Automated Fiducial Localization in CT Images Based on Surface Processing and Geometrical Prior Knowledge for Radiotherapy Applications

被引:20
作者
Fattori, Giovanni [1 ]
Riboldi, Marco [1 ,2 ]
Desplanques, Maxime [2 ]
Tagaste, Barbara [2 ]
Pella, Andrea [1 ]
Orecchia, Roberto [2 ,3 ,4 ]
Baroni, Guido [1 ,2 ]
机构
[1] Politecn Milan, Dept Bioengn, I-20133 Milan, Italy
[2] Ctr Nazl Adroterapia Oncol Fdn, I-27100 Pavia, Italy
[3] European Inst Oncol, I-435 Milan, Italy
[4] Univ Milan, Dept Sci & Biomed Technol, I-20122 Milan, Italy
关键词
Automated detection; CT scanning; fiducial localization; particle therapy; patient positioning; radiotherapy; TRACKING SYSTEM; TUMOR TRACKING; REGISTRATION; MARKERS; ERROR; ACCURACY;
D O I
10.1109/TBME.2012.2198822
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We propose a novelmethod for radio-opaque external marker localization in CT scans for infrared (IR) patient set-up in radiotherapy. Efforts were focused on the quantification of uncertainties in marker localization in the CT dataset as a function of algorithm performance. We implemented a 3-D approach to fiducial localization based on surface extraction and marker recognition according to geometrical prior knowledge. The algorithm parameters were optimized on a clinical CT dataset coming from 35 cranial and extra-cranial patients; the localization accuracy was benchmarked at variable image resolution versus laser tracker measurements. The applicability of conventional IR optical tracking systems for localizing external surrogates in daily patient set-up procedures was also investigated in 121 proton therapy treatment sessions. Our study shows that the implemented algorithm features surrogates localization with uncertainties lower than 0.3 mm and with a true positive rate of 90.1%, being this latter mainly influenced by fiducial homogeneity in the CT images. The reported clinical validation in proton therapy confirmed the submillimetric accuracy and the expected algorithm sensitivity. Geometrical prior knowledge allows judging the reliability of the extracted fiducial coordinates, ensuring the highest accuracy in patient set-up.
引用
收藏
页码:2191 / 2199
页数:9
相关论文
共 40 条
[1]   Mesh: Measuring errors between surfaces using the Hausdorff distance [J].
Aspert, N ;
Santa-Cruz, D ;
Ebrahimi, T .
IEEE INTERNATIONAL CONFERENCE ON MULTIMEDIA AND EXPO, VOL I AND II, PROCEEDINGS, 2002, :705-708
[2]   The safety and efficacy of robotic image-guided radiosurgery system treatment for intra- and extracranial lesions: A systematic review of the literature [J].
Calcerrada Diaz-Santos, Nieves ;
Blasco Amaro, Juan Antonio ;
Ariza Cardiel, Gloria ;
Andradas Aragones, Elena .
RADIOTHERAPY AND ONCOLOGY, 2008, 89 (03) :245-253
[3]  
Capek M., 2001, P 9 INT C CENTR EUR
[4]  
Chen DG, 2006, INT J COMPUT ASS RAD, V1, P45
[5]   Image-guided radiotherapy: rationale, benefits, and limitations [J].
Dawson, Laura A. ;
Sharpe, Michael B. .
LANCET ONCOLOGY, 2006, 7 (10) :848-858
[6]   Skin respiratory motion tracking for stereotactic radiosurgery using the CyberKnife [J].
Dieterich, S ;
Tang, J ;
Rodgers, J ;
Cleary, K .
CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 :130-136
[7]  
Engelsman M., 2005, MED PHYS, V32
[8]   Predicting error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB ;
Maurer, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :694-702
[9]   Derivation of expected registration error for point-based rigid-body registration [J].
Fitzpatrick, JM ;
West, JB ;
Maurer, CR .
MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 :16-27
[10]  
Gu LX, 2004, LECT NOTES COMPUT SC, V3150, P329