Resolving the conflict: Implantable cardioverter-defibrillator shocks for ventricular tachyarrhythmias increase mortality

被引:6
作者
Swerdlow, Charles [1 ]
Ellenbogen, Kenneth A. [1 ,2 ]
Klein, George J. [1 ,3 ]
机构
[1] Cedars Sinai Heart Inst, Los Angeles, CA USA
[2] Virginia Commonwealth Univ, Dept Cardiol, Richmond, VA USA
[3] Univ Western Ontario, Dept Cardiol, London, ON, Canada
关键词
Implantable cardioverter-defibrillator; ventricular tachyarrhythmias; PRIMARY-PREVENTION ICDS; MYOCARDIAL DYSFUNCTION; UPPER LIMIT; VULNERABILITY; INFARCTION; INTERVALS; THERAPY; INJURY; DEATH; RISK;
D O I
10.1016/j.hrthm.2011.11.039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:1328 / 1330
页数:3
相关论文
共 24 条
[1]   Complications associated with defibrillation threshold testing: The Canadian experience [J].
Birnie, David ;
Tung, Stanley ;
Simpson, Christopher ;
Crystal, Eugene ;
Exner, Derek ;
Paredes, Fetix-Alejandro Ayala ;
Krahn, Andrew ;
Parkash, Ratika ;
Khaykin, Yaariv ;
Phitippon, Francois ;
Guerra, Peter ;
Kimber, Shane ;
Cameron, Douglas ;
Healey, Jeffrey S. .
HEART RHYTHM, 2008, 5 (03) :387-390
[2]   Counterpoint: Implantable cardioverter-defibrillator shocks for ventricular tachyarrhythmias increase mortality [J].
Dorian, Paul .
HEART RHYTHM, 2012, 9 (07) :1158-1158
[3]   Mechanisms Underlying the Lack of Effect of Implantable Cardioverter-Defibrillator Therapy on Mortality in High-Risk Patients With Recent Myocardial Infarction Insights from the Defibrillation in Acute Myocardial Infarction Trial (DINAMIT) [J].
Dorian, Paul ;
Hohnloser, Stefan H. ;
Thorpe, Kevin E. ;
Roberts, Robin S. ;
Kuck, Karl-Heinz ;
Gent, Michael ;
Connolly, Stuart J. .
CIRCULATION, 2010, 122 (25) :2645-2652
[4]  
Fedorov Vadim V., 2008, V423, P433, DOI 10.1007/978-1-59745-194-9_34
[5]   A simplified biventricular defibrillator with fixed long detection intervals reduces implantable cardioverter defibrillator (ICD) interventions and heart failure hospitalizations in patients with non-ischaemic cardiomyopathy implanted for primary prevention: the RELEVANT [Role of long dEtection window programming in patients with LEft VentriculAr dysfunction, Non-ischemic eTiology in primary prevention treated with a biventricular ICD] study [J].
Gasparini, Maurizio ;
Menozzi, Carlo ;
Proclemer, Alessandro ;
Landolina, Maurizio ;
Iacopino, Severio ;
Carboni, Angelo ;
Lombardo, Ernesto ;
Regoli, Francois ;
Biffi, Mauro ;
Burrone, Valeria ;
Denaro, Alessandra ;
Boriani, Giuseppe .
EUROPEAN HEART JOURNAL, 2009, 30 (22) :2758-2767
[6]   Efficacy and temporal stability of reduced safety margins for ventricular defibrillation - Primary results from the Low Energy Safety Study (LESS) [J].
Gold, MR ;
Higgins, S ;
Klein, R ;
Gilliam, FR ;
Kopelman, H ;
Hessen, S ;
Payne, J ;
Strickberger, SA ;
Breiter, D ;
Hahn, S .
CIRCULATION, 2002, 105 (17) :2043-2048
[7]   Detection of myocardial injury during transvenous implantation of automatic cardioverter-defibrillators [J].
Hurst, TM ;
Hinrichs, M ;
Breidenbach, C ;
Katz, N ;
Waldecker, B .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (02) :402-408
[8]   Sudden death in patients with Implantable Cardioverter defibrillators - The importance of post-shock electromechanical dissociation [J].
Mitchell, LB ;
Pineda, EA ;
Titus, JL ;
Bartosch, PM ;
Benditt, DG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (08) :1323-1328
[9]   Applications of Control Theory to the Dynamics and Propagation of Cardiac Action Potentials [J].
Munoz, Laura M. ;
Stockton, Jonathan F. ;
Otani, Niels F. .
ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (09) :2865-2876
[10]  
Powell BD, 2011, HEART RHYTHM, V8, P2