Application of an Advanced Image-Based Virtual Monoenergetic Reconstruction of Dual Source Dual-Energy CT Data at Low keV Increases Image Quality for Routine Pancreas Imaging

被引:55
作者
Hardie, Andrew D. [1 ]
Picard, Melissa M. [1 ]
Camp, E. Ramsay [2 ]
Perry, Jonathan D. [1 ]
Suranyi, Pal [1 ]
De Cecco, Carlo N. [1 ]
Schoepf, U. Joseph [1 ]
Wichmann, Julian L. [1 ,3 ]
机构
[1] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29401 USA
[2] Med Univ S Carolina, Dept Surg, Charleston, SC 29401 USA
[3] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Frankfurt, Germany
关键词
dual-energy; monoenergetic; monochromatic; computed tomography; pancreas; LOW-TUBE-VOLTAGE; COMPUTED-TOMOGRAPHY; OPTIMIZED-PROTOCOL; HELICAL CT; CONTRAST; ADENOCARCINOMA; ABDOMEN; NOISE; RESECTABILITY; ENHANCEMENT;
D O I
10.1097/RCT.0000000000000276
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To compare image quality on contrast-enhanced dual-energy computed tomography (DECT) during the pancreatic parenchymal phase of pancreatic masses between linearly-blended simulated 120 kVp images (routine) and advanced image-based virtual monoenergetic reconstructions at 55 keV. Methods This was a retrospective evaluation of 24 nonconsecutive adults found to have a focal pancreatic mass on a multiphasic abdominal dual-source DECT (12 adenocarcinoma, 5 neuroendocrine, 7 cystic tumors). For pancreatic-parenchymal phase images, subjects had routine and 55 keV images reconstructed at the time of clinical evaluation. Quantitative evaluation by contrast-to-noise ratio and qualitative evaluations of image quality by (1) direct comparison of image pairs (preference) and (2) blinded assessment of image quality measures based on Likert scores were performed. Results Mean patient weight was 205.8 26.6 lbs. Mean pancreatic lesion contrast-to-noise ratio was significantly higher at 55 keV (6.8 +/- 4.1) compared to the routine image series (5.8 +/- 3.8; P = 0.0002). All 3 readers preferred the 55-keV images over routine blended images in 70.1% to 95.8% of cases. No significant differences were observed for subjective sharpness of the mass, visualization of internal mass structures, or image noise. Conclusions Use of a single advanced image-based virtual monoenergetic reconstruction at 55 keV in pancreatic DECT showed improved objective image quality and reader preference compared to routine images. As this image reconstruction can be incorporated into the scan protocol, this technique should be considered for routine clinical use.
引用
收藏
页码:716 / 720
页数:5
相关论文
共 22 条
[1]  
Albrecht MH, 2015, EUR RADIOL
[2]   Noise-optimized virtual monoenergetic images and iodine maps for the detection of venous thrombosis in second-generation dual-energy CT (DECT): an ex vivo phantom study [J].
Bongers, Malte N. ;
Schabel, Christoph ;
Krauss, Bernhard ;
Tsiflikas, Ilias ;
Ketelsen, Dominik ;
Mangold, Stefanie ;
Claussen, Claus D. ;
Nikolaou, Konstantin ;
Thomas, Christoph .
EUROPEAN RADIOLOGY, 2015, 25 (06) :1655-1664
[3]   Pancreatic cancer: Value of dual-phase helical CT in assessing resectability [J].
Diehl, SJ ;
Lehmann, KJ ;
Sadick, M ;
Lachmann, R ;
Georgi, M .
RADIOLOGY, 1998, 206 (02) :373-378
[4]   Pancreas: Optimal scan delay for contrast-enhanced multi-detector row CT [J].
Goshima, Satoshi ;
Kanematsu, Masayuki ;
Kondo, Hiroshi ;
Yokoyama, Ryujiro ;
Miyoshi, Toshiharu ;
Kato, Hiroki ;
Tsuge, Yusuke ;
Shiratori, Yoshimune ;
Hoshi, Hiroaki ;
Onozuka, Minoru ;
Moriyama, Noriyuki ;
Bae, Kyongtae T. .
RADIOLOGY, 2006, 241 (01) :167-174
[5]   Assessment of an Advanced Image-Based Technique to Calculate Virtual Monoenergetic Computed Tomographic Images From a Dual-Energy Examination to Improve Contrast-To-Noise Ratio in Examinations Using Iodinated Contrast Media [J].
Grant, Katharine L. ;
Flohr, Thomas G. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Thomas, Christoph ;
Schmidt, Bernhard .
INVESTIGATIVE RADIOLOGY, 2014, 49 (09) :586-592
[6]   Dual-Energy CT Applications in the Abdomen [J].
Heye, Tobias ;
Nelson, Rendon C. ;
Ho, Lisa M. ;
Marin, Daniele ;
Boll, Daniel T. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :S64-S70
[7]   MDCT of pancreatic adenocarcinoma: Optimal imaging phases and multiplanar reformatted imaging [J].
Ichikawa, Tomoaki ;
Erturk, Sukru Mehmet ;
Sou, Hironobu ;
Nakajima, Hiroto ;
Tsukamoto, Tatsuaki ;
Motosugi, Utarou ;
Araki, Tsutomu .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (06) :1513-1520
[8]   State of the Art: Dual-Energy CT of the Abdomen [J].
Marin, Daniele ;
Boll, Daniel T. ;
Mileto, Achille ;
Nelson, Rendon C. .
RADIOLOGY, 2014, 271 (02) :327-342
[9]   Detection of Pancreatic Tumors, Image Quality, and Radiation Dose during the Pancreatic Parenchymal Phase: Effect of a Low-Tube-Voltage, High-Tube-Current CT Technique-Preliminary Results [J].
Marin, Daniele ;
Nelson, Rendon C. ;
Barnhart, Huiman ;
Schindera, Sebastian T. ;
Ho, Lisa M. ;
Jaffe, Tracy A. ;
Yoshizumi, Terry T. ;
Youngblood, Richard ;
Samei, Ehsan .
RADIOLOGY, 2010, 256 (02) :450-459
[10]   Multireader evaluation of lesion conspicuity in small pancreatic adenocarcinomas: complimentary value of iodine material density and low keV simulated monoenergetic images using multiphasic rapid kVp-switching dual energy CT [J].
McNamara, Michelle M. ;
Little, Mark D. ;
Alexander, Lauren F. ;
Van Carroll, L. ;
Beasley, T. Mark ;
Morgan, Desiree E. .
ABDOMINAL IMAGING, 2015, 40 (05) :1230-1240