2-D army for 3-D ultrasound imaging using synthetic aperture techniques

被引:49
作者
Daher, NM [1 ]
Yen, JT [1 ]
机构
[1] Univ So Calif, Dept Biomed Engn, Los Angeles, CA 90089 USA
关键词
D O I
10.1109/TUFFC.2006.1632682
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A two-dimensional (2-D) array of 256 X 256 = 65, 536 elements, with total area 4 X 4 = 16 cm(2), serves as a flexible platform for developing acquisition schemes for 3-D rectilinear ultrasound imaging at 10 MHz using synthetic aperture techniques. This innovative system combines a simplified interconnect scheme and synthetic aperture techniques with a 2-D array for 3-D imaging. A row-column addressing scheme is used to access different elements for different transmit events. This addressing scheme is achieved through a simple interconnect, consisting of one top, one bottom single-layer, flex circuits that, compared to multilayer flex circuits, are simpler to design, cheaper to manufacture, and thinner so their effect on the acoustic response is minimized. We present three designs that prioritize different design objectives: volume acquisiton time, resolution, and sensitivity, while maintaining acceptable figures for the other design objectives. For example, one design overlooks time-acquisition requirements, assumes good noise conditions, and optimizes for resolution, achieving -6 dB and -20 dB beamwidths of less than 0.2 and 0.5 nun, respectively, for an F/2 aperture. Another design can acquire an entire volume in 256 transmit events, with -6 dB and -20 dB beamwidths in the order of 0.4 and 0.8 rum, respectively.
引用
收藏
页码:912 / 924
页数:13
相关论文
共 22 条
[1]  
ALAIS P, 1991, ACOUST IMAGING, V18, P431
[2]   3D ultrasound imaging: applications in image-guided therapy and biopsy [J].
Fenster, A ;
Surry, K ;
Smith, W ;
Gill, J ;
Downey, DB .
COMPUTERS & GRAPHICS-UK, 2002, 26 (04) :557-568
[3]   3-D ultrasound imaging: A review [J].
Fenster, A ;
Downey, DB .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (06) :41-51
[4]   Synthetic elevation beamforming and image acquisition capabilities using an 8 x 128 1.75D array [J].
Fernandez, AT ;
Gammelmark, KL ;
Dahl, JJ ;
Keen, CG ;
Gauss, RC ;
Trahey, GE .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (01) :40-57
[5]  
Gauss RC, 1999, ULTRASON, P1563, DOI 10.1109/ULTSYM.1999.849294
[6]   CALCULATION OF PRESSURE FIELDS FROM ARBITRARILY SHAPED, APODIZED, AND EXCITED ULTRASOUND TRANSDUCERS [J].
JENSEN, JA ;
SVENDSEN, NB .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (02) :262-267
[7]   Adaptive multi-element synthetic aperture imaging with motion and phase aberration correction [J].
Karaman, M ;
Bilge, HS ;
O'Donnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (04) :1077-1087
[8]   SYNTHETIC-APERTURE IMAGING FOR SMALL-SCALE SYSTEMS [J].
KARAMAN, M ;
LI, PC ;
ODONNELL, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (03) :429-442
[9]   Real-time 3-D ultrasound imaging using sparse synthetic aperture beamforming [J].
Lockwood, GR ;
Talman, JR ;
Brunke, SS .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (04) :980-988
[10]  
Nikolov SI, 2003, ULTRASON, P1903