694
  • [6] In praise of soft science
    不详
    [J]. NATURE, 2005, 435 (7045) : 1003 - 1003
  • [7] [Anonymous], ANN INTERN MED
  • [8] The identity of Intensive Care Medicine
    Azoulay, Elie
    Citerio, Giuseppe
    Timsit, Jean-Francois
    [J]. INTENSIVE CARE MEDICINE, 2013, 39 (03) : 343 - 344
  • [9] Methodological Reporting of Randomized Clinical Trials in Major Gastroenterology and Hepatology Journals in 2006
    Bai, Yu
    Gao, Jun
    Zou, Duo-Wu
    Li, Zhao-Shen
    [J]. HEPATOLOGY, 2009, 49 (06) : 2108 - 2112
  • [10] Morgagni and the impact factor
    Bonati, MR
    Drusini, AG
    [J]. NATURE, 1996, 381 (6580) : 271 - 271