BRDF STUDY OF GRAY-SCALE SPECTRALON

被引:17
|
作者
Georgiev, Georgi T. [1 ]
Butler, James J. [2 ]
机构
[1] Sci Syst & Applicat Inc, Lanham, MD 20706 USA
[2] NASA, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA
来源
EARTH OBSERVING SYSTEMS XIII | 2008年 / 7081卷
关键词
BRDF; Spectralon; Metrology; Reflectance; Optical Instruments; Remote Sensing;
D O I
10.1117/12.795931
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Satellite instruments operating in the reflective solar wavelength region often require accurate and precise determination of the Bidirectional Reflectance Distribution Function (BRDF) of laboratory based diffusers used in their pre-flight calibrations. In this paper we present gray Spectralon BRDF measured using a monochromatic broadband source at ultraviolet, visible and near-infrared wavelengths. By comparing these results, we quantitatively examine the wavelength and geometrical scatter properties of gray-scale Spectralon. The Spectralon diffusers with specified hemispherical reflectances of 2%, 5%, 10%, 20%, 30%, 40%, 50%, 60%, 70%, 80%, and 99% were measured using P and S incident polarized light over a range of incident and scatter angles. The measurements are compared, and the influence of material composition on the BRDF is described. The future application of gray-scale Spectralon in the calibration of spaceborne sensors is described. All data were obtained using the out-of-plane scatterometer located in NASA's Goddard Space Flight Center's Diffuser Calibration Facility. The results are NIST traceable.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] GRAY-SCALE ALIAS
    BOCK, P
    KLINNERT, R
    KOBER, R
    ROVNER, RM
    SCHMIDT, H
    IEEE TRANSACTIONS ON KNOWLEDGE AND DATA ENGINEERING, 1992, 4 (02) : 109 - 122
  • [2] GRAY-SCALE HOUGH TRANSFORM FOR THICK LINE DETECTION IN GRAY-SCALE IMAGES
    LOT, RC
    TSAI, WH
    PATTERN RECOGNITION, 1995, 28 (05) : 647 - 661
  • [3] GRAY-SCALE ULTRASONOGRAPHY AND JAUNDICE
    SURAMO, I
    HYVARINEN, S
    KAIRALUOMA, M
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1980, 15 (06) : 705 - 709
  • [4] Gray-scale atom holography
    Kishimoto, T
    Fujita, J
    Mitake, S
    Shimizu, F
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1999, 38 (6AB): : L683 - L686
  • [5] GRAY-SCALE ULTRASONOGRAPHY OF THYROID
    CHILCOTE, WS
    RADIOLOGY, 1976, 120 (02) : 381 - 383
  • [6] GRAY-SCALE PLASMA DISPLAY
    NGO, DT
    SID INTERNATIONAL SYMPOSIUM DIGEST OF TECHNICAL PAPERS, 1971, 11 (MAY): : 100 - &
  • [7] Reconstruction of Gray-Scale Images
    Pablo A. Ferrari
    Marco D. Gubitoso
    E. Jordão Neves
    Methodology And Computing In Applied Probability, 2001, 3 (3) : 255 - 270
  • [8] GRAY-SCALE ULTRASONOGRAPHY OF THE NECK
    GOODING, GAW
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1980, 243 (15): : 1562 - 1564
  • [9] GRAY-SCALE SONOGRAPHY AND IUD
    VANEYCK, J
    DEFOORT, P
    THIERY, M
    CONTRACEPTION, 1976, 13 (04) : 489 - 496
  • [10] Technique of gray-scale mask
    Li, Hongjun
    Li, Fengyou
    Yu, Limin
    Cao, Yingjing
    Lu, Zhenwu
    Liao, Jianghong
    Weng, Zhicheng
    Weixi Jiagong Jishu/Microfabrication Technology, 2000, (01): : 10 - 15