Microplasma source for optogalvanic spectroscopy of nanogram samples

被引:15
作者
Berglund, M. [1 ]
Thornell, G. [1 ]
Persson, A. [1 ,2 ]
机构
[1] Uppsala Univ, Dept Engn Sci, Angstrom Space Technol Ctr, SE-75121 Uppsala, Sweden
[2] Uppsala Univ, Dept Phys & Astron, SE-75120 Uppsala, Sweden
关键词
1/F NOISE; RADIOCARBON; MODEL; C-14;
D O I
10.1063/1.4813414
中图分类号
O59 [应用物理学];
学科分类号
摘要
The demand for analysis of smaller samples in isotopic ratio measurements of rare isotopes is continuously rising with the development of new applications, particularly in biomedicine. Interesting in this aspect are methods based on optogalvanic spectroscopy, which have been reported to facilitate both C-13-to-C-12 and C-14-to-C-12 ratio measurements with high sensitivity. These methods also facilitate analysis of very small samples, down to the microgram range, which makes them very competitive to other technologies, e. g., accelerator mass spectroscopy. However, there exists a demand for moving beyond the microgram range, especially from regenerative medicine, where samples consist of, e.g., DNA, and, hence, the total sample amount is extremely small. Making optogalvanic spectroscopy of carbon isotopes applicable to such small samples, requires miniaturization of the key component of the system, namely the plasma source, in which the sample is ionized before analysis. In this paper, a novel design of such a microplasma source based on a stripline split-ring resonator is presented and evaluated in a basic optogalvanic spectrometer. The investigations focus on the capability of the plasma source to measure the optogalvanic signal in general, and the effect of different system and device specific parameters on the amplitude and stability of the optogalvanic signal in particular. Different sources of noise and instabilities are identified, and methods of mitigating these issues are discussed. Finally, the ability of the cell to handle analysis of samples down to the nanogram range is investigated, pinpointing the great prospects of stripline split-ring resonators in optogalvanic spectroscopy. (C) 2013 AIP Publishing LLC.
引用
收藏
页数:11
相关论文
共 28 条
[1]  
Berglund M., PLASMA SOURCES UNPUB
[2]   Atomic weights of the elements:: Review 2000 -: (IUPAC technical report) [J].
De Laeter, JR ;
Böhlke, JK ;
De Bièvre, P ;
Hidaka, H ;
Peiser, HS ;
Rosman, KJR ;
Taylor, PDP .
PURE AND APPLIED CHEMISTRY, 2003, 75 (06) :683-800
[3]   THE RADIOCARBON INTRACAVITY OPTOGALVANIC SPECTROSCOPY SETUP AT UPPSALA [J].
Eilers, Gerriet ;
Persson, Anders ;
Gustavsson, Cecilia ;
Ryderfors, Linus ;
Mukhtar, Emad ;
Possnert, Goran ;
Salehpour, Mehran .
RADIOCARBON, 2013, 55 (2-3) :237-250
[4]   NATURAL I-129 AS AN ENVIRONMENTAL TRACER [J].
FABRYKAMARTIN, J ;
BENTLEY, H ;
ELMORE, D ;
AIREY, PL .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1985, 49 (02) :337-347
[5]   Molecular Gas Sensing Below Parts Per Trillion: Radiocarbon-Dioxide Optical Detection [J].
Galli, I. ;
Bartalini, S. ;
Borri, S. ;
Cancio, P. ;
Mazzotti, D. ;
De Natale, P. ;
Giusfredi, G. .
PHYSICAL REVIEW LETTERS, 2011, 107 (27)
[6]   OPTOGALVANIC SPECTROSCOPY [J].
GOLDSMITH, JEM ;
LAWLER, JE .
CONTEMPORARY PHYSICS, 1981, 22 (02) :235-248
[7]   1/F NOISE IS NO SURFACE EFFECT [J].
HOOGE, FN .
PHYSICS LETTERS A, 1969, A 29 (03) :139-&
[8]  
Ilkmen E., 2009, THESIS RUTGERS NEWAR
[9]   Split-ring resonator microplasma: microwave model, plasma impedance and power efficiency [J].
Iza, F ;
Hopwood, J .
PLASMA SOURCES SCIENCE & TECHNOLOGY, 2005, 14 (02) :397-406
[10]   Accelerator Mass Spectrometry Targets of Submilligram Carbonaceous Samples Using the High-Throughput Zn Reduction Method [J].
Kim, Seung-Hyun ;
Kelly, Peter B. ;
Clifford, Andrew J. .
ANALYTICAL CHEMISTRY, 2009, 81 (14) :5949-5954