Non-invasive Measurement of Valsalva-induced Hemodynamic Changes on a Bathroom Scale Ballistocardiograph

被引:19
作者
Inan, Omer T. [1 ]
Etemadi, Mozziyar [1 ]
Wiard, Richard M. [2 ]
Kovacs, Gregory T. A. [1 ]
Giovangrandi, Laurent [1 ]
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
来源
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8 | 2008年
关键词
D O I
10.1109/IEMBS.2008.4649242
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Unobtrusive and compact methods for monitoring time varying hemodynamic trends can allow physicians to monitor heart failure of outpatients at home. In this paper, the ballistocardiogram (BCG), measured on a modified commercial bathroom scale, is proposed as a viable option for this important need. The BCG measures the reaction force of the body to cardiac ejection of blood and is a non-invasive tool for evaluating cardiovascular function. The Valsalva maneuver was used to modulate the hemodynamics in a well documented manner, and BCG signals were acquired from 15 subjects. The electrocardiogram (ECG) was simultaneously obtained to measure the electrical to mechanical delay in ventricular contraction: the interval from the ECG R-wave peak to the BCG J-wave peak. This interval, called the RJ interval, decreased for all subjects following the release of intrathoracic strain compared to the resting value, suggesting that it is inversely correlated to cardiac contractility. The power spectrum magnitude of the BCGs showed that the high frequency content increased after release, also consistent with increased contractility (faster ejection). Additionally, J-wave amplitudes increased following release, suggesting that it is correlated to stroke volume. Since RJ interval computation required the ECG, BCG J-wave rise time was proposed as an alternative for evaluating cardiac contractility. The correlation between this rise time and RJ interval was high (R-2 = 0.78).
引用
收藏
页码:674 / +
页数:2
相关论文
共 17 条
  • [1] Berne RM, 2001, CARDIOVASCULAR PHYSL
  • [2] VALSALVA RESPONSES AND SYSTOLIC TIME INTERVALS DURING ANESTHESIA AND INDUCED HYPOTENSION
    BLACKBURN, JP
    CONWAY, CM
    DAVIES, RM
    ENDERBY, GEH
    EDRIDGE, AW
    LEIGH, JM
    LINDOP, MJ
    PHILLIPS, GD
    STRICKLAND, DA
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1973, 45 (07) : 704 - 710
  • [3] Ermishkin VV, 2007, IFMBE PROC, V17, P655
  • [4] Randomized trial of a daily electronic home monitoring system in patients with advanced heart failure: The Weight Monitoring in Heart Failure (WHARF) trial
    Goldberg, LR
    Piette, JD
    Walsh, MN
    Frank, TA
    Jaski, BE
    Smith, AL
    Rodriguez, R
    Mancini, DM
    Hopton, LA
    Orav, EJ
    Loh, E
    [J]. AMERICAN HEART JOURNAL, 2003, 146 (04) : 705 - 712
  • [5] PRESSURE-FLOW STUDIES IN MAN DURING VALSALVA MANEUVER WITH OBSERVATIONS ON MECHANICAL PROPERTIES OF ASCENDING AORTA
    GREENFIELD, JC
    COX, RL
    HERNANDEZ, RR
    THOMAS, C
    SCHOONMAKER, FW
    [J]. CIRCULATION, 1967, 35 (04) : 653 - +
  • [6] INAN OT, 2008, 21 IEEE INT IN PRESS
  • [7] INAN OT, ROBUST BALL IN PRESS
  • [8] Reducing the cost of frequent hospital admissions for congestive heart failure - A randomized trial of a home telecare intervention
    Jerant, AF
    Azari, R
    Nesbitt, TS
    [J]. MEDICAL CARE, 2001, 39 (11) : 1234 - 1245
  • [9] INTENSIVE HOME-CARE SURVEILLANCE PREVENTS HOSPITALIZATION AND IMPROVES MORBIDITY RATES AMONG ELDERLY PATIENTS WITH SEVERE CONGESTIVE-HEART-FAILURE
    KORNOWSKI, R
    ZEELI, D
    AVERBUCH, M
    FINKELSTEIN, A
    SCHWARTZ, D
    MOSHKOVITZ, M
    WEINREB, B
    HERSHKOVITZ, R
    EYAL, D
    MILLER, M
    LEVO, Y
    PINES, A
    [J]. AMERICAN HEART JOURNAL, 1995, 129 (04) : 762 - 766
  • [10] CRITICAL-REVIEW OF SYSTOLIC-TIME INTERVALS
    LEWIS, RP
    RITTGERS, SE
    FORESTER, WF
    BOUDOULAS, H
    [J]. CIRCULATION, 1977, 56 (02) : 146 - 158