Reproducibility of Optovue RTVue Optical Coherence Tomography Retinal Thickness Measurements and Conversion to Equivalent Zeiss Stratus Metrics in Diabetic Macular Edema

被引:23
作者
Bressler, Susan B. [1 ]
Edwards, Allison R. [2 ]
Andreoli, Christopher M. [3 ]
Edwards, Paul Andrew [4 ,5 ]
Glassman, Adam R. [2 ]
Jaffe, Glenn J. [6 ]
Melia, Michele [2 ]
Sun, Jennifer K. [7 ]
机构
[1] Johns Hopkins Univ, Sch Med, Wilmer Eye Inst, Baltimore, MD 21205 USA
[2] Jaeb Ctr Hlth Res, Tampa, FL USA
[3] Harvard Med Sch, Dept Ophthalmol, Harvard Vanguard Med Associates, Boston, MA USA
[4] Henry Ford Hlth Syst, Dept Ophthalmol, Detroit, MI USA
[5] Henry Ford Hlth Syst, Eye Care Serv, Detroit, MI USA
[6] Duke Univ, Dept Ophthalmol, Durham, NC USA
[7] Harvard Univ, Dept Ophthalmol, Joslin Diabet Ctr, Beetham Eye Inst, Boston, MA 02115 USA
基金
美国国家卫生研究院;
关键词
diabetic macular edema; optical coherence tomography; retinal thickness measurements; EYES; OCT;
D O I
10.1167/tvst.4.1.5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the reproducibility of central subfield thickness (CST) and volume measurements from optical coherence tomography (OCT) images obtained with Zeiss Stratus and Optovue RTVue, and formulate equations to convert these measurements from RTVue to ` equivalent' Stratus values. Methods: Cross-sectional observational study from 309 eyes of 167 participants with diabetes and at least one eye with central-involved diabetic macular edema (DME; Stratus CST >= 250 mu m) that underwent two replicate Stratus scans followed by two replicate RTVue scans centered on the fovea. Results: The Bland-Altman coefficient of repeatability for relative change in CST (the degree of change that could be expected from measurement variability) was not significantly different on Stratus and RTVue scans (10% and 16%, respectively). The replicate Stratus CST was within 10% of the initial Stratus measurement 93% of the time; the CST conversion equation predicted a Stratus value calculated from the observed RTVue value within 10% of the observed Stratus thickness 91% of the time. Bland-Altman limit of agreement for relative change in CST between measurements observed on different machines was 23%, comparing predicted versus actual Stratus measurement. Conclusions: RTVue thickness reproducibility appears similar to Stratus. Conversion equations to transform RTVue measurements to Stratus-equivalent values within 10% of the observed Stratus RT are feasible. CST changes greater than 10% when using the same machine or 20% when switching from Stratus to RTVue, after conversion to Stratus equivalents, are likely due to a true change beyond measurement error.
引用
收藏
页数:11
相关论文
共 12 条
[1]   Transitioning from stratus OCT to cirrus OCT: a comparison and a proposed equation to convert central subfield macular thickness measurements in healthy subjects [J].
Abedi, Gelareh ;
Patal, Payal ;
Doros, Gheorghe ;
Subramanian, Manju L. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (09) :1353-1357
[2]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[3]   Reproducibility of Spectral-Domain Optical Coherence Tomography Retinal Thickness Measurements and Conversion to Equivalent Time-Domain Metrics in Diabetic Macular Edema [J].
Bressler, Susan B. ;
Edwards, Allison R. ;
Chalam, Kakarla V. ;
Bressler, Neil M. ;
Glassman, Adam R. ;
Jaffe, Glenn J. ;
Melia, Michele ;
Saggau, David D. ;
Plous, Oren Z. .
JAMA OPHTHALMOLOGY, 2014, 132 (09) :1113-1122
[4]   Repeatability of Spectralis OCT Measurements of Macular Thickness and Volume in Diabetic Macular Edema [J].
Comyn, Oliver ;
Heng, Ling Zhi ;
Ikeji, Felicia ;
Bibi, Kanom ;
Hykin, Philip G. ;
Bainbridge, James W. ;
Patel, Praveen J. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (12) :7754-7759
[5]   Randomized Trial Evaluating Ranibizumab Plus Prompt or Deferred Laser or Triamcinolone Plus Prompt Laser for Diabetic Macular Edema [J].
Elman, Michael J. ;
Aiello, Lloyd Paul ;
Beck, Roy W. ;
Bressler, Neil M. ;
Bressler, Susan B. ;
Edwards, Allison R. ;
Ferris, Frederick L., III ;
Friedman, Scott M. ;
Glassman, Adam R. ;
Miller, Kellee M. ;
Scott, Ingrid U. ;
Stockdale, Cynthia R. ;
Sun, Jennifer K. .
OPHTHALMOLOGY, 2010, 117 (06) :1064-U65
[6]   RANDOMIZEDTRIAL EVALUATING SHORT-TERM EFFECTS OF INTRAVITREAL RANIBIZUMAB OR TRIAMCINOLONE ACETONIDE ON MACULAR EDEMA AFTER FOCAL/GRID LASER FOR DIABETIC MACULAR EDEMA IN EYES ALSO RECEIVING PANRETINAL PHOTOCOAGULATION [J].
Googe, Joseph ;
Brucker, Alexander J. ;
Bressler, Neil M. ;
Qin, Haijing ;
Aiello, Lloyd P. ;
Antoszyk, Andrew ;
Beck, Roy W. ;
Bressler, Susan B. ;
Ferris, Frederick L., III ;
Glassman, Adam R. ;
Marcus, Dennis ;
Stockdale, Cynthia R. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (06) :1009-1027
[7]   Assessment of Artifacts and Reproducibility across Spectral- and Time-Domain Optical Coherence Tomography Devices [J].
Ho, Joseph ;
Sull, Alan C. ;
Vuong, Laurel N. ;
Chen, Yueli ;
Liu, Jonathan ;
Fujimoto, James G. ;
Schuman, Joel S. ;
Duker, Jay S. .
OPHTHALMOLOGY, 2009, 116 (10) :1960-1970
[8]   Spectral- and time-domain optical coherence tomography measurements of macular thickness in normal eyes and in eyes with diabetic macular edema [J].
Ibrahim, M. A. ;
Sepah, Y. J. ;
Symons, R. C. A. ;
Channa, R. ;
Hatef, E. ;
Khwaja, A. ;
Bittencourt, M. ;
Heo, J. ;
Do, D. V. ;
Nguyen, Q. D. .
EYE, 2012, 26 (03) :454-462
[9]   Conversion of Stratus optical coherence tomography (OCT) retinal thickness to Cirrus OCT values in age-related macular degeneration [J].
Krebs, Ilse ;
Hagen, Stefan ;
Smretschnig, Eva ;
Womastek, Irene ;
Brannath, Werner ;
Binder, Susanne .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (11) :1552-1554
[10]   Reproducibility of macular thickness and volume using zeiss optical coherence tomography in patients with diabetic macular edema [J].
Krzystolik, Magdalena G. ;
Strauber, Samara F. ;
Ai-ello, Lloyd Paul ;
Beek, Roy W. ;
Berger, Brian B. ;
Bressler, Neil M. ;
Browning, David J. ;
Chambers, Robert B. ;
Danis, Ronald P. ;
Davis, Matthew D. ;
Glassman, Adam R. ;
Gonzalez, Victor H. ;
Greenberg, Paul B. ;
Gross, Jeffrey G. ;
Kim, Judy E. ;
Kollman, Craig .
OPHTHALMOLOGY, 2007, 114 (08) :1520-1525