A Partial Discharge-Based Health Index for Rotating Machine Condition Evaluation

被引:13
作者
Montanari, Gian Carlo [1 ,2 ]
Seri, Paolo [1 ]
机构
[1] Univ Bologna, Dept Elect Energy & Informat Engn, Bologna, Italy
[2] Univ Texas Austin, Ctr Electromech, Austin, TX 78712 USA
关键词
rotating machine; partial discharge; asset management; insulation conditions; health index; partial discharge source; condition based maintenance; ADVANCED PD INFERENCE; ON-FIELD MEASUREMENTS; ASSET MANAGEMENT; ELECTRICAL INSULATION; LIFE; IDENTIFICATION;
D O I
10.1109/MEI.2018.8300440
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It is well known that partial discharge (PD) is a threat to electrical insulation in all electrical apparatus, but we also know that PD harmfulness, and thus damage, depends on the type of defect generating the PD. As an example, having corona PD in switchgear boxes, rather than surface PD on bushings or internal PD on cable terminations, will trigger completely different actions from maintenance managers, even if the amplitude of the first (corona PD) is much larger than those of the last (internal PD). Indeed, corona PD may not need any medium- to short-term action, surface PD can just require some careful periodic checking, and internal PD in cable joints/terminations will have to be addressed promptly. © 2006 IEEE.
引用
收藏
页码:17 / 23
页数:7
相关论文
共 50 条
  • [41] Study on Thermal Aging Condition Assessment of Oil-Paper Insulation Based on Statistical Features of Partial Discharge
    Liao, Rui-jin
    Wang, Ke
    Yang, Li-jun
    Zhou, Tian-chun
    Zheng, Sheng-xun
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 325 - 328
  • [42] Condition Monitoring Based on Partial Discharge Diagnostics Using UHF Sensors: A Comprehensive State-of-the-Art Review
    Habib, Bilal
    Al Zaabi, Omar
    Harid, Noureddine
    Al Hosani, Khalifa
    Alkhatib, Mohamed
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (06) : 2860 - 2873
  • [43] Partial discharge identification using multiple features fusion based on evidence theory and support vector machine
    Xu, Yuan
    ADVANCED DESIGN AND MANUFACTURING TECHNOLOGY III, PTS 1-4, 2013, 397-400 : 2111 - 2119
  • [44] Determining Health Index of Transmission Line Asset using Condition-Based Method
    Hashim, Ruqayyah
    Usman, Fathoni
    Baharuddin, Intan Nor Zuliana
    RESOURCES-BASEL, 2019, 8 (02):
  • [45] Spectrum optimization of light-emitting diode insecticide lamp based on partial discharge evaluation
    Zhou, Jing
    Long, Xing-Ming
    Luo, Hai-Jun
    MEASUREMENT, 2018, 124 : 72 - 80
  • [46] Study on condition-based maintenance effect under uncertain health evaluation
    Yang, Shu-Ming
    Qiu, Jing
    Liu, Guan-Jun
    Xu, Yu-Guo
    Wang, Chao
    Binggong Xuebao/Acta Armamentarii, 2012, 33 (02): : 252 - 256
  • [47] Analysis of the Key Problem About Insulation Condition Assessment of Oil-paper in Power Transformers Based on Partial Discharge
    Li Q.
    Li S.
    Si W.
    Wang G.
    Wang B.
    Liu B.
    Li, Simeng (lisimeng251106@163.com), 1600, Science Press (43): : 2558 - 2565
  • [48] Evaluation technology for the operational status of overhead lines based on a health index
    Gao F.
    Liu Y.
    Jia P.
    Yang Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2024, 52 (12): : 167 - 176
  • [49] Application of Statistical Distribution Models to Predict Health Index for Condition-Based Management of Transformers
    Mohd Selva, Amran
    Azis, Norhafiz
    Shariffudin, Nor Shafiqin
    Ab Kadir, Mohd Zainal Abidin
    Jasni, Jasronita
    Yahaya, Muhammad Sharil
    Talib, Mohd Aizam
    APPLIED SCIENCES-BASEL, 2021, 11 (06):
  • [50] Application of a state space modeling technique to system prognostics based on a health index for condition-based maintenance
    Sun, Jianzhong
    Zuo, Hongfu
    Wang, Wenbin
    Pecht, Michael G.
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2012, 28 : 585 - 596