Characteristics of Molybdenum as a Plasma-Generating Electrode

被引:3
作者
Lee, Sang-Heon [1 ]
Kim, Nack Hwan [1 ]
Kim, Gon-Ho [2 ]
Bae, Byeongjun [2 ]
Shin, Jun Seop [2 ]
Park, Su-San [2 ]
Yoon, Sung-Young [3 ]
Hong, Youngki [4 ]
机构
[1] Korea Univ, Dept Phys Med & Rehabil, Seoul 02841, South Korea
[2] Seoul Natl Univ, Dept Nucl Engn, Seoul 08826, South Korea
[3] Natl Fus Res Inst, Plasma Technol Res Ctr, Gunsan 54004, South Korea
[4] Cheongju Univ, Dept Sports Med, Cheongju 28503, South Korea
关键词
Plasma; Molybdenum; Metal Particles; Metal Erosion; Nucleus Pulposus; DECOMPRESSION DEVICE LDISQ; PAIN;
D O I
10.1166/sam.2016.2927
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Plasma technology is being studied and utilized in various medical fields, which requires increased ablation rate and decreased erosion rate of the metal electrode. The purpose of this experiment is to investigate the durability and the decomposition efficacy change in the catheter tips made of molybdenum metal. Metal particle size and amount in saline medium after plasma discharge were measured by electrophoretic light scattering photometry (ELS), and the tip metal surface after discharge was observed by field emission scanning electron microscopy (FESEM) and by the chemical reaction for component change. The mass defect in the tip and the decomposition rate of porcine disc by discharge time were measured by using the electric scale with a resolution of 50 mu g. The surface structure change on FESEM showed that the molybdenum tip was more intact than the stainless steel tip, and the surface components included Molybdenum 96.4 wt.%, Na 0.41 wt.%, and Cl 0.23 wt.%. The average size of the particles was 300 +/- 35 nm. At high level of electric power, the erosion rate of the molybdenum tip was about 1 ug/s. The erosion rate of the molybdenum catheter was 1x10(-13) kg per pulse, and the durability of the catheter tip was similar to that of the tungsten tip. Furthermore, we could generate plasma over 300 at the high voltage level with the molybdenum catheter. This means that the molybdenum catheter can effectively remove more tissue.
引用
收藏
页码:1844 / 1847
页数:4
相关论文
共 9 条
[1]   Mechanism of electrode erosion in pulsed discharges in water with a pulse energy of similar to 1 J [J].
Goryachev, VL ;
Ufimtsev, AA ;
Khodakovskii, AM .
TECHNICAL PHYSICS LETTERS, 1997, 23 (05) :386-387
[2]   Plasma medicine: possible applications in dermatology [J].
Heinlin, Julia ;
Morfill, Gregor ;
Landthaler, Michael ;
Stolz, Wilhelm ;
Isbary, Georg ;
Zimmermann, Julia L. ;
Shimizu, Tetsuji ;
Karrer, Sigrid .
JOURNAL DER DEUTSCHEN DERMATOLOGISCHEN GESELLSCHAFT, 2010, 8 (12) :968-976
[3]   An Assessment of a New Navigatable Percutaneous Disc Decompression Device (L'DISQ) Through Histologic Evaluation and Thermo-Mapping in Human Cadaveric Discs [J].
Hong, Young Ki ;
Derby, Richard ;
Wolfer, Lee R. ;
Kim, Sang Un ;
Kang, Bong Su ;
Kim, Nack Hwan ;
Yoo, Seung Han ;
Lee, Seok Jun ;
Lee, Sang Heon .
PAIN MEDICINE, 2012, 13 (08) :1000-1003
[4]   Plasma medicine: an introductory review [J].
Kong, M. G. ;
Kroesen, G. ;
Morfill, G. ;
Nosenko, T. ;
Shimizu, T. ;
van Dijk, J. ;
Zimmermann, J. L. .
NEW JOURNAL OF PHYSICS, 2009, 11
[5]   Effectiveness of a New Navigable Percutaneous Disc Decompression Device (L'DISQ) in Patients with Lumbar Discogenic Pain [J].
Lee, Sang Heon ;
Derby, Richard ;
Sul, Donggeun ;
Hong, Young Ki ;
Ha, Kang Wook ;
Suh, Dongwon ;
Lee, Sang Hoon ;
Yoon, Hyung Suk ;
Yoo, Seung Han ;
Lee, Seok Jun ;
Park, Hyeun Jun ;
Jung, Yong Jin ;
Lee, Jeong Eun ;
Kim, Nack Hwan .
PAIN MEDICINE, 2015, 16 (02) :266-273
[6]   Efficacy of a New Navigable Percutaneous Disc Decompression Device (L'DISQ) in Patients with Herniated Nucleus Pulposus Related to Radicular Pain [J].
Lee, Sang Heon ;
Derby, Richard ;
Sul, Dong Geun ;
Hong, Jung Wha ;
Kim, Gon Ho ;
Kang, Seok ;
Kim, Nack Hwan ;
Yoo, Seung Han ;
Lee, Seok Jun ;
Hong, Young Ki ;
Lee, Jeong Eun .
PAIN MEDICINE, 2011, 12 (03) :370-376
[7]   Focus on Plasma Medicine [J].
Morfill, G. E. ;
Kong, M. G. ;
Zimmermann, J. L. .
NEW JOURNAL OF PHYSICS, 2009, 11
[8]   Electrosurgical plasmas [J].
Stalder, KR ;
McMillen, DF ;
Woloszko, J .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2005, 38 (11) :1728-1738
[9]   Characteristics of vapor coverage formation on an RF-driven metal electrode to discharge a plasma in saline solution [J].
Yoon, Sung-Young ;
Jang, Youn Chang ;
Lee, Sang-Heun ;
Hong, Jung Wha ;
Hong, Young Ki ;
Kim, Gon-Ho .
PLASMA SOURCES SCIENCE & TECHNOLOGY, 2012, 21 (05)