Dynamic time warping applied to estimate atrial fibrillation temporal organization from the surface electrocardiogram

被引:18
作者
Alcaraz, Raul [1 ]
Hornero, Fernando [2 ]
Joaquin Rieta, Jose [3 ]
机构
[1] Univ Castilla La Mancha, Innovat Bioengn Res Grp, E-13071 Ciudad Real, Spain
[2] Gen Univ Hosp Consortium Valencia, Dept Cardiac Surg, Valencia, Spain
[3] Univ Politecn Valencia, Dept Elect Engn, Valencia, Spain
关键词
Atrial fibrillation; ECG; Fibrillatory waves regularity; Signal processing; Waveform morphology; CATHETER ABLATION; NONINVASIVE ASSESSMENT; VENTRICULAR ACTIVITY; FREQUENCY-ANALYSIS; ENTROPY; CANCELLATION; CLASSIFICATION; ELECTROGRAMS; TERMINATION; PATTERNS;
D O I
10.1016/j.medengphy.2013.03.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Atrial fibrillation (AF) is the most commonly diagnosed arrhythmia in clinical practice. However, the mechanisms responsible for its induction and maintenance still are not fully understood. To this respect, analysis of the electrical activity organization within the atria could play an important role in their proper interpretation. Although many algorithms to quantify AF organization from invasive electrograms can be found in the literature, a reduced number of indirect estimators from the standard ECG have been proposed to date. Furthermore, these surface methods can only yield a global AF organization assessment, blurring the possible information that each individual fibrillatory (f) wave may provide. To this respect, the present manuscript proposes a novel method for direct and short-time AF organization estimation from single-lead surface ECG recordings. Through the computation of morphological variations among f waves, the temporal arrhythmia organization is estimated. The f waves are individually extracted and delineated from the atrial activity signal, making use of a dynamic time warping approach. The proposed algorithm was tested on real AF surface recordings in order to discriminate atrial signals with different organization degrees, obtaining a diagnostic accuracy higher than 88%. In addition, its performance was validated by comparison with two temporal organization measures from invasive unipolar electrograms of both atria, providing statistically significant linear correlations between invasive and non-invasive estimates. As a consequence, new standpoints are opened through this work in the non-invasive analysis of AF, where the individualized study of each f wave could assess short-time AF organization, would improve the understanding of AF mechanisms and become useful for its clinical treatment. (C) 2013 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1341 / 1348
页数:8
相关论文
共 47 条
[1]   A review on sample entropy applications for the non-invasive analysis of atrial fibrillation electrocardiograms [J].
Alcaraz, R. ;
Rieta, J. J. .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2010, 5 (01) :1-14
[2]   Optimal parameters study for sample entropy-based atrial fibrillation organization analysis [J].
Alcaraz, Raul ;
Abasolo, Daniel ;
Hornero, Roberto ;
Rieta, Jose J. .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2010, 99 (01) :124-132
[3]   Adaptive singular value cancelation of ventricular activity in single-lead atrial fibrillation electrocardiograms [J].
Alcaraz, Raul ;
Rieta, Jose Joaquin .
PHYSIOLOGICAL MEASUREMENT, 2008, 29 (12) :1351-1369
[4]  
Allessie MA., 1985, Cardiac Electrophysiology and Arrhythmias, V265-76
[5]  
[Anonymous], COMPUT CARDIOL CINC
[6]   Automated classification of human atrial fibrillation from intraatrial electrograms [J].
Barbaro, V ;
Bartolini, P ;
Calcagnini, G ;
Morelli, S ;
Michelucci, A ;
Gensini, G .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (02) :192-202
[7]   Analysis of surface electrocardiograms in atrial fibrillation:: techniques, research, and clinical applications [J].
Bollmann, Andreas ;
Husser, Daniela ;
Mainardi, Luca ;
Lombardi, Federico ;
Langley, Philip ;
Murray, Alan ;
Rieta, Jose Joaquin ;
Millet, Jose ;
Olsson, S. Bertil ;
Stridh, Martin ;
Sornmo, Leif .
EUROPACE, 2006, 8 (11) :911-926
[8]   Noninvasive Assessment of the Complexity and Stationarity of the Atrial Wavefront Patterns During Atrial Fibrillation [J].
Bonizzi, Pietro ;
de la Salud Guillem, Maria ;
Climent, Andreu M. ;
Millet, Jose ;
Zarzoso, Vicente ;
Castells, Francisco ;
Meste, Olivier .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (09) :2147-2157
[9]   Corrected integral shape averaging applied to obstructive sleep apnea detection from the electrocardiogram [J].
Boudaoud, S. ;
Rix, H. ;
Meste, O. ;
Heneghan, C. ;
O'Brien, C. .
EURASIP JOURNAL ON ADVANCES IN SIGNAL PROCESSING, 2007, 2007 (1)
[10]   Descriptors of wavefront propagation - Endocardial mapping of atrial fibrillation with basket catheter [J].
Calcagnini, Giovanni ;
Censi, Federica ;
Michelucci, Antonio ;
Bartolini, Pietro .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2006, 25 (06) :71-78