New Consistency Equation for Time-of-Flight PET

被引:11
作者
Defrise, Michel [1 ]
Panin, Vladimir Y. [2 ]
Casey, Michael E. [2 ]
机构
[1] Vrije Univ Brussel, Dept Nucl Med, B-1090 Brussels, Belgium
[2] Siemens Med Solut, Mol Imaging, Knoxville, TN 37932 USA
关键词
Image reconstruction; positron emission tomography; POSITRON-EMISSION-TOMOGRAPHY; JOHNS EQUATION; IMAGE-RECONSTRUCTION; SCANNER; PERFORMANCE;
D O I
10.1109/TNS.2012.2217507
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The redundancy in 3D time-of-flight (TOF) PET data can be exploited to reduce data storage or to estimate unmeasured data samples caused by defective or missing detectors. Mathematically, redundancy is expressed by consistency conditions which can be expressed either in terms of the 3D Fourier transform of the data or as a pair of partial differential equations (PDE). The benefit of the latter is that the PDEs are local and therefore can be applied even if some data samples are missing. This paper describes a new consistency PDE for 3D TOF PET, which only involves data within a single "segment" (data subset with fixed polar angle). The PDE is applied to rebin 3D TOF data onto 3D non-TOF data. The proposed rebinning algorithm reduces to the methods based on the most likely annihilation point in the limit where the TOF resolution tends to zero. Numerical results with simulated and phantom data illustrate the performance of the algorithm.
引用
收藏
页码:124 / 133
页数:10
相关论文
共 28 条
[11]  
John F., 1971, APPL MATH SCI
[12]   Windowed image reconstruction for time-of-flight positron emission tomography [J].
Kao, Chien-Min .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (13) :3431-3445
[13]   Variable pitch reconstruction using John's equation [J].
Karbeyaz, Basak Uelker ;
Naidu, Ram C. ;
Ying, Zhengrong ;
Simanovsky, Sergey B. ;
Hirsch, Matthew W. ;
Schafer, David A. ;
Crawford, Carl R. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (07) :897-906
[14]   CONSTRAINED FOURIER SPACE METHOD FOR COMPENSATION OF MISSING DATA IN EMISSION COMPUTED-TOMOGRAPHY [J].
KARP, JS ;
MUEHLLEHNER, G ;
LEWITT, RM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (01) :21-25
[15]   Time of flight in PET revisited [J].
Moses, WW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) :1325-1330
[16]   SENSITIVITY IMPROVEMENT OF TOFPET BY THE UTILIZATION OF THE INTER-SLICE COINCIDENCES [J].
MULLANI, N ;
WONG, W ;
HARTZ, R ;
PHILIPPE, E ;
YERIAN, K .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) :479-483
[17]  
Panin V. Y., 2010, P 2010 IEEE NUCL SCI, pM17
[18]   Consistency conditions upon 3D CT data and the wave equation [J].
Patch, SK .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (15) :2637-2650
[19]   RESULTS OF A COMPARATIVE-STUDY OF A RECONSTRUCTION PROCEDURE FOR PRODUCING IMPROVED ESTIMATES OF RADIOACTIVITY DISTRIBUTIONS IN TIME-OF-FLIGHT EMISSION TOMOGRAPHY [J].
POLITTE, DG ;
SNYDER, DL .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) :614-619
[20]   Optimal whole-body PET scanner configurations for different volumes of LSO scintillator: a simulation study [J].
Poon, Jonathan K. ;
Dahlbom, Magnus L. ;
Moses, William W. ;
Balakrishnan, Karthik ;
Wang, Wenli ;
Cherry, Simon R. ;
Badawi, Ramsey D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (13) :4077-4094